CP1LSTARTERKITAC Omron, CP1LSTARTERKITAC Datasheet - Page 3

no-image

CP1LSTARTERKITAC

Manufacturer Part Number
CP1LSTARTERKITAC
Description
STARTER KIT
Manufacturer
Omron
Datasheet

Specifications of CP1LSTARTERKITAC

Accessory Type
Starter Kit
External Width
86mm
Svhc
No SVHC (15-Dec-2010)
External Depth
85mm
External Length / Height
90mm
Input
4 X Encoder, 4 X Interrupts/Counters
For Use With
CP1L Compact Machine Controller
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
When it comes to controllers for compact machines,
Omron's new CP1L series offers the compactness of
a micro-PLC with the capability of a modular PLC.
But this new and exciting range is not only compact, it
is scaleable, has a faster processing speed than other
controllers and is in a class of its own when it comes
to price/performance. Naturally, it is compatible with
all other devices in the Omron PLC line up.
• 4 high-speed encoder inputs and 2 high-speed
• CPUs with AC or DC supply and 14, 20, 30 or
• Instruction set compatible with CP1H-, CJ1-,
• Optional RS232C and RS-422A/485 serial ports
• USB programming port
• Scaleable with a wide range of I/O units
• Motion functionality
• One and the same software as other Omron
Note: The above values are for a cold start at room temperature for an AC power supply, and for a cold start for a DC power supply.
CPU Units and Expansion Units
CPU Unit Specification
Item
Power supply
Operating voltage range
Power consumption
Inrush current (See note.)
External power supply
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient operating
temperature
Ambient humidity
Ambient operating
environment
Ambient storage temperature
Power holding time
CP1L
CPU Units and Expansion Units
pulse outputs
40 I/O built-in
and CS1 series PLC
(maximum up to 160 I/O points)
controllers
• A thermistor (with low-temperature current suppression characteristics) is used in the inrush current control circuitry for the AC power supply. The thermistor
• A capacitor charge-type delay circuit is used in the inrush current control circuitry for the DC power supply. The capacitor will not be charged if a hot start is
will not be sufficiently cooled if the ambient temperature is high or if a hot start is performed when the power supply has been OFF for only a short time. In
those cases the inrush current values may be higher (as much as two times higher) than those shown above. Always allow for this when selecting fuses and
breakers for external circuits.
performed when the power supply has been OFF for only a short time, so in those cases the inrush current values may be higher (as much as two times
higher) than those shown above.
Model CP1L-@@@-A
Type AC power supply models
100 to 240 VAC 50/60 Hz
85 to 264 VAC
50 VA max. (CP1L-M40/M30DR-A) (See next page.)
30 VA max. (CP1L-L20/L14DR-A)
100 to 120 VAC inputs:
20 A max. (for cold start at room temperature)
8 ms max.
200 to 240 VAC inputs:
40 A max. (for cold start at room temperature), 8 ms max.
300 mA at 24 VDC (CP1L-M30/M40)
200 mA at 24 VDC (CP1L-L14/L20)
20 MΩ min. (at 500 VDC) between the external AC terminals and
GR terminals
2,300 VAC at 50/60 Hz for 1 min between the external AC and
GR terminals, leakage current: 5 mA max.
Conforms to IEC 61000-4-4. 2 kV (power supply line)
Conforms to JIS C0040. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s
80 minutes each. Sweep time: 8 minutes x 10 sweeps = total time of 80 minutes)
Conforms to JIS C0041. 147 m/s
0 to 55° C
10% to 90% (with no condensation)
No corrosive gas
-20 to 75° C (Excluding battery.)
10 ms min.
2
three times each in X, Y, and Z directions
DC power supply models
CP1L-@@@-D
24 VDC
20.4 to 26.4 VDC
20 W max. (CP1L-M40/M30@@-D) (See next page.)
13 W max. (CP1L-L20/L14@@-D)
30 A max. (for cold start at room temperature)
20 ms max.
None
No insulation between primary and secondary for DC power
supply
No insulation between primary and secondary for DC power
supply
2 ms min.
2
in X, Y, and Z directions for
1

Related parts for CP1LSTARTERKITAC