UM-35ACI5 TEXMATE, UM-35ACI5 Datasheet - Page 3

no-image

UM-35ACI5

Manufacturer Part Number
UM-35ACI5
Description
TEXMATE DIGITAL PANEL METER UM-35ACI5 I/P 0-5AAC DISPLAY 0-50.0AAC 115V POWER,CHILD:UM-35AC15
Manufacturer
TEXMATE
Datasheet

Specifications of UM-35ACI5

Rohs Compliant
NA
Operating Temperature Range
-10°C To +50°C
Meter Function
AC Ammeter
September 10, 2003 UM-35ACI Data Sheet (UM03)
Six Screw Terminals included Free with each UM Series meter
select between 120V AC and 240V AC power, the optional low voltage
switching power supply or the 24V AC power supply by connecting the
screw terminals as shown in the diagrams below.
A standard 30 pin edge connector (two rows of 15 pins on
0.156" centers) may also be used to connect the UM-Series.
Order part no. CN-L15. For different power supply voltage con-
nection details, see pin connections below.
Decimal Point Selection
TB-Kit Screw Connectors
Optional PCB Edge Connector
Selecting Power Supply Voltages
PCB BOARD : COMPONENT SIDE
Screw Terminals
PCB BOARD : COMPONENT SIDE
PCB BOARD : COMPONENT SIDE
A
1.XXX
1X.XX
1XX.X
1XXX.
A
Decimal
With TB-KIT
Header
A
Select
A
C
1
A
C
1
B
A
C
1
B
AC2 & 3
B
A
C
2
Joins
A
C
2
A
C
2
C
N/C
C
C
A
C
3
A
C
3
A
C
3
D
Rear View of PCB Edge Connector
D
2 TB-KITs
included
D
A
C
4
1 2
A
A
C
4
or For Optional 24V AC (P.N.:V0-24V)
A
C
4
E
For Isolated 9-36V DC/12-24V AC, 50/60 Hz
Remove faceplate by inserting a screwdriver
blade in the slot at the bottom center of the face-
plate. Press blade in to release catch and gently
pry face plate outward from the bottom. (see also
Case Dimension drawing)
Decimal selection is made on the front of the dis-
play board by moving the jumper clip to the
desired position on the header.
E
E
B C D E
For 100 to 120V AC, 50/60 Hz
Top & bottom gold
fingers are joined on PCB
3
For 200 to 240V AC, 50/60 Hz
Top & bottom gold
fingers are joined on PCB
Top & bottom gold
fingers are joined on PCB
4
5
Switching Power Supply
6
F
11 12 13 14
11 12 13 14
M
M
11 12 13 14
M
H
7
N
N
N
8
J
P R
A TB-KIT consists of 3 insulated
Quick Connects and 3 of Texmate’s
patented individual screw terminal
blocks which attach directly to PCB
inputs. These provide a Quick
Connect tab and screw clamp
termination. When using the TB-KIT
screw terminal blocks, it is possible to
P R
P R
9 10 11 12 13 14 15
K
L M N
PCB Edge Connector
With Optional
10 11 12 13 14 15
10 11 12 13 14 15
10 11 12 13 14 15
L
L
L
P R
Join these pins
Join these pins
M
M
M
N
N
N
S
P R S
P R S
P R S
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
They provide the greatest convenience and ease of use
Texmate’s exclusive optional Push-On Connectors combine an edge
card connector and a 10 position screw terminal block. Push-On
Connectors are ordered preconfigured for each specific power supply
voltage and each optional power supply available for the UM-Series.
CN-PUSH/UM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100/120V AC
CN-PUSH/UM01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200/240V AC
CN-PUSH/UM02 . . . . . . . . . . . . . . . . . . .Switch Selectable 120/240V AC
CN-PUSH/UM03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24V AC
CN-PUSH/UM04 . . . . . . . . . . . . . . . . . . . . . . . . . . .9-36V DC/12-24V AC
CN-PUSH/UM05 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V DC
To replace DPMs in existing panels where matching pinouts are
required, Texmate can provide custom pinout Change-over
Connectors, either with PCB gold finger terminations, (shown below)
or customized versions of Push-On Screw Terminals. (shown above)
Change-over Connector
shown is for Analogic models
AN25M02,AN25M03,
AN25M04 and AN25M05.
• Small Run or One-Off custom face plates incur an installation
charge, and are generally printed on a special plastic film, which is
then laminated to custom faceplate blanks as required.
• Large Run (250 pieces min): custom face plates are production
silk screened, issued a part number, and held in stock for free
installation as required by customer orders.
• OEMs may also order Custom Meter Labels, Box Labels, Custom
Data Sheets and Instruction Manuals.
Millivolts AC
Milliamps AC
Volts AC
Amps AC
Custom Face Plates
Push-On Screw Terminals
Pinout Change-Over Connectors
Face Plate Descriptors
kg/cm
Kilowatts
kWH
Connector can be
securely attached
to case with screws
k
½
CosØ
2
kVAR
Kilovolts AC
Volts DC
Amps DC
Watts
Milliamps DC
Millivolts DC
M/min
Power Factor
%
Hz
pH
DC
m /hr
RPM
3
psi
µ
A
˚C
˚F
½
To customize the face plate, each
UM-meter is supplied with a white
printed clear adhesive label con-
taining various popular descriptors.
Choose the descriptor, peel off the
adhesive backing and align the
descriptor in the lower right corner
of the standard face plate.
Texmate Produces Thousands of
Custom OEM Face Plates
Have Texmate Design and produce a
Custom Face Plate for your next project!
• Custom face plates have a non-
recurring artwork charge. A serial
number is then assigned to each
artwork to facilitate reordering.
Pinouts are marked
Part Number
CN-UM/ANLGC
on Connector
Page 3

Related parts for UM-35ACI5