GLX140-CF SOLA HEVI DUTY, GLX140-CF Datasheet - Page 18

Cover With Top Fan Kit For The GLQ140

GLX140-CF

Manufacturer Part Number
GLX140-CF
Description
Cover With Top Fan Kit For The GLQ140
Manufacturer
SOLA HEVI DUTY
Series
GLr
Type
Coversr
Datasheet

Specifications of GLX140-CF

Kit Contents
Cover With Top Fan And Mounting Screws
Product
Kits
Commercial/medical
Both
Mounting Style
Screw
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The GL Compact Series combines both medical and
non-medical approvals into one unit. These models offer
very high reliability, high effi ciency, active Power Factor
Correction, compact size and very low ground leakage
current.
Each model of GL100-M and GL200-M series complies with
the medical and ITE safety standards, enabling it to be used
for both medical or non-medical standard applications.
Specifications
158
GL Compact Series: Single Output Switchers
Power
Adjustment Range on
Main Output
Fan Output
Hold-up Time
Overload
Overvoltage Protection
Power Failure
Remote Sense
Temperature
Electromagnetic
Susceptibility
Humidity
Vibration
MTBF
Safety
Input Voltage
Frequency
Inrush Current
Efficiency
EMI/RFI
Power Factor
Safety Ground
Leakage Current
4
Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
Open collector logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted
100 W convection (80 W for GLS102-M)
Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection
10 ms @ 150 W load, 120 Vac input
contact Technical Services at (800) 377-4384 with any questions.
GL100-M Series
Short circuit protection on all outputs. Case overload protected @ 110-160% above rating
Power Supplies
>550,000 hours demonstrated at full load, and 25°C ambient conditions
Visit our website at www.solahd.com or
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Operating; non-condensing 10% to 95% RH
IEC/EN/UL 60950-1, IEC/EN/UL 60601-1
Logical Control
IEC68-2-6 to the levels of IEC721-3-2
±10% minimum on the main outputs
275 uA @ 50/60 Hz, 264 Vac input
General
Input
15-35% above nominal output
50 A max., cold start @ 25°C
90 - 264 Vac; 120 - 300 Vdc
Output
12 V @ 1 A isolated, ±5%
88% typical at full load
Features:
• Medical Approvals
• Smaller Size
• Dual Rating
• High demonstrated MTBF
• Automatic overvoltage protection
• Overload protection
• Extensive safety approvals
• Two year limited warranty
0.99 typical
47-63 Hz
16 ms @ 250 W load, 120 Vac input
125 W for convection; 200W
GL200-M Series

Related parts for GLX140-CF