32H8/CC/VH/LRR/X EUROTHERM CONTROLS, 32H8/CC/VH/LRR/X Datasheet - Page 6

Process/Temperature Controller

32H8/CC/VH/LRR/X

Manufacturer Part Number
32H8/CC/VH/LRR/X
Description
Process/Temperature Controller
Manufacturer
EUROTHERM CONTROLS
Datasheet

Specifications of 32H8/CC/VH/LRR/X

No. Of Analog Inputs
2
No. Of Analog Outputs
3
No. Of Digital Inputs
3
No. Of Digital Outputs
4
Controller Output Type 1
Voltage/SSR
Output Type
Logic, Relay
Control Operation
Auto/Manual, Ramp/Soak, Stand By, Valve Positioning
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Example ordering code (Quick Start)
This code will provide a controller configured as 0-1200 °C, Type K, Heat Output,
4-20mA PV retrans, High Alarm, 50A CT measurement, SP select via Dig In A,
Lower display showing working setpoint
Eurotherm:
AUSTRALIA Sydney
T (+61 2) 9838 0099
E info.au@eurotherm.com
AUSTRIA Vienna
T (+43 1) 7987601
E info.at@eurotherm.com
BELGIUM & LUXEMBOURG
T (+32) 85 274080
E info.be@eurotherm.com
BRAZIL Campinas-SP
T (+5519) 3707 5333
E info.br@eurotherm.com
CHINA
T (+86 21) 61451188
E info.cn@eurotherm.com
© Copyright Eurotherm Limited 2008
Invensys, Eurotherm, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon, Eyris, EPower and Wonderware are trademarks of Invensys plc, its subsidiaries and affiliates.
All other brands may be trademarks of their respective owners.
All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be stored in a retrieval system
other than for the purpose to act as an aid in operating the equipment to which the document relates, without the prior written permission of Eurotherm limited.
Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore be changed without notice.
The information in this document is given in good faith, but is intended for guidance only.
Eurotherm Limited will accept no responsibility for any losses arising from errors in this document.
Part No. HA028600 Issue 7
Optional quick start code (Optional)
Thermocouple
RTD
Linear
B
J
K
L
N
R
S
T
C
P
M
2
4
X
K - 6 - H - E - 5 - 5 - P - X - X - T
1
1
Input Type
Type B
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Custom/Type C
Pt100
0-80mV
0-20mA
4-20mA
Unconfigured
2
3
International sales and service
Beijing Office
T (+86 10) 63108914
E info.cn@eurotherm.com
Guangzhou Office
T (+86 20) 38106506
E info.cn@eurotherm.com
DENMARK Copenhagen
T (+45 70) 234670
E info.dk@eurotherm.com
FINLAND Abo
T (+358) 22506030
E info.fi@eurotherm.com
FRANCE Lyon
T (+33 478) 664500
E info.fr@eurotherm.com
4
Temperature
H
C
Centigrade
0
1
2
3
4
5
6
7
8
9
Fahrenheit
G
H
J
K
L
M
N
P
R
T
X
2
Setpoint Limits
5
Heat (PID)
Cool (PID)
0 to 100 deg C
0 to 200 deg C
0 to 400 deg C
0 to 600 deg C
0 to 800 deg C
0 to 1000 deg C
0 to 1200 deg C
0 to 1400 deg C
0 to 1600 deg C
0 to 1800 deg C
32 to 212 deg F
32 to 392 deg F
32 to 752 deg F
32 to 1112 deg F
32 to 1472 deg F
32 to 1832 deg F
32 to 2192 deg F
32 to 2552 deg F
32 to 2912 deg F
32 to 3272 deg F
Unconfigured
6
GERMANY Limburg
T (+49 6431) 2980
E info.de@eurotherm.com
HONG KONG
T (+85 2) 28733826
E info.hk@eurotherm.com
INDIA Chennai
T (+91 44) 24961129
E info.in@eurotherm.com
IRELAND Dublin
T (+353 1) 4691800
E info.ie@eurotherm.com
ITALY Como
T (+39 031) 975111
E info.it@eurotherm.com
3200 Specification Sheet
3208/h8/
7
04 only
3208/h8/
8
04 only
XX
Relay, Triac or Logic outputs
Control
H
C
J
K
Alarm output
Energised in alarm
0
1
2
3
4
Alarm output
De-energised in alarm
5
6
7
8
9
DC outputs
Control
H
C
J
K
Retransmission
D
E
F
N
Y
Z
Logic input
W
M
R
L
P
T
U
V
A
B
G
I
Q
3
4
Not fitted
Heat (PID)
Cool (PID)
Heat (On/off)
Cool (On/off)
High alarm
Low alarm
Deviation high
Deviation low
Deviation band
High alarm
Low alarm
Deviation high
Deviation low
Deviation band
4-20mA heating
4-20mA cooling
0-20mA heating
0-20mA cooling
4-20mA setpoint
4-20mA Process value
4-20mA output
0-20mA setpoint
0-20mA Process value
0-20mA output
Alarm acknowledge
Manual select
Timer/Prog Run
Keylock
Setpoint 2 select
Timer/prog reset
Remote SP select
Recipe 2/1 select
Remote up button
Remote down button
Time/prog run/reset
Timer/prog hold
Standby select
5
9
OP1, OP2, AA Relay, OP3
KOREA Seoul
T (+82 31) 2738507
E info.kr@eurotherm.com
NETHERLANDS Alphen a/d Rijn
T (+31 172) 411752
E info.nl@eurotherm.com
NORWAY Oslo
T (+47 67) 592170
E info.no@eurotherm.com
POLAND Katowice
T (+48 32) 2185100
E info.pl@eurotherm.com
SPAIN Madrid
T (+34 91) 6616001
E info.es@eurotherm.com
10
T
S
P
R
E
1
A
D
C
M
N
X
W
M
R
L
P
T
U
V
A
B
G
I
Q
10
XX
1
2
5
6
6
7
CT Input
8
Lower Display
Working setpoint
Target setpoint
Output demand
Time to run
Elapsed time
Alarm setpoint
Load amps
Dwell/ramp - time/target
WSP with output meter
WSP with ammeter
None
Not fitted
10 Amps
25 Amps
50 Amps
100 Amps
Dig in A, Dig in B, OP1
Unconfigured
Alarm acknowledge
Manual select
Timer/Prog Run
Keylock
Setpoint 2 select
Timer/prog reset
Remote SP select
Recipe 2/1 select
Remote up button
Remote down button
Time/prog run/reset
Timer/prog hold
Standby select
SWEDEN Malmo
T (+46 40) 384500
E info.se@eurotherm.com
SWITZERLAND Wollerau
T (+41 44) 7871040
E info.ch@eurotherm.com
UNITED KINGDOM Worthing
T (+44 1903) 268500
E info.uk@eurotherm.com
www.eurotherm.co.uk
U.S.A. Leesburg VA
Eurotherm Inc.
T (+1 703) 443 0000
E info.us@eurotherm.com
www.eurotherm.com
in England 03.08
recycled paper
Printed on
ED56