OKY-T/10-W5P-C Murata Power Solutions Inc, OKY-T/10-W5P-C Datasheet
OKY-T/10-W5P-C
Specifications of OKY-T/10-W5P-C
Related parts for OKY-T/10-W5P-C
OKY-T/10-W5P-C Summary of contents
Page 1
... For full details go to www.murata-ps.com/rohs Programmable DOSA-SMT 10/16-Amp DC/DC Converters PRODUCT OVERVIEW The OKY-T/10 and -T/16 series are SMT non- isolated Point-of-Load (POL) DC/DC power convert- ers for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifi cations (www.dosapower.com). Applications include pow- ering CPU’ ...
Page 2
... Performance Specifi cations and Ordering Guide ORDERING GUIDE I OUT V (Amps Power OUT Model Number (Volts) max) (Watts) OKY-T/10-W5P-C 0.7525-3.63 10 33.0 OKY-T/10-W5N-C 0.7525-3.63 10 33.0 OKY2-T/10-W5P-C 0.7525-3.63 10 33.0 OKY2-T/10-W5N-C 0.7525-3.63 10 33.0 OKY-T/16-W5P-C 0.7525-3.63 16 52.8 OKY-T/16-W5N-C 0.7525-3.63 16 52.8 OKY2-T/16-W5P-C 0.7525-3.63 16 52.8 OKY2-T/16-W5N-C 0.7525-3. ...
Page 3
... The Remote On/Off can be provided with either positive (P suffi negative (N suffi x) polarity. ** Vtrack Seq applies only to OKY2 models. No connection for OKY models. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page Function P66 On/Off Control * +Vin Vtrack Seq** Gnd (Common) +Vout Trim ...
Page 4
... Tpcboard=+25 °C, full output load, natural air convection. (4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground benign, +25ºC., full output load, natural convection. www.murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page -T/10 & T/16-W5 Series Dynamic Characteristics 100μSec max. to within ±2% of fi nal value ...
Page 5
... C/sec High trace = normal upper limit Low trace - normal lower limit www.murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page -T/10 & T/16-W5 Series Less than 1 ºC. per second seconds 260 ºC. Less than 3 ºC. per second Less than 1 ºC. per second seconds 235 ºC. ...
Page 6
... In order to minimize circuit errors and standardize tests between units, scope measurements should be made using BNC connectors or the probe ground should not exceed one half- inch and soldered directly to the test circuit. www.murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page -T/10 & T/16-W5 Series CURRENT PROBE +INPUT ...
Page 7
... Negative polarity devices are on (enabled) when the On/Off pin is left open or brought to within a low voltage (see Specifi cations) with respect to –Vin. The device is off (disabled) when the On/Off is pulled high (see Specifi cations) with respect to –Vin. www.murata-ps.com OKY -T/10 & T/16-W5 Series email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page ...
Page 8
... ESD diodes. This feature is variously called “mono- tonic” because the voltage does not decay or produce a negative transient once the input power is applied and startup begins. Sequence/Tracking operation is not available during pre-bias startup. www.murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page -T/10 & T/16-W5 Series email: sales@murata-ps.com ...
Page 9
... OKY -T/10 & T/16-W5 Series (Vin=5V, Vout=3.3V, airfl ow direction is transverse) Natural convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (ºC) Trace 2=Enable In, Trace 1=Vout Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page ...
Page 10
... OKY -T/10 & T/16-W5 Series (Vin=5V, Vout=2.5V, airfl ow direction is transverse) Natural convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (ºC) Trace 2=Enable In, Trace 1=Vout Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page ...
Page 11
... OKY -T/10 & T/16-W5 Series (Vin=5V, Vout=1.8V, airfl ow direction is transverse) Natural convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (ºC) Trace 2=Enable In, Trace 1=Vout Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page ...
Page 12
... Load Curre nt (Amps) On/Off Enable Startup Delay (Vin=5V, Vout=1.5V, Iout=16A, Cload=0) Step Load Transient Response (Vin=5V, Vout=1.5V, Cload=0, Iout=16A to 8A) www.murata-ps.com OKY -T/10 & T/16-W5 Series Trace 2=Enable In, Trace 1=Vout Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page ...
Page 13
... OKY -T/10 & T/16-W5 Series (Vin=5V, Vout=1.2V, airfl ow direction is transverse) Natural convection 100 LFM 200 LFM 300 LFM, 400 LFM Ambient Temperature (ºC) Trace 2=Enable In, Trace 1=Vout Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page ...
Page 14
... Vout=1.8V, airfl ow direction is transverse) Natural convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (ºC) (Vin=3.3V, Vout=0.75V, airfl ow direction is transverse) Natural convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (ºC) email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page ...
Page 15
... Programmable DOSA-SMT 10/16-Amp DC/DC Converters On/Off Enable Startup Delay (Vin=5V, Vout=0.75V, Iout=16A, Cload=0) Trace 2=Enable In, Trace 1=Vout Step Load Transient Response (Vin=5V, Vout=0.75V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. Model Number OKY-T/10-W5P-C OKY-T/10-W5N-C OKY2-T/10-W5P-C OKY2-T/10-W5N-C OKY-T/16-W5P-C OKY-T/16-W5N-C ...
Page 16
... T/16-W5 Series ROUND HOLES 1.75 .069 40.40 1.591 OBLONG HOLES THIRD ANGLE PROJECTION 44.0 101.6 1.73 4.00 REF (CORE) REEL INFORMATION (250 UNITS PER REEL) © 2010 Murata Power Solutions, Inc. email: sales@murata-ps.com 22 Mar 2010 MDC_OKY_T10T16.W5.A03 Page 9.14 .360 ...