CUB5TB00 Red Lion Controls, CUB5TB00 Datasheet
CUB5TB00
Specifications of CUB5TB00
Related parts for CUB5TB00
CUB5TB00 Summary of contents
Page 1
... The CUB5T has an LCD display with 0.46" (11.7 mm) high digits. The LCD is available in two versions, reflective (CUB5TR00) and backlight (CUB5TB00). The backlight version is user selectable for red or green backlighting with variable display intensity. ...
Page 2
... Wire Gage: 30-14 AWG copper wire Torque: 5 inch-lbs (0.565 N-m) max. 9. ENVIRONMENTAL CONDITIONS: Operating Temperature Range for CUB5TR00: -35 to 75°C Operating Temperature Range for CUB5TB00 depends on display color DESCRIPTION Preset Timer and Cycle Counter with Reflective Display Preset Timer and Cycle Counter with Backlight Display ...
Page 3
O P PTIONAL LUG ADDING OPTION CARDS The CUB5T meters can be fitted with optional relay card and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below. The plug-in cards, that are ...
Page 4
I NSTALLING The Plug-in cards are separately purchased option cards that perform specific functions. The cards plug into the main circuit board of the meter after the rear cover is removed WARNING: Disconnect all power to the meter before ...
Page 5
POWER WIRING DC Power +9 to +28 VDC: +VDC Power Common: -VDC - + PWR COMMON 4.3 INPUT WIRING CAUTION: Power input common is NOT isolated from user input common. In order to preserve the safety of the meter ...
Page 6
R EVIEWING THE KEY DISPLAY MODE OPERATION SEL Select display (timer or cycle counter) RST Reset value(s) per Front Panel Reset setting OPERATING MODE DISPLAY DESIGNATORS t “ ” the left of the display is the timer ...
Page 7
MODULE 1-INPUt SEL RANGE INPUt OP FILtEr t-dir Timer Timer Input Timer Input Range Operation Filter Direction TIMER RANGE RANGE 18 TIMER RANGE SELECTIONS 5555555 = SEC; = MIN; RANGE RANGE MAXIMUM ...
Page 8
TIMER RESET AT POWER-UP RSt P- YES YES The Timer can be programmed to Reset at each meter power-up. USER INPUT FUNCTION USErsINP NO DISPLAY MODE DESCRIPTION NO No Function User Input disabled. See ...
Page 9
MODULE 3-dSPLAY SEL SEL Enb RSt Enb Front Panel Front Panel Display Reset Enable Select FRONT PANEL DISPLAY SELECT ENABLE (SEL) SELsEnb yES NO yES yES The selection allows the button to toggle between ...
Page 10
MODULE 4-SEtPt SEL SPt ASN SPt ACt SPt ON Setpoint Setpoint On Setpoint Assignment Output Action The Setpoint Output Parameters are only active when the optional relay module is installed in the meter. Some parameters will ...
Page 11
MODULE 5-SEriAL SEL bAUd dAtA Baud Rate Data Bit Module 5 is the programming module for the Serial Communications Parameters. These parameters are used to match the serial settings of the CUB5T with those of the ...
Page 12
Sending Serial Commands and Data When sending commands to the meter, a string containing at least one command character must be constructed. A command string consists of a command character, a value identifier, numerical data (if writing data to the ...
Page 13
Command Response Time The meter can only receive data or transmit data at any one time (half-duplex operation). During RS232 transmissions, the meter ignores commands while transmitting data, but instead uses RXD as a busy signal. When sending commands and ...
Page 14
CUB5T PROGRAMMING QUICK OVERVIEW 15 ...