XCS-A502 TELEMECANIQUE, XCS-A502 Datasheet - Page 12

SAFETY SWITCH, 2NO/1NC

XCS-A502

Manufacturer Part Number
XCS-A502
Description
SAFETY SWITCH, 2NO/1NC
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of XCS-A502

Contact Voltage Ac Max
250V
Contact Voltage Dc Max
24V
Contact Current Ac Max
6A
Contact Current Dc Max
540mA
Switch Terminals
Screw
Approval Bodies
EN1088, EN60204, EN60947-5-1
Conduit Thread Size
M20 X
Setting-up
Function diagrams
XCS-i5iii
Schemes
Wiring to category 1 (EN 954-1)
Example with 3-pole N/C + N/O + N/O contact and protection
fuse to prevent shunting of the N/C contact, either by cable
damage or by unauthorised tampering.
(1) Signalling contact
Wiring to category 4 (EN 954-1). Wiring method used in conjunction with PREVENTA safety module.
(The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy)
Method for machines with quick rundown time (low inertia)
Locking or interlocking mechanism uses the principles of redundancy
and autocheck.The safety modules ensure these functions.
Locking by actuator and operation in positive
mode associated with a safety module.
See page 1/9.
References :
pages 2/18 to 2/21
Dimensions :
pages 2/23 and 2/24
XPS-FB
22,5
21
23
25
O
I
31
Note : These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance.
F1
X
21-22
13-14
33-34
X
(1)
Components for safety applications
Guard switches
Metal, turret head, types XCS-A, XCS-C and XCS-E
Setting-up, schemes
XCS-i7iii
M
21,5
22
25
23
31
21-22
31-32
13-14
XCS-i8iii
Wiring to category 3 (EN 954-1)
Example with 3-pole N/C + N/C + N/O contact without monitoring.
(The guard switch should be used in conjunction with a safety limit switch to give
mechanical/electrical redundancy)
(1) Signalling contact
Method for machines with long rundown time (high inertia)
Interlocking mechanism with actuator captive
in the guard and zero speed detection.
See page 1/9.
XPS-VN
23
25
31
F1
O
I
11-12
21-22
31-32
X
XPS-FB
X
(1)
Contact operation
contact closed
contact open
unstable
M
Te
2/25
2