H5CX-L8D-N AC24/DC12-24 Omron, H5CX-L8D-N AC24/DC12-24 Datasheet - Page 32

Digital Multifunction Timer

H5CX-L8D-N AC24/DC12-24

Manufacturer Part Number
H5CX-L8D-N AC24/DC12-24
Description
Digital Multifunction Timer
Manufacturer
Omron
Datasheet

Specifications of H5CX-L8D-N AC24/DC12-24

Time Range
0.001s-9999hrs
Power Consumption
2.4W
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
12V
Connector Type
8-Pin Socket
Signal Input Type
PNP/NPN
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
32
H5CX-A@-N/-L@-N
Key Protect Level
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-7).
The key protect indicator is lit while the key-protect switch is set to ON.
* Changing mode to Timer/Twin Timer Selection Mode or Function Setting Mode.
Self-diagnostic Function
The following displays will appear if an error occurs.
*1. This includes times when the life of the EEPROM has expired.
*2. The normal display and
(default setting)
When the Reset Key is pressed,
continue without clearing the output ON count.)
Main display
Level
KP-1
KP-2
KP-3
KP-4
KP-5
KP-6
KP-7
e1
e2
e2
e3
*2
e3
Sub-display
No change
will appear alternately.
Not lit
Not lit
sum
e3
Meaning
* Factory-set to OFF
will no longer be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the Timer will
CPU
Memory error (RAM)
Memory error EEPROM
Output ON count alarm set
value exceeded
(Disabled)
OFF
*
Key protect indicator
Error
Changing mode*
(Enabled)
ON
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
*1
Output status
No change
OFF
OFF
OFF
Switching display
during operation
Invalid
Invalid
Invalid
Valid
Valid
Valid
Valid
Either press the reset key or
reset the power supply.
Reset the power supply.
Reset Key
Reset Key
Details
Correction method
Reset Key
Invalid
Invalid
Invalid
Invalid
Valid
Valid
Valid
Set value after reset
Factory setting
Up/down key
No change
No change
No change
Invalid
Invalid
Invalid
Valid
Valid
Valid
Valid

Related parts for H5CX-L8D-N AC24/DC12-24