G4IDC5-SWNC OPTO 22, G4IDC5-SWNC Datasheet

no-image

G4IDC5-SWNC

Manufacturer Part Number
G4IDC5-SWNC
Description
I/O Module
Manufacturer
OPTO 22
Datasheet

Specifications of G4IDC5-SWNC

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Signal Input Type
Voltage
No. Of Analog Inputs
1
No. Of Digital Outputs
1
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
G4 Digital DC Input Modules
Description
Opto 22’s G4 DC input modules are used to detect on/off DC voltage
levels. Each module provides up to 4000 volts (transient) of optical
isolation between field inputs and the logic output of the circuit.
All DC input modules except the G4IDC5K and G4IDC5D are
designed with filtering on the input and a hysteresis amplifier,
providing high noise rejection and transient-free, “clean” switching.
The G4IDC5K is a fast-switching module used to detect signals
produced by photoelectric switches and TTL devices. The low-cost
G4IDC5D is used for data acquisition.
The G4IDC5MA is a special module featuring a manual-on/manual-
off/automatic switch, ideal for diagnostic testing of control
applications.
The G4IDC5-SW and G4IDC5-SWNC modules supply power to an
external dry contact switch and sense switch closure (SW) or
opening (SWNC).
Typical applications for DC input modules include sensing the
presence or absence of voltage and sensing contact closure from
sources such as proximity switches, limit switches, selector
switches, push buttons, photoelectric switches, and TTL-
compatible devices.
Features
© 2006 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
4000 volts transient optical isolation
Built-in LED status indicator
Small footprint design, reducing mounting space by
approximately 50 percent
Built-in filtering for transient suppression and noise
rejection
Operating temperature: -30 °C to 70 °C
UL recognized, CSA certified, CE approved
Passes NEMA Showering Arc Test (ICS 2-230)
Meets IEEE Surge Withstand Specification (IEEE-472)
SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com
Part Numbers
G4IDC5
G4IDC5B
G4IDC5D
G4IDC5G
G4IDC5K
G4IDC5MA
G4IDC5-SW
G4IDC5-SWNC
G4IDC15
G4IDC24
Opto 22 G4 digital input modules include the
G4IDC5B high-speed module and the G4IDC5MA module
with manual-on/manual-off/automatic switch for
diagnostic testing.
Part
G4 DC Input 10–32 VDC, 5 VDC Logic
G4 DC Input 4–16 VDC, 5 VDC Logic
High Speed
G4 DC Input 2.5–28 VDC, 5 VDC Logic
G4 DC Input 35–60 VDC, 5 VDC Logic
G4 DC Input 2.5–16 VDC, 5 VDC Logic
Very High Speed
G4 DC Input 10–32 VDC, 5 VDC Logic
With Manual/Auto Switch
G4 Switch Status Input, Self-powered,
Normally Open
G4 Switch Status Input, Self-powered,
Normally Closed
G4 DC Input 10–32 VDC, 15 VDC Logic
G4 DC Input 10–32 VDC, 24 VDC Logic
Description
PAGE
1

Related parts for G4IDC5-SWNC

G4IDC5-SWNC Summary of contents

Page 1

... The G4IDC5MA is a special module featuring a manual-on/manual- off/automatic switch, ideal for diagnostic testing of control applications. The G4IDC5-SW and G4IDC5-SWNC modules supply power to an external dry contact switch and sense switch closure (SW) or opening (SWNC). Typical applications for DC input modules include sensing the ...

Page 2

... G4IDC5-SW and G4IDC5-SWNC modules See page 4 for specifications and other information for the G4IDC5- SW and G4IDC5-SWNC self-powered modules. Schematic drawings for these modules appear on page 5. Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 2 © ...

Page 3

... SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2006 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. Units G4IDC5K G4IDC5MA VDC 2.5-16 10-32 VAC — ...

Page 4

... CAUTION: G4IDC5-SW and G4IDC5-SWNC inputs are not intended to be used with contacts that are connected to any external user- supplied voltage or currents. ...

Page 5

... SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2006 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...

Page 6

... SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2007 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...

Related keywords