MCJR1S00 DANAHER, MCJR1S00 Datasheet - Page 100

Multifunction Counter

MCJR1S00

Manufacturer Part Number
MCJR1S00
Description
Multifunction Counter
Manufacturer
DANAHER
Datasheet

Specifications of MCJR1S00

No. Of Digits / Alpha
8
Digit Height
7.6mm
Power Consumption
6VA
Counting Speed
10kHz
Operating Temperature Range
0°C To +50°C
Character Size
0.3"
Panel Cutout Width
3.58"
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
5.06
The Eagle Signal brand Series HP5E CYCL- FLEX timer is a modern,
microprocessor based reset timer housed in the standard CYCL- FLEX
plug-in enclosure. Timing progress is indicated by a LED array that
displays remaining time interval. Its 5.20 inches circumference
calibrated dial is easy-to-read with well defined resolution increments on
all ranges. The 15 terminal ABS (U. L. rated 94V- 0) molded housing
has high impact resistance and will not support combustion.
SPECIFICATIONS
Time Ranges
Reset Time: 500 mS at maximum setting
Voltage/ Frequency:
120 V (+10 -15%) 50/60 Hz
240 V (+10 -15%) 50/60 Hz
Power Consumption: 1.5 watts
Contact Rating:
10 Amps Resistive / Inductive @ 120vAC 1/6 HP @ 120VAC
5 Amps Resistive / Inductive @ 240VAC 1/2 HP @ 240VAC
Electrical Contact Lifetime: Average, contingent on load characteris-
tics. Inrush current should not exceed 10 amps.
At full load: 250,000 cycles
At 1 amp load: 5 million cycles
Sym.
16 standard time ranges from 5 seconds to 60 hours
Knob adjustable time ranges and LED progress indicator
Pilot light indicates when timer is active
Optional reverse action mode will not reset on power failure
15 terminal ABS (UL rated 94V-0) molded housing has high impact
resistance and will not support combustion
EAGLE SIGNAL
17
15
14
18
10
11
0
1
2
3
4
5
6
7
8
9
Electronic Timers
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
150 Sec.
150 Min.
10 Sec.
15 Sec.
30 Sec.
60 Sec.
10 Min.
15 Min.
30 Min.
60 Min.
5 Sec.
5 Min.
10 Hr.
30 Hr.
60 Hr.
Dial
5 Hr.
Minimum
Setting
1/5 Sec.
1/5 Sec.
1/2 Sec.
12 Sec.
12 Min.
12 Min.
12 Sec
1 Sec.
1 Sec.
5 Sec.
1 Min.
1 Min.
1 Min.
5 Min.
1 Hr.
1 Hr.
Divisions
1/5 Sec.
1/5 Sec.
1/2 Sec.
12 Sec.
12 Sec.
12 Min.
12 Min.
1 Sec.
1 Sec.
5 Sec.
1 Min.
1 Min.
1 Min.
5 Min.
1 Hr.
Dial
1Hr.
brand
Accuracy
Repeat
.05 Sec.
.05 Sec.
.08 Sec.
1.5 Sec.
7.5 Sec.
4.5 Sec.
1.5 Min.
15 Sec.
18 Sec.
45 Sec.
18 Min.
3 Sec.
2 Sec.
9 Sec.
3 Min.
9 Min.
HP5E CYCL-FLEX
OPERATION (reference Schmatic Diagram)
Standard: Instantaneous contacts 9-10-C and 6-7-8 operates directly
with power applied to 1, 11(E) and 2. Different operating sequences are
possible depending on the control circuit configuration.
Delayed contacts 4- 3 and 11- A close and contacts 4- 5 and 11- 12
open when timer reaches a timed out condition. Contacts 4- 5 and 11-
12 close and contacts 4- 3 and 11- A open when timer is reset.
Reverse Start: Instantaneous contacts 9-10-C and 6-7-8 operates
directly with power applied to 1, 11(E) and 2. Different operating
sequences are possible depending on the control circuit configuration.
Delayed contacts 4- 3 and 11- A close and contacts 4- 5 and 11- 12
open when timer reaches a timed out position. Contacts 4- 5 and 11- 12
close and contacts 4- 3 and 11- A open when timer is reset.
Power On Response:
28 ms average pull-in
17 ms average drop-out
Operationg Temerature: -10 to +140 F (-23 to +60 C)
Approximate weight: 1.7 lbs.
Agency Approvals: FM; UL/CUL Recognition
Modern, high quality timer
housed in industry standard
patented plug-in housing
1
9
6
STANDARD
Factory Wiring
C
7
10
8
CRI
11
4
2
E
Schematic Diagram
5
12
A
3
®
File No. E61735
C
Reset Timer
®
US
E61735
CRI
1
9
6
REVERSE
Factory Wiring
C
7
10
8
A P P R O V E D
11
4
F M
2
E
5
12
A
3

Related parts for MCJR1S00