UEP-12/1400-D48-C Murata Power Solutions Inc, UEP-12/1400-D48-C Datasheet
UEP-12/1400-D48-C
Specifications of UEP-12/1400-D48-C
Related parts for UEP-12/1400-D48-C
UEP-12/1400-D48-C Summary of contents
Page 1
... Models are able to bring you 15-30W in the standard 2" x 1" package from which most competitors can only get 5-10W. All UEP’s deliver their full output power over ambient temperature ranges from –40° high as +70°C (model and input voltage dependent) without heat sinks or supplemental forced-air cooling. Devices derate to +100° ...
Page 2
... Maximum Output Current in mA Optional Functions UEP converters are designed such that the 12 and 15V configured for either positive logic on/off control (no suffix) or negative logic (“N” suffix). 3.3 and 5V models are available with positive logic only (no suffix). ...
Page 3
... IN Notes. = 3.7mA max. IN Operating temperature range without derating is model and input-voltage dependent. See Temperature Derating. UEP-3.3/600-D48 and UEP-5/6000-D48 do not have overvoltage shutdown. See Absolute Maximum Ratings for allowable input voltages. Input Voltage: Continuous: D12 Models D24 Models D48 Models ...
Page 4
... Filtering and Noise Reduction All UEP Series DC/DC Converters achieve their rated ripple and noise speci- fications with no external input/output capacitors. In critical applications, input/output noise may be further reduced by installing external I/O caps. ...
Page 5
... Actual measured times will vary with input source impedance, external input/output capacitance, and load. The UEP Series implements a soft start circuit that limits the duty cycle of the applied with respect to IN PWM controller at power up, thereby limiting the Input Inrush current ...
Page 6
... This on/off cycling is referred to as "hiccup" mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. The UEP is capable of enduring an indefinite short circuit output condition. Thermal Shutdown These UEP converters are equipped with Thermal Shutdown Circuitry. If envi- ronmental conditions cause the internal temperature of the DC/DC converter rises above the designed operating temperature (typically 118° ...
Page 7
... Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s UEP-3.3/4500-D48 Efficiency vs. Line Voltage and Load Current 0.4 UEP-3.3/6000-D48 Efficiency vs. Line Voltage and Load Current www.murata-ps.com 36V 48V 75V IN 0.91 1.43 1.94 2.45 2.96 3.48 Load Current (Amps) ...
Page 8
... Temperature Derating Curves for UEP-5/3500 Output Models 20 17 18V-30V (D24 36V-60V (D48 12V (D12 18V-36V (D24 36V-75V (D48) IN 2.5 0 – Ambient Temperature ( Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’ 18V-27V (D24 36V-48V (D48) ...
Page 9
... UEP-5/3500-D48 Efficiency vs. Line Voltage and Load Current 36V 48V 75V 0.3 0.7 1.1 1.5 1.9 2.3 Load Current (Amps) UEP-5/6000-D48 Efficiency vs. Line Voltage and Load Current 36V 48V 75V Load Current (Amps) www.murata-ps.com Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s 2 ...
Page 10
... 75V 0.10 0.26 0.43 0.59 0.75 0.91 Load Current (Amps) www.murata-ps.com Single Output UEP Models Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s 1.06 1.24 1.40 UEP-15/1200-D48 Efficiency vs. Line Voltage and Load Current 0.10 0. 36V 48V 75V IN 0.38 0.51 ...
Page 11
... China: Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com © 2008 Murata Power Solutions, Inc. Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UEP Models.B02 Page ...