EMC 1500 LASCAR, EMC 1500 Datasheet - Page 2

Digital Hour Meter

EMC 1500

Manufacturer Part Number
EMC 1500
Description
Digital Hour Meter
Manufacturer
LASCAR
Datasheet

Specifications of EMC 1500

Character Size
0.35"
Height
0.84"
Time Range Min
0.1h
Meter Function
Hourmeter
Width
1.7"
Accuracy
+/- 6 Seconds/24 Hours
Supply Voltage Max
27VDC
Time Range Max
99999h
No. Of Digits / Alpha
5
Lead Free Status / RoHS Status
na
TOTAL
WIRE FUNCTIONS
0. Black
1. Brown
2. Red
3. Orange V-SENSE
4. Yellow
5. Green
6. Blue
7. Violet
Warning :
DISPLAY FUNCTIONS
8888.8
TRIP
- - - - - - - - - -
Specifications liable to change without prior warning
APPLICATIONS
0V
RANGE
V+
PULSE
LZB
RESET
TRIP/TOTAL
The 5 digit readout displays elapsed time in hours.
This symbol is displayed when trip mode is selected (see Wire Functions above)
This symbol is displayed when total mode is selected (see Wire Functions above)
The 10-segment incrementing bar indicates that the module is working correctly and counting hours.
Basic 3-wire operation:
Open S1 to read TOTAL value
without counting hours.
9999.9 Hour range
- 99999 Hour range
- Leading Zeros are displayed
- Timing in TOTAL mode
- Leading Zeros are displayed
- Timing in TRIP mode
Do not connect the following wires to V+: RANGE, PULSE, LZB, RESET, TRIP/TOTAL, as this may
damage the meter. The user must incorporate suitable protection circuitry in applications where
the voltage to any of the meter's wires can exceed 27V d.c., including transient conditions, else
damage to the meter may occur. In particular, for applications in harsh electrical environments,
e.g. automotive, suitable external protection must be provided to protect against "load dump"
conditions, transients, etc.
TRIP
TEL: +44 (0)1794 884567 FAX: +44 (0)1794 884616
Black
-
Orange
MODULE HOUSE, WHITEPARISH,
LASCAR ELECTRONICS LTD.
TOTAL
Negative power supply connection.
Do not connect for 99999 Hour range.
Connect to 0V for 9999.9 Hour range.
Positive power supply connection.
Connect to V+to start/continue counting elapsed hours.
Connect to 0V or do not connect to read TRIP or TOTAL value without counting elapsed hours.
Normally at 0V, this output goes High (+3.3V) every hour in the selected mode.
Do not connect to display leading zeros.
Connect to 0V to blank all leading zeros.
When reading is 0000.0 or 00000, leading zeros are not blanked.
Connect momentarily to 0V to reset the display to zero (internally connected to V+ via pull-up resistor).
Do not connect for TOTAL mode operation. In TOTAL mode, the elapsed hour meter cannot be reset to zero.
Connect to 0V for TRIP mode operation. In TRIP mode, the elapsed hour meter can be reset to zero.
Red
Black
E-mail: sales@lascar.co.uk
Brown
WILTSHIRE SP5 2SJ UK
0V
-
Red
S1
Hrs
Hrs
Orange
Violet
V+
0V
V+
EMC 1500
TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141
E-mail: us-sales@lascarelectronics.com
Issue 10
LASCAR ELECTRONICS INC.
3750 West 26th Street,
Erie, PA 16506 USA
November/2006
Leading zeros blanked.
Close S1 to select TRIP mode.
Using the PULSE O/P to drive an LED.
The LED will illuminate once after every hour.
TRIP
-
IRCN 0539
Orange
Black
Black
Orange
HOW MING STREET, KWUN TONG, KOWLOON, HONG KONG
TOTAL
Green
Red
-
UNIT NOS. 6-8, 19/F FUTURA PLAZA,111-113
Brown
TEL: +852 2389 6502 FAX: +852 2389 6535
LASCAR ELECTRONICS (HK) LIMITED
Red
Hrs
Hrs
S1
E- mail:
M.C.
Violet
Violet
V+
0V
purchasing@lascar.com.hk
Applies to EMC 1500/3
Yellow
No: 716 - Page 2 of 2
R
V+