MTL5501-SR MTL SURGE TECHNOLOGIES, MTL5501-SR Datasheet

no-image

MTL5501-SR

Manufacturer Part Number
MTL5501-SR
Description
ISOLATED BARRIER, DIG I/P
Manufacturer
MTL SURGE TECHNOLOGIES
Datasheet

Specifications of MTL5501-SR

Input Type
Switch / Proximity Sensor
Output Type
Solid State / Fail Safe
Approval Bodies
ATEX
External Depth
123.6mm
External Length / Height
109.8mm
External Width
15.8mm
Isolation Input
Isolated
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
With the MTL5501-SR, a fail–safe switch/proximity detector
located in the hazardous area can control an isolated fail–safe
electronic output. The MTL5501–SR units provide line fault
detection alarm contacts. The MTL5501–SR is for use with approved
fail–safe sensors.
SPECIFICATION
See also common specification
Number of channels
Location of switches
Location of proximity detector
Voltage applied to sensor
Input/output characteristics
Note: Is = sensor current
Fail-safe electronic output
Line fault detection (LFD)
LED indicators
Power requirements, Vs
Power dissipation within unit
Safety description
Note: switch-type sensors must be fitted with resistors as shown
Input value in
sensor circuits
2.9mA < Is < 3.9mA
Is < 1.9mA & Is > 5.1mA
Is < 50µA
Rs < 100
MTL5501-SR FAILSAFE
SWITCH/PROXIMITY
DETECTOR INTERFACE
with LFD
One
Zone 0, IIC, T6 hazardous area
Div. 1, Group A hazardous location
Zone 0, IIC, T4–6, hazardous location
Div 1, Group A, hazardous location
8.6V dc max from 1kΩ
Output on:
Output off:
Load:
Maximum on-state current: 25mA (at 750Ω)
Short-circuit current: 30mA
LFD relay output: contacts open when line fault detected
Switch characteristics: 0.3A 110V ac/dc; 1A 35V dc; 30W/33VA
Yellow: one provided for output status, ON when fail-safe
output is energised
Green: one provided for power indication
Red: one provided for LFD, flashing when line fault is detected
@ Supply voltage
@ Supply voltage
Uo = ±9.7V, Io = 30mA, Po = 0.07W, Ci = 0nF, Li = 0mH
Um = 253V
Ω
35V dc
20V dc
24V dc
20V dc
24V dc
35V dc
EUROPE (EMEA)
AMERICAS
ASIA PACIFIC
E-mail: enquiry@mtl-inst.com
24V nominal
0V dc, max < 5V dc
750Ω to 10kΩ
Fail–safe
750Ω load
750Ω load
1232mW
1392mW
1507mW
output
100mA
90mA
65mA
OFF
OFF
OFF
ON
Tel: +44 (0)1582 723633
Tel: +1 281 571 8065
Tel: +65 6 487 7887
Web site: www.mtl-inst.com
Operation
Shorted line
Broken line
Normal
Normal
1200mW
1335mW
typ. load
typ. load
1160mW
70mA
60mA
45mA
Fax: +44 (0)1582 422283
Fax: +1 281 571 8069
Fax: +65 6 487 7997
contacts
CLOSED
CLOSED
OPEN
OPEN
LFD
The given data is only intended as a product description and should not be re-
garded as a legal warranty of properties or guarantee. In the interest of further
technical developments, we reserve the right to make design changes.
Hazardous area
Terminal
10
13
14
11
1
2
7
8
W
W
Function
Input –ve
Input +ve
Output –ve
Output +ve
LFD
LFD
Supply –ve
Supply +ve
Safe area
EPS5501SR–1
Jan 2009

Related parts for MTL5501-SR

MTL5501-SR Summary of contents

Page 1

... MTL5501-SR FAILSAFE SWITCH/PROXIMITY DETECTOR INTERFACE with LFD With the MTL5501-SR, a fail–safe switch/proximity detector located in the hazardous area can control an isolated fail–safe electronic output. The MTL5501–SR units provide line fault detection alarm contacts. The MTL5501–SR is for use with approved fail– ...