BMP-12/1.65-D24-C Murata Power Solutions Inc, BMP-12/1.65-D24-C Datasheet - Page 6

DC/DC Converter

BMP-12/1.65-D24-C

Manufacturer Part Number
BMP-12/1.65-D24-C
Description
DC/DC Converter
Manufacturer
Murata Power Solutions Inc
Type
Step Downr
Series
BMPr
Datasheet

Specifications of BMP-12/1.65-D24-C

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
2
Input Voltage
18V To 36V
Power Rating
35W
Output Voltage
12V
Output Current
1.65A
Output Voltage 2
-12V
Output Current 2
-1.65A
Supply Voltage
24V
Package
10Case C-11
Number Of Outputs
2
Output Power
35 W
Switching Regulator
Yes
Product
Isolated
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
+/- 12 V
Output Current (channel 1)
+/- 1.65 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
+/- 1.65 A
Isolation Voltage
1.5 KV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BMP-12/1.65-D24-C
Manufacturer:
GE Critical Power
Quantity:
101
Output Power
BMP Model, dual-output DC/DC converters incorporate a design tradeoff be-
tween total available output power and input voltage range. The total available
power is a function of both the nominal input voltage and the "width" of the
input voltage range. For a given nominal input (24V or 48V), narrower ranges
(2:1 vs. 4:1) have more available power. For a given "width" of input range
(2:1 or 4:1), higher nominal inputs (48V vs. 24V) have more available power.
Each device, as indicated by its part-number suffi x (Q12, Q48, D24 or D48)
has a total output power limitation of 25, 30, 35 or 40 Watts, respectively.
Observing these power limitations is the user's responsibility.
As indicated by its Part Number Structure, each ±5V, ±12V or ±15V BMP
device is capable of sourcing up to ±4, ±1.65 or ±1.3 Amps, respectively.
Users have the fl exibility of loading either output up to these limits; however
you must be extremely careful not to exceed the total output power rating of
any given device. If, for example, a ±5V device with a 30W power rating
(BMP-5/4-Q48) is sourcing 4A from its +5V output (representing 20W of
Soldering Guidelines
Murata Power Solutions recommends the specifi cations below when installing these converters. These specifi cations vary depending on the solder type. Exceeding these
specifi cations may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your
production environment may differ; therefore please thoroughly review these guidelines with your process engineers.
For Sn/Ag/Cu based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
40
35
30
25
20
15
10
5
0
–40
Wave Solder Operations for through-hole mounted products (THMT)
0
Figure 5a. Temperature Derating Without Heat Sink
20
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
25
30
35
Ambient Temperature (°C)
115° C.
270° C.
7 seconds
40
45
Temperature Derating and Electrical Performance Curves
50
For Sn/Pb based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
55
www.murata-ps.com
60
65
70
75
80
D48 Models (40 Watts)
85
105° C.
250° C.
6 seconds
90
+Output power), that device can only supply an additional 10W (2 Amps)
from its –Output.
As a consequence of this "power-allocation" fl exibility, the defi nition of "full
load," as the condition under which performance specifi cations are tested
and listed, is ambiguous. The following table lists the positive and negative
output currents that DATEL uses to defi ne each device’s "full load."
Threaded Inserts and Heatsink Installation
CAUTION: Do not use the threaded inserts to bolt the converter down to a
PC board. That will place unnecessary force on the mounting pins. Instead,
the converter is held securely by only soldering the mounting pins.
When attaching the heat sink from above the converter, use a maximum
torque of 2 inch-pounds (0.23 N-m) on the 4-40 bolts to avoid damaging the
threaded inserts. Use a tiny amount of fastener adhesive or 4-40 lockwashers
to secure the bolts.
40
35
30
25
20
15
10
5
0
–40
0
20
Figure 5b. Temperature Derating With Heat Sink
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
25
Technical enquiries email: sales@murata-ps.com, tel:
30
35
25-40W, Dual Output, DC/DC Converters
Ambient Temperature (°C)
40
45
50
55
MDC_BMP25-40W.B03 Page 6 of 6
BMP Models
60
65
70
75
+1 508 339 3000
80
85
90

Related parts for BMP-12/1.65-D24-C