E5AN-R3HMTC-500 AC/DC24 Omron, E5AN-R3HMTC-500 AC/DC24 Datasheet

Temperature Meter

E5AN-R3HMTC-500 AC/DC24

Manufacturer Part Number
E5AN-R3HMTC-500 AC/DC24
Description
Temperature Meter
Manufacturer
Omron
Datasheet

Specifications of E5AN-R3HMTC-500 AC/DC24

No. Of Digits / Alpha
4
Meter Function
Temperature
Meter Range
-200°C To +1300°C
Digit Height
15mm
Power Consumption
4W
Operating Temperature Range
-10°C To +55°C
Controller Output Type 1
Voltage/SSR
Supply Voltage Range
24 VAC/VDC
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Ordering Information
Compact 1/4 DIN Size Controllers
D
D
D
D
D
D
D
D
J Temperature Controllers
Stock Note: Shaded models are normally stocked.
Optional communications and event input boards are shown on the following page.
Note: When the heating/cooling function or the heater burnout alarm is used, one of the alarm outputs is disabled for each function used.
A--76
1/4 DIN
96(W)
96(W) x
96(H) x
96(H) x
78(D) mm
78(D) mm
/
E5AN
Reduced panel depth of only 78 mm.
Accepts thermocouple, platinum RTD, non-contact
temperature sensors and analog temperature inputs.
Auto-tuning and self-tuning available; functions can be
used simultaneously.
Heating or heating/cooling control.
Event input option allows multiple set point selection
and Run/Stop function.
Water-resistant construction (NEMA 4X, equivalent to
IP66).
Conforms to UL, CSA and IEC safety standards as well
as CE marking.
3-year warranty.
Digital Temperature Controller
Size
Digital Temperature Controller
100 to 240
VAC
VAC
24 V
AC/DC
AC/DC
supply
supply
voltage
Power
points
points
3
3
Alarm
Relay
Voltage (for
d i i
driving SSR)
Current
Relay
Voltage (for
d i i
driving SSR)
Current
Output
y
y
g (
g (
SSR)
SSR)
E5AN
No
Yes
No
Yes
No
No
Yes
No
Yes
No
burnout
burnout
Heater
alarm
E5AN-R3MTC-500 AC100-240
E5AN-R3HMTC-500 AC100-240
E5AN-Q3MTC-500 AC100-240
E5AN-Q3HMTC-500 AC100-240
E5AN-C3MTC-500 AC100-240
E5AN-R3MTC-500 AC/DC24
E5AN-R3HMTC-500 AC/DC24
E5AN-Q3MTC-500 AC/DC24
E5AN-Q3HMTC-500 AC/DC24
E5AN-C3MTC-500 AC/DC24
Thermocouple input
Model
E5AN-R3MP-500 AC100-240
E5AN-R3HMP-500 AC100-240
E5AN-Q3MP-500 AC100-240
E5AN-Q3HMP-500 AC100-240
E5AN-C3MP-500 AC100-240
E5AN-R3MP-500 AC/DC24
E5AN-R3HMP-500 AC/DC24
E5AN-Q3MP-500 AC/DC24
E5AN-Q3HMP-500 AC/DC24
E5AN-C3MP-500 AC/DC24
Platinum RTD input

Related parts for E5AN-R3HMTC-500 AC/DC24

E5AN-R3HMTC-500 AC/DC24 Summary of contents

Page 1

... No E5AN-R3MTC-500 AC100-240 Yes E5AN-R3HMTC-500 AC100-240 No E5AN-Q3MTC-500 AC100-240 SSR) Yes E5AN-Q3HMTC-500 AC100-240 No E5AN-C3MTC-500 AC100-240 No E5AN-R3MTC-500 AC/DC24 Yes E5AN-R3HMTC-500 AC/DC24 No E5AN-Q3MTC-500 AC/DC24 SSR) Yes E5AN-Q3HMTC-500 AC/DC24 No E5AN-C3MTC-500 AC/DC24 E5AN Model Platinum RTD input E5AN-R3MP-500 AC100-240 E5AN-R3HMP-500 AC100-240 E5AN-Q3MP-500 AC100-240 E5AN-Q3HMP-500 AC100-240 E5AN-C3MP-500 AC100-240 ...

Page 2

... The indication of R and S thermocouples at a temperature of 200°C or less is ±3°C±1 digit maximum. Specifications 24 VAC, 50/60 Hz/24 VDC 5 VA/4 W +15% / (PNP), max. load current: 40 mA, with short-circuit protection circuit --20% (This table continues on the next page.) Digital Temperature Controller Model E53-AK01 E53-AK03 E53-AKB E54-CT1 E54-CT3 E53-COV11 Thermo Tools (See Note) E5AN A--77 ...

Page 3

... Interface (See Note 1) Retry function Communications buffer Note: 1. RS-232C communications are only supported for the E5AN and E5EN models. 2. The baud rate, data bit length, stop bit length, or vertical parity can be individually set using the communications setting level. J Current Transformer Ratings Model Max ...

Page 4

... K60 to K115 to K160 120°C 165°C 260° -1999 to 9999 or to 165 to 260 -199.9 to -199.9 to 999 (selectable) 320 500 JPt100 JPt100 3 4 --199.9 to 500.0 0.0 to 100.0 --199.9 to 900.0 0.0 to 210.0 E5AN A--79 ...

Page 5

... Controllers when they are group +0 mounted.) (3.62) • To mount the E5AN so that it is waterproof, apply the waterproof packing to the E5AN. • When two or more E5ANs are mounted, make sure that the surrounding temperature does not Group mounting does not allow waterproofing. ...

Page 6

... Input power supply Control output 1 Heater burnout detection input ALM3/Control output 2 ALM2 OR output of ALM1/Heater burnout Digital Temperature Controller 2.36 (0.09) dia. 30 (1.18) 12 dia. 9 (0.35) x Two, M3 (depth (1.18) Event input Non-contact input Communications RS--232C RS--485 Don’t use Analog input E5AN A-- ...

Page 7

...

Page 8

Cat. No. H301-E3-1 6/04 Specifications subject to change without notice Printed in USA ...