E5AN-R3HMT-500-N AC100-240 Omron, E5AN-R3HMT-500-N AC100-240 Datasheet - Page 14

Digital Temperature Controller

E5AN-R3HMT-500-N AC100-240

Manufacturer Part Number
E5AN-R3HMT-500-N AC100-240
Description
Digital Temperature Controller
Manufacturer
Omron

Specifications of E5AN-R3HMT-500-N AC100-240

No. Of Digits / Alpha
4
Meter Function
Temperature
Meter Range
-200°C To +2300°C
Digit Height
15.8mm
Power Consumption
10VA
Operating Temperature Range
-10°C To +55°C
No. Of Outputs
3
Supply Voltage Range
100VAC To 240VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Waterproof Packing
Y92S-P4 (for DIN 96 × 96)
Current Transformers
E54-CT1
E54-CT3
E54-CT3 Accessory
Approx. 3 dia.
Approx. 6 dia.
• Armature
• Plug
(22)
18
25
40 × 40
15
10
3
Connection Example
Y92S-P5 (for DIN 48 × 96)
Plug
40
30
30
15
30
21
5.8 dia.
Two, M3 (depth: 4)
12 dia.
Two, 3.5 dia.
10.5
Armature
2.36 dia.
2.8
Lead
7.5
9
Order the Waterproof Packing separately if it becomes lost or
damaged.
The Waterproof Packing can be used to achieve an IP66 degree of
protection.
(Deterioration, shrinking, or hardening of the waterproof packing may
occur depending on the operating environment. Therefore, periodic
replacement is recommended to ensure the level of waterproofing
specified in IP66. The time for periodic replacement depends on the
operating environment. Be sure to confirm this point at your site.
Consider one year a rough standard. OMRON shall not be liable for
the level of water resistance if the customer does not perform periodic
replacement.)
The Waterproof Packing does not need to be attached if a waterproof
structure is not required.
E54-CT1
Thru-current (Io) vs. Output Voltage
(Eo) (Reference Values)
Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400±2
Winding resistance: 18±2 Ω
E54-CT3
Thru-current (Io) vs. Output Voltage
(Eo) (Reference Values)
Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for an OMRON
Temperature Controller is 50 A.)
Number of windings: 400±2
Winding resistance: 8±0.8 Ω
100 mV
100 mV
100 µV
100 µV
100 V
100 V
10
10
10
10
10
10
1
1
1
1
1
1
50 Hz
50 Hz
10
10
100 mA
100 mA
500 Ω
1 kΩ
1 kΩ
E5AN/E5EN
1
1
R
100 Ω
Thru-current (Io) A (r.m.s.)
Thru-current (Io) A (r.m.s.)
L
= 10 Ω
50 Ω
R
100 Ω
10
L
10
= 10 Ω
1%
3%
Distortion
factor 10%
100 1,000 A
100 1,000 A
1%
3%
Distor-
tion
factor
10%
14