E5CN-HV2MD-500 Omron, E5CN-HV2MD-500 Datasheet - Page 15

no-image

E5CN-HV2MD-500

Manufacturer Part Number
E5CN-HV2MD-500
Description
CONTROLLER TEMP VOLT
Manufacturer
Omron
Datasheet

Specifications of E5CN-HV2MD-500

Thermocouple Type
B, E, J, K, L, N, R, S, T, W, PLII
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Output Voltage Max
10VDC
Output Voltage Min
0VDC
Svhc
No SVHC (15-Dec-2010)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
c
c
c
l.a d j
ir da
lcr1
lcr2
insh
cm wt
insl
M
ct1
hb1
oc1
hs1
ct2
hb2
oc2
hs2
ins
50.0
50.0
50.0
0.00
50.0
0.00
0.00
off
off
off
at
0.0
M
M
M
M
M
0.0
M
0.0
M
M
0.0
M
M
M
0.0
M
M
0.0
M
M
M
Adjustment Level
Display
Displayed only
once when
entering
adjustment level.
AT Execute/Cancel
Communications
Writing
Infrared Communications Use
Heater Current 1
Value Monitor
Heater Burnout
Detection 1
Heater Overcurrent
Detection 1
Leakage Current 1
Monitor
Upper Limit
Temperature
Input Shift Value
Heater Current 2
Value Monitor
HS Alarm 1
Temperature Input Shift
Lower Limit
Temperature
Input Shift Value
Heater Burnout
Detection 2
Heater Overcurrent
Detection 2
Leakage Current 2
Monitor
HS Alarm 2
2-point shift
1-point shift
Adjustment Level
Set either
of these
param-
eters.
c
Press the O Key less than 1 s.
c- db
of -r
wt -b
mv -s
mv -e
ol -h
oc -h
sq rp
c- sc
ch ys
so ak
sp rt
ol -l
23 3. 0
105. 0
hy s
or l
40 . 0
1. 00
50 . 0
-5 . 0
off
M
M
M
M
M
M
M
M
M
off
M
M
M
M
M
M
db
M
M
M
8. 0
0. 0
0.0
0. 0
1. 0
0. 0
M
2. 0
0. 8
0. 0
1. 0
p
d
i
1
Cooling Coefficient
Dead Band
Proportional Band
Integral Time
Manual Reset Value
Clear the offset during
stabilization of P or PD
control.
Hysteresis (Heating)
Hysteresis (Cooling)
Open/Close Hysteresis
Derivative Time
Soak Time
Wait Band
MV at PV Error
SP Ramp Set Value
Extraction of Square
Root
Low-cut Point
MV at Stop
MV Upper Limit
MV Lower Limit
Position Proportional
Dead Band
MV Change Rate Limit
Hysteresis settings
Heating/cooling
PID settings
Advanced Digital Temperature Controller
Starting in manual mode.
Press
the O
Key for
at least
3 s.
PV/MV
c
Manual Control Level
25 .0
10 0. 0
c
c
lcr1
sp-m
lcr2
sktr
ba nk
prst
25 . 0
25 . 0
ct1
a- m
ct2
PID
Control
only
rset
M
M
M
M
M
0.0
M
M
M
M
M
M
0. 0
0.0
0.0
0.0
0.0
0
0
Process Value
Added when Additional
PV display is ON.
Process Value/
Set Point
Auto/Manual Switch
PID control only.
Added when
auto/manual select
addition is ON.
Soak Time Remain
Bank No.
Set Point During
SP Ramp
Heater Current 1 Value
Monitor
Heater Current 2 Value
Monitor
Leakage Current 1
Monitor
Leakage Current 2
Monitor
Program Start
Press the O
Key for at least
1 s.
Operation Level
Power ON
c
c
c
c
c
c
c
Starting in
automatic
mode.
al -1
al 1h
al -2
al 2h
al -3
al 3h
al 1l
al 2l
al 3l
r- s
c- o
run
M
M
M
M
M
M
M
M
M
M
M
M
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
o
RUN/STOP
Alarm Value
Upper Limit 3
MV Monitor (Heating)
Alarm Value 1
Alarm Value
Upper Limit 1
Alarm Value
Lower Limit 1
Alarm Value 2
Alarm Value
Upper Limit 2
Alarm Value 3
Alarm Value
Lower Limit 3
MV Monitor (Cooling)
Alarm Value
Lower Limit 2
E5CN-H
Press the O
and M Keys for
at least 3 s.
Press the O
and M Keys for
at least 1 s.
15