PH100S280-5 TDK Corporation, PH100S280-5 Datasheet - Page 55

no-image

PH100S280-5

Manufacturer Part Number
PH100S280-5
Description
Power Supply, Power Rating 100 Watt, Output Current Rating 20.00 Ampere
Manufacturer
TDK Corporation
Datasheet

Specifications of PH100S280-5

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PH100S280-5
Manufacturer:
LAMBDA
Quantity:
37
Part Number:
PH100S280-5
Manufacturer:
LAMBDA
Quantity:
492
Part Number:
PH100S280-5
Quantity:
60
(3)Component Selection
・All specifications are subject to change without notice.
PH
PC
It is control terminal for parallel operation. It is connected
in all of PH modules in parallel operation. Shorten a wire
between PC terminals as much as possible. Unavoidably
the wire is long, then use twisted pair wire or shielded wire
to avoid noise affects.
When PC terminals in parallel operation are mutually con-
nected, voltage of all PC terminal is the average of PC
terminals at open circuit. +Input side of internal Op-Amp
A1(2/2) of parallel operation in proportion to the output
current in the module is supplied. At -input, voltage in pro-
portion to average of total output currents of all the mod-
ule is supplied. This Op-Amp makes output voltage of PH
modeles with less output current risen by TRM terminal
and activates output current in PH module balance.
TRM
TRM terminal in each PH module is connected. Con-
necting TRM terminal, control circuit of parallel operation
adjusts the output voltage of the module and balance the
output current.
-S
It is GND level of control circuit of parallel operation. Inter-
nal circuit activates based on -S. It shall be connected to
-S terminal of PH module. -S connection between modules
is to be connected one point of earth to avoid electrical
potential difference of each -S terminal of PH module by
voltage drop due to output current.
Refer to following items to select components in control
circuit of parallel operation
Op-Amp (A1)
Use an Op-Amp which has singular power operation and
its input common mode voltage range from 0V. More-
over, it shall be low input off set voltage. For an example,
uPC842C(NEC) is one of available Op-Amp.
Transistor・FET (Q1-Q3)
FET (Q1) uses as analog switch. Use N channel small sig-
nal MOS-FET for general purpose (rated more than 25V,
50mA.)
Use NPN small signal type for transistor (Q2-Q4) (rated
more than 25V, 50mA.)
Capacitor (C1-C6)
For choosing capacitor(s), refer to values expressed in Fig-
ure3-2 and values for each component shown in Table3-2.
Use film capacitor or ceramic capacitor which has good
temperature characteristics.
The tolerance shall be less than ±5% .
Resistor (R1-R23, VR1)
For choosing capacitor(s), refer to values expressed in Fig-
ure3-2 and values for each component shown in Table3-2.
The tolerance shall be less than ±5% .
300S, 600S
Values for each Component
Values of Capacitor C1, Resistor R1-R4, R18, R20, R23,
and Variable Resistor VR1 depend on model. Refer to Ta-
ble3-1 for components in PH300S280-*and Table3-2 for
components in PH600S280-*.
PH300S280, PH30048
PH600S280
Others
Values of capacitors and resistors are recommended val-
ues to operate power modules which have components
used in basic connection shown in Application Note. These
values may sometimes differ from the optimum values be-
cause of components at input and output side and wiring
environment. Confirm the performance of the circuit using
actual module when each value is determined.
4 Cautions for Wiring
Wiring from Input of A1 (1/2) to CS and -V terminals shall
be minimum length. Be aware of noise affects for A1 (1/2)
which makes small voltage amplify tens to hundreds times.
Also, load wire to united point of each load wire from output
of the power supply shall be minimum length too. Long wir-
ing can cause mis-operation of control circuit of parallel op-
eration. Unavoidably the wire is long, then attach an approx.
1mF capacitor between -V terminal and -S terminal.
If -S wiring is close by and parallel to load wire, use shield-
ed wire or twisted pair wire to connect -S to -V and also -S
itself. Without any measure, electrode of -S may be unstable
by influences of load wire and mis-operation may be oc-
curred.
C1
R1
R2
R3
R4
R18
R20
R23
VR1
C1
R1
R2
R3
R4
R18
R20
R23
VR1
Table3-1 PH300S280, PH300S48
Table 3-2 PH600S280
1000p 1000p 1000p
1000p 1000p 1000p
150k
180k
180k
200k
3.3V
3.3V
1.2k
1.2k
9.1k
5.6k
1.2k
1.2k
9.1k
5.6k
18k
50k
18k
50k
150k
180k
180k
200k
1.2k
1.2k
1.2k
1.2k
30k
12k
18k
50k
30k
12k
18k
50k
Values for components in Control
Circuit of Parallel Operation
Values for components in Control
Circuit of Parallel Operation
5V
5V
300k
360k
100k
220k
270k
100k
1.2k
1.2k
1.2k
1.2k
12V
12V
30k
15k
11k
30k
15k
11k
430k
470k
100k
360k
390k
100k
330p
330p
2.7k
2.7k
4.7k
2.7k
2.7k
4.7k
15V
15V
30k
15k
30k
15k
750k
820k
200k
510k
560k
200k
330p 1000p
330p 1000p 1000p
5.1k
5.1k
2.4k
5.1k
5.1k
2.4k
24V
24V
30k
15k
30k
15k
unit : C[F], R[Ω]
100k
100k
470k
510k
200k
240k
7.5k
7.5k
1.8k
7.5k
7.5k
1.8k
28V
28V
30k
15k
30k
15k
750k
820k
360k
200k
390k
430k
360k
100k
330p
48V
48V
10k
10k
30k
15k
10k
10k
30k
15k
B-353
PH

Related parts for PH100S280-5