Specifications of H3AM-NS-B300

Time Range
1sec To 60 Hr
Power Consumption
9VA
Reset Time
0.5s
Supply Voltage Ac, Min
100V
External Width
96mm
External Depth
85mm
Height
96mm
Supply Voltage Ac, Max
240V
Carry Current
5A
Approval Bodies
CSA / UL
Operating Temperature Max
55°C
H3AM
Note: A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
EMC
Enclosure rating
Weight
Characteristics
The H3AM-NSj-j-300 model with waterproof packing is available.
Power reset: 0.5 s max.
Reset input time: 0.5 s max.
100 M max. (at 500 VDC)
2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and
current-carrying metal parts
2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals
1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit
1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other
2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles
3 kV between power terminals
4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts
(pulse width: 100 ns/1 s, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude
Destruction: 300 m/s
Malfunction: 150 m/s
Mechanical: 5,000,000 times min. (under no load at 1,800 times/h)
Electrical:
(EMI):
Emission Enclosure:
Emission AC Mains:
(EMS):
Immunity ESD:
Immunity RF-interference:
Immunity Power Frequency Magnetic Fields:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
IP65 (front panel only) (see note) IP20 (terminal section)
Approx. 350 g
0.7% FS max.
2% FS max.
1% FS max.
2% FS max.
1.5 kV (between power terminals) square-wave noise by a noise simulator
100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)
2
2
(approx. 30G)
(approx. 15G) (100 m/s
50081-2
EN55022 class A
EN55022 class A
50082-2
EN61000-4-2: 4 kV contact discharge (level 2)
ENV50140:
ENV50204:
EN61000-4-8: 30 A/m (50 Hz) (level 4)
ENV50141:
EN61000-4-4: 2 kV power-line (level 3)
EN61000-4-5: 1 kV line to line
2
(approx. 10G) in the front/back direction)
8 kV air discharge (level 3)
10 V/m (80 MHz to 1 GHz) (level 3)
10 V/m (900 MHz 5 MHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV I/O signal-line (level 4)
2 kV line to ground (level 3)
(H3AM-NSR only)
H3AM
3