103-111-KMKM YOKOGAWA, 103-111-KMKM Datasheet

Current Meter

103-111-KMKM

Manufacturer Part Number
103-111-KMKM
Description
Current Meter
Manufacturer
YOKOGAWA
Datasheet

Specifications of 103-111-KMKM

Meter Function
DC Milliammeter
Meter Range
0-500 MADC
Meter Size/dimensions
AB-40
Scale Length
6.9"
Current Meter Range
0-500 MADC
Accuracy
+/- 1% Of FS
Meter Shape
Square
Barrel Size
3.97"
Display Accuracy ±
1%
Rohs Compliant
NA
Lead Free Status / RoHS Status
na

Related parts for 103-111-KMKM

103-111-KMKM Summary of contents

Page 1

...

Page 2

... OKOGAWA RODUCTS CURRENT & POTENTIAL TRANSFORMERS Yokogawa CT’s and PT’s are also featured in this catalog and provide high accuracy inputs to our transformer-rated AC switchboard instruments and power transducers. Request bulletin 500CTPT-B for additional models and specifications. PANEL METERS Yokogawa has the broadest line of panel meters available today ...

Page 3

Model Type AB/DB40 AB/DB40 Case style 4 1 ⁄ ” Metal 4 1 ⁄ ” Plastic 4 4 ...

Page 4

... Vars • (cross PH) How to Order — Specify the following: 1. Complete catalog number, or; 2. Provide significant portion of catalog number with word description for differences (e.g. ”Similar to 103111FAFA, except scale 0-100 kilovars”), or 3. Provide word description including the following information: Type: AB/DB-14, 16 Rating (Input): ...

Page 5

... LSMT7/P 121 131 LSMT 103 131 LSND7/P 121 131 LSND 103 131 LSNG7/P 121 131 LSNG 103 131 LSNJ7/P 121 131 LSNJ 103 131 LSNL7/P 121 131 LSNL 103 131 LSNP7/P 121 131 LSNP 103 131 LSNT7/P 121 131 LSNT ...

Page 6

... PZUY 101 023 PZWZ 103 021 PZWZ 101 023 PZXE 103 021 PZXE 101 023 PZXU 103 021 PZXU 101 023 PZYR 103 021 PZYR 101 023 RSSJ 103 021 RSSJ ** 103 071 PNPN ** 103 071 103 021 PZPZ ** 103 021 PZ ...

Page 7

... CANG 103 121 CANG7/P 101 123 CANL 103 121 CANL 103 121 CANL7/P 101 123 CANP 103 121 CANP 103 121 CANP7/P 101 123 CANT 103 121 CANT 103 121 CANT7/P 101 123 CAPB 103 121 CAPB 103 121CAPB7/P ...

Page 8

... SFSF7/P 103 011 SJSJ 103 011 SJSJ7/P 103 012 PZPZ 103 012 PZPZ7/P 103 012 RXRX 103 012 RXRX7/P 103 012 SFSF 103 012 SFSF7/P 103 012 SJSJ 103 012 SJSJ7/P 103 012 PZ† 103 012 PZ†7/P 103 012 RX† ...

Page 9

AB/DB17 Switchboard Meters GENERAL SPECIFICATIONS BASIC SPECIFICATION In accordance with American National Standards Institute Specifications C39.1 SCALE LENGTH ...

Page 10

... AB-40 Cat. No. AB-16 Cat. No. 103 372 AGAG 121 372 AGAG 103 372 AJAJ 121 372 AJAJ 103 372 AKAK 121 372 AKAK 103 372 ALAL 121 372 ALAL 103 372 ANAN 121 372 ANAN 103 372 ATAT 121 372 ATAT ...

Page 11

... A …… † 103 25 C …… Scale AB-40 Cat. No. † 103 31 A …… † 103 762 A ……* Cannot be used with External Phase Shifter) † 103 28 A † 103 812 A ……• † 103 32 A …… † ...

Page 12

A PPLICATION 1. For polyphase applications, see Selector Tables II-V. These tables display complete catalog numbers for use with com- monly used combinations of CT and PT ratios. For single phase applications, order by description. For 3-wire 3-phase wattmeters rated ...

Page 13

... Calibrating Watts/Element = Desired full-scale value in watts or vars CW (PT Ratio) x (CT Ratio Where for 1-phase/2-wire circuits for 1-phase/3-wire, 2-phase/3-wire, 2-phase/4-wire, 3 phase/3-wire circuits for 3-phase/4-wire circuits Except K = 1.1547 for var models (10328 — & 103812 — 10329 — & 103742 — PRIMARY VOLTAGE 480 600 2400 ...

Page 14

...

Page 15

...

Page 16

...

Page 17

...

Page 18

Optional Features for AB/DB 40, AB/DB 16 Scales 1. Uncalibrated 2. Special marked scales 3. Special legends 4. Colored markings, lines or arcs other than black. 5. Fine line marking (approximately twice the normal calibration marks — maximum 150 calibration ...

Page 19

Minimum and Maximum Ratings For AB/DB 40, AB/DB 16 Indicator AC Voltmeter AC Ammeter AC Milliammeter AC Wattmeter ...

Page 20

Specifications, Burden Data — AC Meters Type Impedance in Ohms 120-Volt, 60-Hertz Potential Circuit Voltmeters, AB-16/ 28,100 Expanded-scale Voltmeters . . . . . . 15,400 Single phase Wattmeters* AB-16/40 ...

