INFS-0200-DC1 NEWPORT ELECTRONICS, INFS-0200-DC1 Datasheet - Page 55

Strain Gauge Meter

INFS-0200-DC1

Manufacturer Part Number
INFS-0200-DC1
Description
Strain Gauge Meter
Manufacturer
NEWPORT ELECTRONICS
Datasheet

Specifications of INFS-0200-DC1

No. Of Digits / Alpha
6
Meter Range
0mV To 100mV
Digit Height
13.7mm
Power Consumption
6W
Operating Temperature Range
0°C To +50°C
Signal Input Type
0 To 100mV Voltage
Lead Free Status / RoHS Status
na
If the nonzero reading is fluctuating between two numbers, convert
the smaller count value to the offset value, then add a 5 just right
of the decimal point. This adds half a count to the offset. For
example, the display if flucuating between 00.0001 and 00.0002.
Calculate the offset using the 000001 count value. The converted
offset value is -1.0000. Add a 5 to the right of the decimal point:
the final offset value is -1.5000.
PRESS
‘MENU’
‘MIN’
‘MIN’
‘MENU’
‘RESET’ ‘RESET’
THEN PRESS
(TO CHANGE DISPLAY
IF REQUIRED) SHOWS
‘MAX’
8-11
“RESET2”
UNTIL
“RDG OF”
“000000.”
“XXXXXX”
“STORED”
then
“IN CNF”
the then
Measured
Value
COMMENTS
Press the ‘MENU’
button until the display
shows “RDG OF”.
Press the ‘MIN’
button and the display
will show the last
offset entered.
Use the ‘MIN’ to
move to each digit and
the ‘MAX’ button to
change the flashing
digits value and enter
your zero offset
number.
Press the ‘MENU’
button to store
your selection. The
display will momen-
tarily show “STORED”
then “IN CNF”.
Press the ‘RESET’
button two times. The
display will momen-
tarily show “RESET2”
and then will display
the currently
measured values.
Scaling to
Display
Engineering
Units
8