E5CN-HR2MD-500 Omron, E5CN-HR2MD-500 Datasheet

no-image

E5CN-HR2MD-500

Manufacturer Part Number
E5CN-HR2MD-500
Description
CONTROLLER TEMP RELAY
Manufacturer
Omron
Datasheet

Specifications of E5CN-HR2MD-500

Thermocouple Type
B, E, J, K, L, N, R, S, T, W, PLII
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Output Voltage Max
250VAC
Output Voltage Min
5V
Svhc
No SVHC (15-Dec-2010)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A New High-performance Controller: High Resolution, High Speed, and
High Input Accuracy.
With Logic Operations and preventive
maintenance functions.
• High-resolution display with 5 digits/0.01°C display in a compact
• High-speed sampling cycle of 60 ms.
• High Accuracy
• Universal inputs on all models (thermocouple, PT, analog) to handle
• A PV/SV-status display function can be set to alternate
• Flexible contact outputs with logic operations (AND, OR, and delays)
• Preventive maintenance for relays
Main I/O Functions
Indication Accuracy
• Thermocouple/Pt input: ±0.1% of PV
• Analog input: ±0.1% FS
Universal Sensor Inputs
• Universal thermocouple/Pt/analog
Advanced Digital Temperature Controller
E5CN-H
Controller (48 x 48 mm).
Thermocouple/Pt input: ±0.1% of PV
Analog input: ±0.1% FS
various sensors with one Controller.
displaying the PV or SV and the status of the Temperature
Controller (auto/manual, RUN/STOP and alarms).
set from the Support Software (CX-Thermo Ver. 4.0)
using a Control Output ON/OFF Counter.
Sampling Period and control update
• 60 ms
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157)
E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159)
(current/voltage) inputs.
Event Inputs
• None
• Two
(48 x 48 mm)
E5CN-H
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output
Control Output 2
• None
• Voltage output
(for driving SSR)
Advanced Digital Temperature Controller
2-line Display: PV and SV
5-digit, 11 segment display
with high resolution of 0.01°C
Auxiliary Outputs
• Two
• Auto/manual switching
• Temperature Controller status display
• Simple program function
• Logic operations
• Control output ON/OFF count alarm
• PV change rate alarm
• Models optional with RS-485
or RS-232C communications
Refer to Safety Precautions on page 18.
48 × 48 mm
E5CN-H
E5CN-H
1

Related parts for E5CN-HR2MD-500

E5CN-HR2MD-500 Summary of contents

Page 1

... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157) E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159) ...

Page 2

... Universal input 2 control outputs Option Units E53-CN@@ Applicable Controller CN: E5CN-H 2. Function 1 Blank: None Q: Control output 2 (voltage output for driving SSR) 3. Function 2 Blank: None H: Heater burnout/SSR failure/Heater overcurrent detection (CT1) HH: Heater burnout/SSR failure/Heater overcurrent detection (For 3-phase heater applications, 2x CT) ...

Page 3

... DIN 48 × 48 × 78 Black (W × H × VAC/VDC Note: Add power supply voltage to model to complete ordering code (ie. E5CN-HR2M-500 AC100-240 or E5CN-HR2MD-500 AC/DC24). Option Units One of the following Option Units can be mounted to provide the E5CN with additional functions. Event inputs Event inputs Event inputs ...

Page 4

... Operating voltage range 85% to 110% of rated supply voltage 100 to 240 VAC: 8.5 VA (max.) (E5CN-HR2 at 100 VAC: 3.0 VA) Power consumption 24 VAC/VDC: 5.5 VA (24 VAC)/3.5 W (24 VDC) (max.) (E5CN-HR2D at 24 VAC: 2.7 VA) Any of the following can be selected (i.e., fully universal input). Thermocouple Sensor input ...

Page 5

... PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) Advanced Digital Temperature Controller 2300.0 1800.0 1700.01700.0 1300.0 1300.0 Usable in the following ranges by scaling: −19999 to 32400, −1999.9 to 3240.0, −199.99 to 324.00, or −19.999 to 32.400 400.0 400.0 100.0 0.0 0.0 0.0 0.0 −200.0−199.9−200 E5CN-H Analog input ...

Page 6

... X ON • Case 3: Always OFF OFF 0 ✽5. Set value: 5, Upper- and lower-limit with standby sequence X ON Always OFF when the upper-limit and lower-limit hysteresis OFF 0 overlaps OFF OFF 0 E5CN-H Case 2 Case 3 (Always ON > < ⏐H⏐ > ⏐L⏐ Case 3 (Always OFF) Case ...

