G2LM20 230VAC TELE, G2LM20 230VAC Datasheet

LEVEL MONITORING, 230VAC

G2LM20 230VAC

Manufacturer Part Number
G2LM20 230VAC
Description
LEVEL MONITORING, 230VAC
Manufacturer
TELE
Datasheet

Specifications of G2LM20 230VAC

Accessory Type
Level Monitoring Relay
Voltage Rating
230VAC
Length
90mm
External Width
90mm
External Depth
103mm
Svhc
No SVHC (18-Jun-2010)
No. Of Analogue
RoHS Compliant
For Use With
Level Monitoring And Control
Monitoring relays - GAMMA series
Multifunction
Secure isolation of the measuring circuit
2 change-over contacts
Width 22.5mm
Industrial design
Technical data
1. Functions
Level monitoring of conductive liquid, timing for tripping delay and turn-off
delay separately adjustable and the following functions (selectable by
means of rotary switch)
2. Time ranges
Tripping delay (Delay ON):
Turn-off delay (Delay OFF):
3. Indicators
Green LED ON:
Yellow LED ON/OFF:
4. Mechanical design
Self-extinguishing plastic housing, IP rating IP40
Mounted on DIN-Rail TS 35 according to EN 60715
Mounting position: any
Shockproof terminal connection according to VBG 4 (PZ1 required),
IP rating IP20
Tightening torque: max. 1Nm
Terminal capacity:
5. Input circuit
Supply voltage:
Tolerance:
Rated frequency:
Rated consumption:
Duration of operation:
Reset time:
Residual ripple for DC:
Drop-out voltage:
Overvoltage category:
Rated surge voltage:
6. Output circuit
2 potential free change-over contacts
Rated voltage:
Switching capacity:
If the distance between the devices is less than 5mm!
Switching capacity:
If the distance between the devices is greater than 5mm!
Pump up
Pump down
1 x 0.5 to 2.5mm² with/without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
24V AC
110V AC
230V AC
24V AC
110V AC
230V AC
24V AC
110V AC
230V AC
Level monitoring of conductive liquids
pump up or minimum monitoring
pump down or maximum monitoring
Adjustment range
0.5s
0.5s
indication of supply voltage
indication of relay output
terminals A1-A2 (G2LM20 24VAC)
terminals A1-A2 (G2LM20 110VAC)
terminals A1-A2 (G2LM20 230VAC)
-15% to +10% (G2LM20 24VAC)
-15% to +10% (G2LM20 110VAC)
-15% to +15% (G2LM20 230VAC)
48 to 63Hz
2VA (1.5W) (G2LM20 24VAC)
2VA (1.5W) (G2LM20 110VAC)
2VA (1.5W) (G2LM20 230VAC)
100%
500ms
-
>30% of the supply voltage
III (in accordance with IEC 60664-1)
4kV
250V AC
750VA (3A / 250V)
1250VA (5A / 250V)
10s
10s
www.tele-online.com
Fusing:
Mechanical life:
Electrical life:
Switching frequency:
Overvoltage category:
Rated surge voltage:
7. Measuring circuit
Input:
Sensitivity:
Sensor voltage:
Sensor current:
Wiring distance (capacity of cable 100nF/km):
Overvoltage category:
Rated surge voltage:
8. Accuracy
Base accuracy:
Adjustment accuracy:
Repetition accuracy:
Voltage influence:
Temperature influence:
9. Ambient conditions
Ambient temperature:
Storage temperature:
Transport temperature:
Relative humidity:
Pollution degree:
Vibration resistance:
Shock resistance:
5A fast acting
20 x 10
2 x 10
max. 60/min at 100VA resistive load
max. 6/min at 1000VA resistive load
(in accordance with IEC 60947-5-1)
III (in accordance with IEC 60664-1)
4kV
conductive probes (type SK1, SK2, SK3)
terminals E1-E2-E3
0.25 to 100kΩ (4mS to 10µS)
12V AC
max. 7mA
max. 1000m (set value <50%)
max. 100m (set value 100%)
III (in accordance with IEC 60664-1)
6kV
-
-
-
-
-
-25 to +55°C (in accordance with IEC 60068-1)
-25 to +40°C (in accordance with UL 508)
-25 to +70°C
-25 to +70°C
15% to 85%
(in accordance with IEC 60721-3-3 class 3K3)
3 (in accordance with IEC 60664-1)
10 to 55Hz 0.35mm
(in accordance with IEC 60068-2-6)
15g 11ms
(in accordance with IEC 60068-2-27)
5
6
Operations at 1000VA resistive load
Operations
G2LM20

Related parts for G2LM20 230VAC

G2LM20 230VAC Summary of contents

Page 1

... A1-A2 (G2LM20 110VAC) 230V AC terminals A1-A2 (G2LM20 230VAC) Tolerance: 24V AC -15% to +10% (G2LM20 24VAC) 110V AC -15% to +10% (G2LM20 110VAC) 230V AC -15% to +15% (G2LM20 230VAC) Rated frequency 63Hz Rated consumption: 24V AC 2VA (1.5W) (G2LM20 24VAC) 110V AC 2VA (1.5W) (G2LM20 110VAC) 230V AC 2VA (1 ...

Page 2

... Set the existent time delay to desired value to fade out a short term moisten the probes by waves in the liquid. - Set the function selector switch to desired position. (either pump up or pump down) www.tele-online.com G2LM20 ...

Page 3

... Connections RELEASE 2009/07 Subject to alterations and errors Dimensions Sonde max. Sonde min. Massesonde www.tele-online.com G2LM20 ...

Related keywords