UMP-15/2.5-D24-C Murata Power Solutions Inc, UMP-15/2.5-D24-C Datasheet - Page 9

DC/DC TH 40W Q48-15V XMP

UMP-15/2.5-D24-C

Manufacturer Part Number
UMP-15/2.5-D24-C
Description
DC/DC TH 40W Q48-15V XMP
Manufacturer
Murata Power Solutions Inc
Series
UMPr
Datasheet

Specifications of UMP-15/2.5-D24-C

Product
Isolated
Output Power
38 W
Input Voltage Range
18 V to 36 V
Number Of Outputs
1
Output Voltage (channel 1)
15 V
Output Current (channel 1)
2.5 A
Isolation Voltage
1.5 KV
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without
notice.
Qualifi cation
sive characterization process and long-term reliability is confi rmed via a rigorous
qualifi cation procedure. The qual procedure includes such strenuous tests as
thermal shock and 500 hour life. Qual testing is summarized below.
Qualifi cation Test
HALT
High Temperature Storage
Thermal Shock
Temperature/Humidity
Lead Integrity
Life Test
Marking Permanency
End Point Electrical Tests
* Interim electrical test at 200 hours.
For each new product, electrical performance is verifi ed via a comprehen-
Qualifi cation Testing
Method/Comments
DATEL in-house procedure
Max. rated temp., 1,000 hours
10 cycles, –55 to +125°C
+85°C, 85% humidity, 48 hours
DATEL in-house procedure
+70°C, 500 hours*
DATEL in-house procedure
Per product specifi cation
www.murata-ps.com
© 2009 Murata Power Solutions, Inc.
05/18/09
In-Line Process Controls and Screening
A combination of statistical sampling and 100% inspection techniques keeps
our assembly line under constant control. Parameters such as solder-paste
thickness, component placement, cleanliness, etc. are statistically sampled,
charted and fi ne tuned as necessary. Visual inspections are performed by
trained operators after pick-and-place, soldering and cleaning operations.
Units are 100% electrically tested prior to potting. All devices are temperature
cycled, burned-in, hi-pot tested and fi nal-electrical tested prior to external
visual examination, packing and shipping.
Rapid Response to Problems
DATEL employs an outstanding corrective-action system to immediately ad-
dress any detected shortcomings in either products or processes. Whenever
our assembly, quality or engineering personnel spot a product/process prob-
lem, or if a product is returned with a potential defect, we immediately perform
a detailed failure analysis and, if necessary, undertake corrective actions.
Over time, this system has helped refi ne our assembly operation to yield one
of the lowest product defect rates in the industry.
USA:
Canada:
UK:
France:
Germany:
Japan:
China:
Singapore:
Mansfi eld (MA), Tel: (508) 339-3000, email: sales@murata-ps.com
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel:
25-40W, Single Output, DC/DC Converters