PDUBHV20 Tripp Lite, PDUBHV20 Datasheet - Page 2

PDU Dual Source Hot Swap 200-240V 16A C13 C19 8 Outlet 2U RM

PDUBHV20

Manufacturer Part Number
PDUBHV20
Description
PDU Dual Source Hot Swap 200-240V 16A C13 C19 8 Outlet 2U RM
Manufacturer
Tripp Lite
Datasheet

Specifications of PDUBHV20

Power Rating
3680 W
Output Voltage Rating
200 V to 240 V
Number Of Outlets
6
Tower / Rackmount
Rackmount
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Features
Specifications
OVERVIEW
Model Type
PDU Type
OUTPUT
Output Watt Capacity
(watts)
Frequency compatibility
Output nominal voltage
Outlet quantity / type
INPUT
PDU Input Voltage
Recommended
Electrical Service
Maximum Input Amps
(A)
Input connection type
Plug Type
PDU Plug Type
Input cord length (ft.)
Voltage compatibility
(VAC)
Phase
LEDS ALARMS & SWITCHES
Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected
server or networking loads
PDUBHV20 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated 2200 to 3000VA with a C20 input cable
2U horizontal rackmount form factor compatible with 2 or 4 post racks
Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see
manual)
Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C19-C20 interconnect cables included - user
supplied alternate cabling supported)
6 C13 and 2 C19 outlets support critical networking loads in both Utility and UPS operating modes
One additional C19 pass-through outlet supports UPS input power cord
Dual input power cables support PDU connection to separate Utility and UPS power sources
Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the
UPS system is removed and replaced with a fresh one
Once the new UPS is up and running with all connection s restored, set the switch back to the UPS setting to once again provide
fully-conditioned UPS power to connected equipment
Hot-Swap
Hot-Swap
3680
50 / 60 Hz
200-240V
6 C13 and 2 C19 outlets support critical connected loads; 1 designated pass-through C19 outlet supports C20
input plug from UPS
200; 208; 230; 240
200V, 208V, 220V, 230V, 240V
16
UTILITY & UPS inputs are available from separately labelled C20 inlets, compatible with included C19-C20
interconnect cables or with compatible user-supplied cabling
Two IEC320-C20 inlets
IEC-320 C20
6
200-240
Single-Phase

Related parts for PDUBHV20