NLP65-9912J Emerson Network Power, NLP65-9912J Datasheet - Page 3

12v 65W 3" X 5" Medical, With Harmonic Correction, RoHS Compliant

NLP65-9912J

Manufacturer Part Number
NLP65-9912J
Description
12v 65W 3" X 5" Medical, With Harmonic Correction, RoHS Compliant
Manufacturer
Emerson Network Power
Type
Open Framer
Datasheet

Specifications of NLP65-9912J

Product
Switching
Output Current (max)
5.4A
Input Voltage
85 to 264V
Output Voltage
12V
Number Of Outputs
1
Output Power (max)
65W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
127mm
Product Depth (mm)
76.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
10
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Ordering Information
Notes
1
2
3
4
5
6
7
8
9
10 Maximum continuous output power for all multiple output models must not exceed 75 Watts with 20 CFM forced air cooling at 50
11 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
12 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search
Natural convection cooling. Models NLP65-9929J, and NLP65-9908Jmust not exceed 62.5 Watts continuous output power with natural convection. Model
NLP65-9920J not to exceed 65 Watts continuous output power with natural convection.
When the input voltage is less than 90 Vac the operating temperature range is 0
Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated
with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz.
To maintain stated regulation then:
for single output units
I ≥ 0.2 A I max.
for multiple output units
0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A I(A) max.
For optimum reliability, no part of the heatsink should exceed 120
CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements.
This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
tool at http://www.PowerConversion.com to find a suitable alternative.
Voltage
Output
+12 V
–12 V
+24 V
+12 V
+12 V
+15 V
+24 V
+5 V
+5 V
+5 V
Max
2.5 A
0.5 A
2.5 A
5.4 A
4.4 A
2.7 A
7 A
7 A
2 A
7 A
(1)
Output Current
0.81 A
9.1 A
3.3 A
9.1 A
2.6 A
9.1 A
3.3 A
5.7 A
3.5 A
Peak
7 A
Fan
6.5 A
5.3 A
3.5 A
8 A
3 A
1 A
8 A
2 A
8 A
3 A
(10)
o
C, and no semiconductor case temperature should exceed 130
Ripple
150 mV
120 mV
240 mV
150 mV
120 mV
150 mV
240 mV
50 mV
50 mV
50 mV
(4)
°
C to +40
Regulation
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±2.0%
±5.0%
±2.0%
±2.0%
±2.0%
Total
°
C. The ripple and regulation specifications may not be met.
(6)
Model Number
NLP65-9908J
NLP65-9920J
NLP65-9929J
NLP65-9912J
NLP65-9915J
NLP65-9924J
(11, 12)
Embedded Power for
Business-Critical Continuity
o
o
C.
C.
Rev.02.25.11_104
NLP65 Medical
3 of 4

Related parts for NLP65-9912J