F35-3-73-0 Simpson, F35-3-73-0 Datasheet

no-image

F35-3-73-0

Manufacturer Part Number
F35-3-73-0
Description
3-1/2, 9-32VDC, 0-10VDC
Manufacturer
Simpson
Type
Voltager
Datasheet

Specifications of F35-3-73-0

Accuracy
±0.1% %
Cut Out, Panel
3.62×1.77 "
Digit Height
0.56
Dimensions
3.75"W×1.88"H×2.94"D
Display Digit Height
0.56 "
Display Resolution
10 mV
Display Type
LED
Function
Voltage
Number Of Digits
4-1/2
Primary Type
Electronic
Range, Measurement
0 to 10 VDC
Voltage, Supply
3 to 9 VDC
• 1/8 DIN Indicator
• 3-1/2 or 4-1/2 digit bright red LED display
• Front panel pops off for easy decimal
• Only 3.12” (79mm) required behind panel
• Optional excitation output
• NEMA 4X enclosure optional
• Din Rail Adapter available
Mounting Requirements
The Falcon series 1/8 DIN indicators require a panel cutout of
1.77" (45mm) high by 3.62" (92mm) wide. To install the Falcon
into a panel cutout, remove the clips from the side of the meter.
Slide the meter through your panel cutout, then slide the mount-
ing clips back on the meter. Press evenly to ensure a proper fit.
Tighten screws.
point setting and display scaling
For more information, visit www.simpsonelectric.com
(page C1)
Dimensions
Specifications
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ACCURACY @25°C
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
Warm-up Time
Response Time
NOISE REJECTION
NMRR
CMRR
A TO D CONVERSION
Technique
Rate
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
F45 DC Process/Voltage
F35 DC Process/Voltage
F45 DC Current
F35 DC Current
F45 AC Voltage/Current
F35 AC Voltage/Current
4.04”
3.59”
3.75
1.88
7-segment, red LED
0.56" (14.2mm)
3 or 4 position user-programmable,
internally or on the terminal block
most significant digit = "1"; other digits
blank
Automatic, with "-" indication,
"+" indication implied
120 or 220VAC, ±10% 50/60Hz
9-32DCV, ±1%
F35: 3VA, F45: 2VA
±0.02% of reading ± 1 count
750 ± 2 count
±0.1% of reading ± 1 count
750 ± 2 count
±0.05% of reading ±1 count
2A ± 5 counts
±0.1% of reading ± 1 count
2A ± 5 counts (45Hz-1KHz)
±0.5% of reading ± 35 counts (45Hz-1KHz)
±1% of reading ± 5 counts (45Hz-1KHz)
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
(±0.1% of input ± 0.5 count)/°C
Less than 15 minutes
Less than 3 seconds
50dB, 50/60Hz
(w/1K unbalanced @ 60Hz) 90dB min.
Dual slope integration
3 samples per second, nominal
3.75" x 1.88" x .51"
2.94"
3.62" X 1.77"
94V-1, UL rated Noryl®
9.0oz (255.1g)
.51
2.94
5A ± 5 counts
92 mm
1.75
more >>
2.26

Related parts for F35-3-73-0

F35-3-73-0 Summary of contents

Page 1

... Automatic, with "-" indication, "+" indication implied 120 or 220VAC, ±10% 50/60Hz 9-32DCV, ±1% F35: 3VA, F45: 2VA ±0.02% of reading ± 1 count 750 ± 2 count ±0.1% of reading ± 1 count 750 ± 2 count ±0.05% of reading ±1 count 2A ± ...

Page 2

... F35 ±0.1% of reading ± 5 counts (45Hz - 1kHz) F45 ±0.5% of reading ± 35 counts (45Hz - 1kHz) F35 & & DC Process ±0.1% of reading ± 1 count 2A ± 5 counts (45Hz - 1 kHz) F45 ±0.05% of reading ± 1 count 2A ± 5 counts 5A ± 5 counts F35 ± ...

Page 3

... Ordering Information Falcon Indicators can be configured by making an entry in each section. Example: F35-1-52-0. Basic Unit Selection Description Basic Unit 3 1/2 digit LED F35 4 1/2 digit LED F45 Power Supply 1 120 ACV 220 ACV 9-32 DCV† 120 ACV* 4 Function/Range 200 DCmV 11 2 DCV ...