D1U4-W-1200-12-HC1C Murata Power Solutions Inc, D1U4-W-1200-12-HC1C Datasheet - Page 4

no-image

D1U4-W-1200-12-HC1C

Manufacturer Part Number
D1U4-W-1200-12-HC1C
Description
POWER SUPPLY, SWITCH MODE, 12V
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of D1U4-W-1200-12-HC1C

Power Supply Type
Switching
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
12V
Output Current
98.3A
Power Rating
1200W
Input Voltage
90V AC To 140V AC / 180V AC To 264V AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2
Solder connector recommended for board thickness of <0.090
OUTPUT CONNECTOR AND SIGNAL SPECIFICATION
Pin Assignment
P1, P2, P7, P8
P3, P4, P5, P6
A1
A2
C5, C6, D5, D6
C3, C4, D3, D4
B1
D1
D2
B5
B6
A6
A3
A4
B2
B3
B4
D1U MATING CONNECTORS
MPS
FCI
Tyco
12V D1U mat-
ing connector
DC and Signal Connector: Tyco Part # 1-6450132-2, or FCI PowerBlade # 51732-021
www.murata-ps.com
V
P1
OUT
N/A
51742-10802400CALF
TBD
V
P2
OUT
Signal Name
V
V
Sense +
Sense -
V_
V_
I_Share
AC_OK
P_Good
PS_Kill
PS_Present
PS_On
I
I
I
I
I
2
2
2
2
2
V
OUT
RTN
C Data
C Clock
C Adr0
C Adr1
C Adr2
P3
RTN
SB
SB
Straight
Return
V
P4
RTN
Press Fit
V
P5
RTN
N/A
51762-10802400CBLF
TBD
Description
Main output voltage
Main output voltage, return
V
+ve load point
V
-ve load point
Standby voltage output
Standby voltage, return, tied internally to Output Return
Active load sharing bus
Input AC Voltage “OK” signal output (Internal pull up is
10kΩ to Vsb)
Power good signal output (Internal pull up is 10kΩ to Vsb)
Floating pin will turn off P/S (shorter pin, last-make and
fi rst-break contact for hot plugging). This signal overrides
PS-On in disabling the Main Output
Internally tied to Vsb return
Internal 1K ohm pull-up to Vsb, (accepts open collector/
drain drive), This signal to be pulled low to turn-on power
supply
I
I
Address input 0, internal pull-up to Vsb
Address input 1, internal pull-up to Vsb
Address input 2, internal pull-up to Vsb
2
2
OUT
OUT
C serial data bus
C serial clock bus
remote sense, positive node input, connected to the
remote sense, negative node input, connected to the
V
P6
RTN
Right Angle
V
P7
OUT
V
P8
OUT
SENSE +
I_SHARE
AC_OK
SPARE
D1U4-W-1200-12-Hx Series
N/A
51742-10802400AALF
TBD
x1
I
P_GOOD
SENSE -
2
SPARE
C ADR0
Technical enquiries email: toronto@murata-ps.com, tel:
x2
Straight
High Level
Low Level
0 – 8V
>2.4V (active, OK)
<0.4V
>2.4V (active, Good)
<0.4V
>2.1V (open, or Vsb)
<0.7V (active, PS:On)
0 V
>2.1V (open, or Vsb)
<0.7V (active, PS:On)
Vsb
Vsb
>2.1V, < Vsb
<0.8V
>2.1V, <Vsb
<0.8V
>2.1V, <Vsb
<0.8V
I
I
RETURN
RETURN
2
2
C ADR1
C DATA
V_
V_
x3
SB
SB
AC/DC Front End Power Supply
I
RETURN
RETURN
Solder
2
CLOCK
C ADR2
V_
V_
I
x4
2
C
SB
SB
36-0430032-0
51762-10802400ABLF
TBD
2
D1U4-1200-12-Hx.A04 Page 4 of 5
PS_KILL
SPARE
+OUT
+OUT
V_
V_
x5
mate-last pins
I Max
-4 mA / +5 mA
+4 mA
-2 mA
+4 mA
-2 mA
N/A
-1 mA
±1 mA
±1 mA
±1 mA
SB
SB
-4 mA
Right Angle
PRESENT
PS_ON
+OUT
+OUT
V_
V_
PS_
+1 (866) 740 1232
x6
SB
SB
D
C
B
A

Related parts for D1U4-W-1200-12-HC1C