Page 21

... NOTE: UL requires a separate grounding terminal that is provided above a ground symbol ( Connection diagrams for AB/DB16 and AB/DB14 Ammeters and Voltmeters are same as AB/DB40 depicted above Ammeter 103131xxxx AC Voltmeter 103021xxxx AC Voltmeter 103021xxxx7xxx DC Ground Detector DC Ammeter 10311-xxxx DC Ammeter 10312-xxxx DC Voltmeter 10301-xxxx Temperature Indicator 103502xxxx ). ...

Page 22

... V) 10329-xxxx7xxx 1.1547 103742xxxx7xxx See Note 1. Page 12 Phase Sequence 1-2-3 Connections for 2 ⁄ element 1 2 varmeter used to measure vars wire, 3 phase circuit ...

Page 23

... NOTE: UL requires a separate grounding terminal that is provided above a ground symbol ( 22 Single-phase power-factor meter with current transformer and potential transformer 103412xxxx Frequency Meter with potential transformer 103372xxxx Phase Sequence 1-2-3 Three-wire, three-phase power- factor meter with current transformer and potential transformers (Balanced System) 103402xxxx Synchroscope with potential transformers 106452xxxx ). ...

Page 24

... E 4.09 4.09 F 4.33 4.33 H — 8.06 *Short case dimensions in first column above apply to varmeter for use with external phase shifters (10332—, 10377—, 10334—, 10379—.) AB/ DB- — Power Factor Frequency Power Factor 1 Temperature 1 (3 3w/4w) Tachometer (3 3w/4w) 3 ...

Page 25

Plastic case AB / DB40 Ammeters and Voltmeters High shock AB / DB14 Ammeters and Voltmeters Illuminated ...

Page 26

Specifications Accuracy Class: Standard — ± 1.5% of full-scale span for DC horizontal and vertical and AC horizontal. ± 2% for AC vertical. Suppressed zero (mechanical) — ± full scale span. AC Rectifier-type Ammeters and Voltmeters— Standard ± ...

Page 27

AMMETERS D’ARSONVAL TYPE Scale Terminal ±1.5% and Resistance, Accuracy Rating Ohms Vertical DC AMMETERS — SELF-CONTAINED 0–50µA ...

Page 28

Type 180 Optional Features Scale Variations 1. Blank Scales 2. Special marked scales (maximum 100 divisions; Ref. Notes 3 and 4) 3. Special Legends (Ref. Notes 3 and 4) 4. Colored markings, lines, bars, etc. 5. Black scale with white ...

Page 29

... Frequency 115V or 45-55 Hz, 55-65 Hz Meters 230V 45-66 Hz Rating Available *Instrument is furnished with external transducer. Contact Yokogawa for transducer outline and connection drawings. 28 Miniature Switchboard Instruments — 2180 Series GENERAL SPECIFICATIONS Terminal Plate: Phenol resin, black Mounting Screw: 5mm dia. Measuring Terminal: 5mm dia (nut type) Operating Temperature Range 40º ...

Page 30

S Example: 218100-AFA- 0-1mA rating & scale with black cover DC Ammeters and Voltmeters Model Number Suffix Rating and scale 2181 00- Full scale value AEM- 500 µADC (zero left) AFA- 1mADC AFG- 2mADC AHF- 20mADC AKM- ...

Page 31

POWER SERIES POWER SERIES Plus fills the need for a high accuracy digital switch- board meter and transducer ...

Page 32

GENERAL SPECIFICATIONS — POWER SERIES DISPLAY Type: Digit height: Decimal points: Out of range indication: Response time: AUXILIARY Choice of inputs at POWER rear terminal board INPUT Current: RATING Voltage: Frequency: INPUT RANGE Rated current: Rated voltage: SUSTAINED Rated current: ...

Page 33

POWER SERIES Plus SELECTOR GUIDE AC WATTS, VARS, POWER FACTOR AND PHASE ANGLE 1 2 MODEL FORMAT: 2491 ...

Page 34

POWER SERIES TERMINAL CONNECTIONS Plus ...

Page 35

... Yokogawa’s JUXTA“AC POWER SERIES“ transducers (2469 & 2489) are rugged metal case designs for utility and industrial applica- tions. Most models are UL recognized under File E60579 and exceed IEEE472/ANSI C37.90.1 Surge Withstand Capability test. The “SWC” test assures maximum protection from damaging line tran- sients caused by switchgear operation or lightning strikes upstream on the system ...

Page 36

JUXTA POWER TRANSDUCERS Standard transducer inputs / outputs 120V, 5A AC, 60 Hz, Input powered W Watt/Var 1P2W, 0 ± 1mA output (1 Element) A Watt/Var 1P2W 20mA output (1 Element)* T Watt/Var 3P3W, 0 ± 1mA output ...

Page 37

... Some transformers will have 3 MSD (ex. 125:5). The multiplier will go after the third digit. An example of a 125 2RL-1250 RL Notes: (1) Yokogawa Current and Potential Transformers are component recognized under UL E93779 and CSA LR89403 (2) All CT’s are insulation class 0.6kV, BIL 10kV full wave. Frequency 50 - 400 Hz. ...