S4K2U3000-C SOLA HEVI DUTY, S4K2U3000-C Datasheet
S4K2U3000-C
Specifications of S4K2U3000-C
Related parts for S4K2U3000-C
S4K2U3000-C Summary of contents
Page 1
Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (double- conversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time from external to internal power. When utility ...
Page 2
... Number 120 Vac, 50/60 Hz Models 700/630 S4K2U700-C 1000/900 S4K2U1000-C 1500/1350 S4K2U1500-C 2000/1800 S4K2U2000-C 3000/2700 S4K2U3000-C 230 Vac, 50/60 Hz International Models 1000/900 S4K2U1000-5C 2000/1800 S4K2U2000-5C 3000/2700 S4K2U3000-5C * Full/Half Load (in minutes). contact Technical Services at (800) 377-4384 with any questions. Uninterruptible Power Systems Typical Back-up Times ...
Page 3
... Up to 10,000 ft. [3,000 m] at +40°C [+104°F] without derating 50,000 ft. [15,000 m] max. Visit our website at www.solahd.com or S4K2U2000-C S4K2U3000-C 23.7 x 16.9 x 3.4 [602 x 430 x 85] 29.4 x 23.4 x 10.6 [747 x 5607 x 270] 51.1 [23.2] 71.4 [32.4] 57 ...
Page 4
... IEC62040 ISTA Procedure 1A +25°C to +30°C [+77°F to +86°F] 100% to 93% Visit our website at www.solahd.com or S4K2U2000-C S4K2U3000-C <48 dBA max ft front & sides; <48 dBA max ft rear Ed. +30°C to +35°C +35°C to +40°C [+86°F to +95°F] [+95°F to +104°F] ...
Page 5
... Up to 3,000 m [10,000 ft.] at +40°C [+104°F] without derating 15,000 m [50,000 ft.] max. Visit our website at www.solahd.com or S4K2U2000-5C S4K2U3000-5C 602 x 430 x 85 [23.7 x 16.9 x 3.3] 717 x 570 x 262 [28.2 x 22.4 x 10.3] 51.1 [23.2] 71.4 [32.4] 57.3 [26.0] 79 ...
Page 6
... IEC/EN/AS 62040 IEC62040-2 2 ISTA Procedure 1A +25°C to +30°C [+77°F to +86°F] 100% to 93% Visit our website at www.solahd.com or S4K2U3000-5C <48 dBA max ft.] front & sides; <48 dBA max ft.] rear Ed. = CISPR22 Class A Ed. nd +30°C to +35°C +35°C to +40°C [+86°F to +95°F] [+95° ...
Page 7
... Up to 10,000 ft. [3,000 m] at +40°C [+104°F] without derating 50,000 ft. [15,000 m] max. Agency UL1778, cUL Listed FCC Part 15, Class A = CISPR22 Class B IEC62040-2 2 ISTA Procedure 1A Visit our website at www.solahd.com or S4K2U96BATC S4K2U3000C (-5) 23.7 x 16.9 x 3.4 [602 x 430 x 85] 28.2 x 22.4 x 10.3 [717 x 570 x 262] 93.5 [42.4] 101.4 [46. 9.0 Ah Ed. nd ...
Page 8
S4K2U-C and S4K2U-5C Battery Back-up Times Number of Model 200 Batteries VA 1 700 1000 Internal battery 1500 2000 3000 700 126 1000 128 Internal battery + 1 1500 external battery cabinet 2000 3000 700 264 1000 252 Internal battery ...