101 013 SJSJ YOKOGAWA, 101 013 SJSJ Datasheet - Page 4

Voltage Meter

101 013 SJSJ

Manufacturer Part Number
101 013 SJSJ
Description
Voltage Meter
Manufacturer
YOKOGAWA
Datasheet

Specifications of 101 013 SJSJ

Meter Function
DC Voltmeter
Meter Range
0-600 V
Meter Size/dimensions
DB-14
Scale Length
6.9"
Meter Shape
Square
Voltage Meter Range
0-600 VDC
Display Accuracy ±
1%
Accuracy
+/- 1% Of FS
Barrel Size
3.97"
Meter Movement
Moving Coil
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Digits 1, 2, & 3 Type
101-TB-AB/DB14
102-P&J AB/DB17
103-TB-AB/DB40
106-P&J-AB40 Synch.
120-P&J-AB16 Synch.
121-TB-AB/DB16
How to Order —
Specify the following:
1. Complete catalog number, or;
2. Provide significant portion of catalog number with word
3. Provide word description including the
Type: AB/DB-14, 16, or 40
Rating (Input):.....................Amperes AC or DC .....................
Volts AC or DC ..........................................................................
Frequency: 60 Hz, 50 Hz, 400 Hz........................................Hz
Scale: Min. Value - Max. Value, Zero left,
Zero-center or offset zero
Legend: Specify words and/or symbols exactly
Potential Transformer Ratio: ...............................to 120 volts
or ........................................to ...........................................volts
Current Transformer Ratio: ...............................to 5 amperes
or ........................................to.....................................amperes
Circuit: 2-wire/single-phase, 3-wire/3 phase.
3-phase/4-wire.................................................................other
External Devices; phase Shifting transformers, shunts
transducers, etc.........................................................................
Other Options:..........................................................................
Special features ........................................................................
description for differences (e.g. ”Similar to 103111FAFA,
except scale 0-100 kilovars”), or
following information:
103
Digits 4 & 5 Measured Qty.
01-DC Volts
02-AC Volts
07 Voltmeter (expanded scale)
11-DC Amps
12-DC Millivolts
13-AC Amps
19-Supp. Zero
21-2W1P Watts 1 EL
22-3W3P Watts 2 EL
25-4W3P Watts 2
28-3W3P Vars (cross phase) 2 EL
29-4W3P Vars (cross phase) 2
31-2W1P Vars 1 EL
32-3W3P Vars (external phase shifter) 2 EL
34-4W3P Vars (external phase shifter) 2
37-Freq. Meter
40-Power Factor 3W3P & 4W3P (balanced)
41-Power Factor 2W1P
45-Synchroscope
46-Power Factor-3W3P (unbalanced)
47-Power Factor-4W3P (unbalanced)
50-Temp. Ind.
62-DC Tach. Ind.
63-AC Tach. Ind.
70-2WIP Watts • 1 EL
71-3W3P Watts • 2 EL
73-4W3P Watts • 2
74-4W3P Vars • (cross phase) 2
76-2W1P Vars • 1 EL
77-3W3P Vars • (for use w/external phase shifter) 2 EL
79-4W3P Vars • (for use w/external phase shifter) 2
81-3W3P Vars • 2 EL (cross PH)
01
Key to AB/DB Switchboard Numbering System (See Notes)
1
2
EL
1
2
EL
1
2
1
EL
2
EL
Digit 6 Mechanical Features
1-Zero left, black cover
2-Zero center, black cover
3-Zero left, gray cover
4-Zero center, gray cover
5-Zero left, antiglare, black cover
6-Zero center, antiglare, black cover
1
2
EL
1
1
2
EL
Shipping & Storage Weights
AB-/DB-16 ...........................................................................................10 x 10 x 11 / 25 x 25 x 28
*Subtract 0.5 lbs. for plastic case amp & volt.
Approximate Package Size in Inches / Centimeters
All AB/DB
Power Factor
Frequency
Temperature
Tachometer
Synchroscope
NOTES:
1. This tabulation is not all inclusive, to be used for
2. For watt & var cat. nos. digits 7–10 & 12–14 desig-
(Except AB-/DB-16)............................................................................6 x 6 x 11 / 15 x 15 x 28
Shipping.............................................................................................7 x 7 x 13 / 18 x 18 x 33
Shipping.........................................................................................11 x 11 x 13 / 28 x 28 x 33
WATT/
defining cat. nos. only
nate rating-cal watts-scale & legend information
Digits 7 & 8 - Elec. Rtg.
Ex: LA = 1A
(see note 2)
VAR
AC
Instrument
LE = 2A
LS = 5A
DC-A/V
XX
3ø3W
3ø4W
V
A
S W I T C H B O A R D I N S T R U M E N T S
(lbs)
1.5
1.7
1.8
2.8
3.0
2.0
1.8
2.0
1.6
3.9
Digits 9 & 10 - Scale
Ex: FA = 0–1mA
(see note 2)
Net
FX = 0–5mA
(kg)
*AD/DB-40
1.3
1.4
1.8
.70
.79
.84
.95
.82
.95
.80
XX
(lbs)
2.4
2.7
2.7
3.6
3.9
3.0
2.7
3.0
2.7
4.8
Ship
(kg)
Digit 11 - Factory
Style No.
For factory use.
1.1
1.2
1.2
1.7
1.8
1.4
1.2
1.4
1.2
2.2
3. TB = taut band movement
4. P&J = pivot & jewel movement
5. “/P” suffix denotes plastic case
• Low Cal Watts, Zero Center
7
(lbs)
3.0
3.4
3.4
4.4
4.6
3.6
3.3
3.6
3.3
5.5
Net
(kg)
1.4
1.5
1.5
2.0
2.1
1.7
1.5
1.7
1.5
2.4
AD/DB-16
Digits 12, 13 &
14-Spcl Units
When used, these denote
unique models. Refer to
factory for details. For
Wattmeters & Varmeters,
see pages 11-16.
XXX
(lbs)
5.0
5.0
5.0
6.0
6.3
5.3
5.0
5.3
5.0
7.1
Ship
(kg)
2.2
2.2
2.3
2.8
2.9
2.4
2.3
2.4
2.3
3.2
3

Related parts for 101 013 SJSJ