Page 7

... Memory protection Non-volatile memory (number of writes: 1,000,000 times) Setup Tool CX-Thermo version 4.0 or higher Provided on the bottom of the E5CN-H. Use this port to connect a computer to the E5CN-H. Setup Tool port An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5CN-H. ✽4 Approved UL 61010-1, CSA C22 ...

Page 8

... Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 100 E5CN-H 250 VAC, 30 VDC 3 (resistive load) cosφ Switching current (A) E5CN-H 1,000 VAC for 1 min 50 Hz, 98 m/s 2 E54-CT1: Approx. 11.5 g, E54-CT3: Approx Armatures (2) Plugs ( ...

Page 9

... E53-CNH01N2 E53-CNQ01N2 Communications Communications (RS-232) (RS-232) and CT and Control Output 2 RS-232C RS-232C Control output 2 CT1 12 VDC E53-CNHH03N2 E53-CNQHN2 Communications Control Output 2 (RS-485) and CT2 and CT B (+) 11 Control output 2 RS-485 12 VDC (−) DO NOT 13 USE CT2 14 CT1 CT1 15 E5CN ...

Page 10

... Mounting Adapter Terminal Cover (Accessory) (E53-COV17) (Accessory) Note: The terminal block cannot be removed. LED indicator 250 (SD) USB connector (type A plug) E5CN-H No. 1 display No. 2 display Up Key Panel Cutout Mounted Separately Group Mounted (48 × number of units − 2.5) Group mounting does not 60 min. ...

Page 11

... Maximum continuous heater current: 120 A (50/60 Hz) (Maximum continuous heater current for an OMRON Temperature Controller is 50 A.) Number of windings: 400±2 Winding resistance: 8±0.8 Ω 100 ∞ kΩ 500 Ω 100 mV 100 Ω 50 Ω Ω 100 μ 100 100 1,000 A Thru-current (Io) A (r.m.s.) E5CN-H Distor- tion factor 10 ...

Page 12

... Adapter Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@. Mounted to E5CN-H 12 Advanced Digital Temperature Controller 4.7 76 69.6 to 77.6 72 × 72 Panel ( mm) 72 × × 48 2.2 4.7 77.3 (to back of E5CN-H) E5CN-H Fixture (Accessory) 67 × ...

Page 13

... Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). ✽ These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays. ...

Page 14

... Advanced Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Protect Level PID Setting Level Display PID Selection d.pid PID1 1 d.pid PID2 2 d ...

Page 15

... Monitor lcr2 Alarm Value Leakage Current 2 Upper Limit Monitor 0 prst Alarm Value Program Start Lower Limit rset sktr Soak Time Remain MV Monitor (Heating Monitor (Cooling Press the O and M Keys for at least 3 s. Press the O and M Keys for at least 1 s. E5CN-H 15 ...

Page 16

... Set the ON/OFF M output cycle. Control Period (Cooling) c- orev Direct/Reverse Operation or alt1 Alarm 1 Type alh1 Alarm 1 Hysteresis E5CN-H Initial Setting Level alt2 Alarm 2 Type 2 M Alarm 2 c alh2 Hysteresis alt3 Alarm 3 Type 2 M alh3 Alarm 3 c Hysteresis 0.2 M For input type of ...

Page 17

... Period 0.25 M Control Output 1 ra1m ON/OFF Count 0 Monitor M Control Output 2 ra2m ON/OFF Count 0 Monitor M Control Output 1 ra1 ON/OFF Count 0 Alarm Set Value M Control Output 2 ra2 ON/OFF Count 0 Alarm Set Value M ON/OFF Counter rac Reset 0 M cmov Move to Calibration Level 0 M E5CN-H 17 ...

Page 18

... A class 2 power supply is one tested and certified having the current and voltage of the secondary output restricted to specific levels. ✽3. The tightening torque for E5CN-U is 0.5 N·m. Precautions for Safe Use Be sure to observe the following precautions to prevent malfunction or adverse affects on the performance or functionality of the product. ...

Page 19

... IP@0 are not waterproof. Front panel: IP66 Rear case: IP20, Terminal section: IP00 (E5CN-U: Front panel: IP50, rear case: IP20, terminals: IP00) Operating Precautions 1. It takes approximately two seconds for the outputs to turn ON from after the power supply is turned ON. Due consideration must be given to this time when incorporating Temperature Controllers in a sequence circuit ...

Page 20

... The Temperature Controller can be removed from the case to perform maintenance without removing the terminal leads. This is possible for only the E5CN, E5AN, and E5EN, and not for the E5CN-U. Check the specifications of the case and Temperature Controller before removing the Temperature Controller from the case. ...

Page 21

... Advanced Digital Temperature Controller E5CN-H 21 ...

Page 22

... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...

Related keywords