GLX60 SOLA HEVI DUTY, GLX60 Datasheet - Page 2

Enclosure Kit For The GL60

GLX60

Manufacturer Part Number
GLX60
Description
Enclosure Kit For The GL60
Manufacturer
SOLA HEVI DUTY
Series
GLr
Datasheet

Specifications of GLX60

Kit Contents
Enclosure With Mounting Screws
Product
Kits
Commercial/medical
Both
Output Power Rating
60 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 300 VDC
Mounting Style
Screw
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications
Notes:
(1) Proper circuit protection required when operating with a DC input voltage. (2) Regulation and ripple may deviate from the spec at -20°C start up.
142
Power
Adjustment
Range on
Main Output
Hold-up
Time
Overload
Overvoltage
Protection
Remote Sense
Temperature
Electro-
magnetic
Susceptibility
Humidity
Vibration
MTBF
Safety
Input
Voltage
Frequency
Inrush
Current
Efficiency
EMI/RFI
Safety
Ground
Leakage
Current
4
(1)
(2)
115 Vac nominal line
cold start @ 25°C.
GL20: <15A peak
GL40: <18A peak
cold start @ 25°C
20 ms @ full load,
5 V output; 5.7 to
@ 115 Vac; <30A
@ 115 Vac; <36A
peak @ 230 Vac,
peak @ 230 Vac,
Medical: < 75 μA
outputs 10% to
nominal output
120 - 300 Vdc
6.7 Vdc. Other
85 - 264 Vac;
264 Vac input
Non-Medical:
GL20, GL40
@ 50/60 Hz,
70% typical
25% above
at full load
-5, +10%
minimum
<0.5 mA
Non-Medical: EN60950, UL UL60950 E132002, CSA CSA 22.2-234 Level 3 LR53982C, CB Certifi cate and report; CE Mark (LVD)
Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
±20% minimum for
10/20 ms 115/230
cold start @ 25°C
single output only
Class I; <0.25mA
Class II (for single
264 Vac input for
264 Vac input for
Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection protected
Medical: 275 μA
nominal output
127 - 300 Vdc
30-50% above
Non-medical:
Vac Input line
90 - 264 Vac
@ 50/60 Hz;
@ 50/60 Hz;
80% - 85%
output only)
<60A peak
@ 230 Vac,
at full load
<0.5mA
models
typical
GL50
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz
contact Technical Services at (800) 377-4384 with any questions.
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
47-63 Hz , 400± 40 Hz
on main, 5-25 V
- 6.7 Vdc. Other
+10% minimum
5 V output; 5.7
nominal output
GL60, GL110
264 Vac input
to 25% above
Non-Medical:
GL110: ±5%
on 4
outputs 10%
@ 50/60 Hz;
Power Supplies
<36 A peak
cold start @
70% typical
@ 115 Vac,
@ 230 Vac,
<18A peak
at full load
GL60: -5,
>550,000 hours demonstrated at full load and 25°C ambient conditions
<0.5 mA
Medical:
Visit our website at www.solahd.com or
< 75μA
25°C
th
Short circuit protection on all outputs. Primary overload protection
output
Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-1
FCC Class B ; CISPR 22 Class B ; EN55022 Class B
Operating; non-condensing up to 95% RH
120 - 300 Vdc
38 A max., cold
40A max., cold
85 - 264 Vac
output: 20% to
GLQ120: 65%
load. GLS120:
80% typical at
264 Vac input.
±5% minimum
above nominal
264 Vac input
3.3 V and 5 V
start @ 25°C
start @ 25°C
@ 50/60 Hz,
@ 50/60 Hz,
(2 G peak 8 Hz to 500 Hz for GL500)
typical at full
GLQ120,
GLQ120:
GLS120:
GLQ120:
GLS120:
GLS120
full load
<1 mA
0.5mA
output
35%
Refer to the selection table
General
Input
Output
264 Vac input
3.3 - 5.5V on
puts 1, 3 & 4;
@ 50/60 Hz,
output 3.3 -
25 V on 4th
main; -12 -
15V on 3rd
Tracks out-
10 to 35%
GL140
1.0 mA
output
20 ms @ full load, 115 Vac nominal line
38 A max, cold start @ 25°C
or 170 - 264 Vac
puts10% to 25%
on main, 5-25 V
±5% minimum
5 V output: 5.7
auto-selected.
220 - 300 Vdc
above nominal
264 Vac input
85 - 132 Vac
on 4
@ 50/60 Hz,
to 6.7 Vdc.
Other out-
<0.5 mA
GL150
output
75% typical at full load
th
output
264 Vac input
Non-Medical:
10% to 40%
@ 50/60 Hz,
85 - 264 Vac; 120 - 300 Vdc
< 250 μA
minimum
Medical:
2:1 wide
nominal
0.1 mA
1.0 mA
GL170
output
above
ratio
47-63 Hz
5 V output: 5.7
nominal output
264 Vac input
Other outputs
2:1 wide ratio
@ 50/60 Hz,
10% to 25%
20 A max.,
38 A max.,
to 6.7 Vdc.
cold start
cold start
<0.5 mA
@ 25°C.
@ 25°C.
GL250,
GL250:
GL350:
GL350
above
264 Vac input
Non-Medical:
85 - 264 Vac
@ 50/60 Hz,
85% typical
nominal line
50 A max.,
at full load,
cold start
<0.5 mA
Medical:
<0.3mA
20-35%
@ 25°C
nominal
GL500
output
above
±5%

Related parts for GLX60