LR04815-001 PYRO CONTROLE, LR04815-001 Datasheet - Page 6

REGULATOR, DIGITAL, STATOP 4815

LR04815-001

Manufacturer Part Number
LR04815-001
Description
REGULATOR, DIGITAL, STATOP 4815
Manufacturer
PYRO CONTROLE
Datasheet

Specifications of LR04815-001

Thermocouple Type
J, K, T, E, B, R, S, N, L
Operating Temperature Max
50°C
Operating Temperature Min
-10°C
Output Voltage Max
240VAC
Accuracy
± 2°C
External Depth
48mm
External Length /
RoHS Compliant
10
STATOP Analogue controllers
Analogue controllers with ON-OFF or Proportional (P) action.
Available in non-display and measurement display versions.
T o o r d e r
Predefined
0-1200 °C
Pt 100 Ω
Pt 100 Ω
Pt 100 Ω
Pt 100 Ω
Pt 100 Ω
0-300 °C
0-400 °C
0-600 °C
0-800 °C
0-100 °C
0-120 °C
0-200 °C
0-250 °C
0-300 °C
Type J
Type J
Type K
Type K
Type K
scale
Temperature input: J, K thermocouple or Pt 100 Ω resistance
Control direction: forward (cold) or reverse (hot)
Control algorithm: ON-OFF or P
Control output: reverse relay
115 / 230 V
115 / 230 V
200…260 V
115 / 230 V
115 / 230 V
200…260 V
115 / 230 V
200…260 V
115 / 230 V
115 / 230 V
200…260 V
115 / 230 V
115 / 230 V
Alimentation
24…230 V
24…230 V
90…260 V
24…230 V
90…260 V
24…230 V
24…230 V
90…260 V
90…260 V
90…260 V
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
LR04841-100
LR04841-101
LR04841-102
LR04841-103
STATOP 4841
STATOP Series
Operating temperature
Front panel protection
Storage temperature
Hysteresis in on-off
Dielectric rigidity
Shock resistance
Modulation pace
Control indicator
Panel cut-out
Useful depth
Vibrations
Accuracy
Humidity
Isolation
Displays
Outputs
Format
Weight
STATOP 9601
LR09601-100
LR09601-101
LR09601-103
LR09601-104
LR09601-105
LR09604-100 LR09604-101
LR09604-102 LR09604-103
LR09604-106 LR09604-107
LR09604-108 LR09604-109
LR09604-110 LR09604-101
STATOP 9604
Alarm output
two-tone “OUT” - red: active output
1/16 DIN - 48 x 48 mm
green: inactive output
STATOP 4841
STATOP 4 / MDS
P01614023
P01614025
P01614101
P01614103
45 x 45 mm
P01614001
P01614011
P01614002
P01614012
P01614022
P01614032
P01614033
P01614035
86 mm
250 g
none
STATOP 4 / MDA
P01614423
P01614425
P01614501
P01614503
Alarm output
P01614401
P01614511
P01614402
P01614512
P01614422
P01614532
P01614533
P01614535
two-tone “°C” - red: active output
reverse relay 5 A/240 V
green: inactive output
STATOP 9601
P01620201 P01620301
P01620211 P01620311
2.2 % of scale
1 % of scale
STATOP NB
IP 50
330 g
none
20 s
Alarm output
AC
53
mm
Temperature measured in °C
red "OUT": active output
STATOP 9604
2,000-point digital
Electrical connections
for logic output options
Alarm
280 g
Control
0…90 %HR (without condensation)
10…55 Hz, 10 m/s
2000 V
20 MΩ under 500 V
Power
AC
200 m/s
-10 °C.. +50 °C
-40 °C.. +60 °C
, 50/60 Hz during 1 min
STATOP 4841
STATOP 4
2
2
(20 g )
during 2 hours
Power
Output
(relay
or logic)
STATOP 4 / MDS
1/4 DIN - 96 x 96 mm
DC
92 x 92 mm
113 mm
none
Alarm
Control
reverse relay 3 A/240 V
STATOP 4 / MDA
STATOP 4/MDS
0.4 to 2 % of scale
STATOP 9601
Power
8, 12 or 16 s
1 % of scale
800 g
none
IP 40
AC
Alarm
Temperature measured in °C
1,000-point digital
Control
STATOP NB
STATOP 4/MDA
STATOP 9604
Power
Alarm
Output
(relay
or logic)
11

Related parts for LR04815-001