ZWS100AF36 TDK Corporation, ZWS100AF36 Datasheet

36V@2.8A

ZWS100AF36

Manufacturer Part Number
ZWS100AF36
Description
36V@2.8A
Manufacturer
TDK Corporation
Series
ZWSr
Datasheets

Specifications of ZWS100AF36

Voltage - Output
36V
Number Of Outputs
1
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
36 VDC @ 2.8A
Size / Dimension
8.74" L x 2.44" W x 1.38" H (222mm x 62mm x 35mm)
Power (watts) - Rated
100.8W
Operating Temperature
-10°C ~ 70°C
Efficiency
82%
Approvals
CE, CSA, EN, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
285-1699
Notes:
(1) 25C ambient (cold start)
(2) Avoid prolonged operartion in overload
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
AC Input Voltage range
DC Input Voltage range
Inrush Current (100/200VAC) (1)
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ) @ 100VAC
Remote Sense
Operating Temperature
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated
Recommended EMI Filter
Weight (Typ)
Size (WxHxD)
Warranty
Input Transient Protected
2 Year Warranty
Peak Power capability
MODELS
(2)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm
EM
ms
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MAW12R5-22
(open frame) -10ºC~+60ºC, derate linearly to 70% load from 50ºC~60ºC
(with cover) Additional derating applies, please consult Installation Manual
120/120
ZWS10
ZWS5
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
10 - 55Hz (1 minute sweep), 19.6m/s
~140% diode clamp
>100M at 25C & 70%RH, Output to Ground 500VDC
UL60950-1, CSA60950-1, EN60950-1, CE Mark
Output to Ground 500VAC (100mA) for 1 min.
ZWS Series
Benefit
Factory Automation
Test & Measurement
Light Industrial
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Withstands harsh environments
Lower Cost of Ownership
Can drive high current start up devices
EN55022-B, FCC Class B, VCCI-B
Universal Input (85 - 265VAC)
Input transient protected
2 year warranty
High quality design
Peak Power capability
85-265VAC (47-440Hz)
Single Output, High Reliability
See Outline Drawings
110 - 330VDC
-30 to +85ºC
< 196.1 m/s
10 - 95% RH
MAW1201-22
MAW1202-22
<0.02%/ºC
Convection
140/270
15 / 30
~125%
2 years
ZWS15
ZWS30
None
17
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
Gaming, Vending, Printers
2
2
constant X, Y, Z 1 hour
~115 - 130%, manual reset
MAW1202-22
ZWS50
370
99

Related parts for ZWS100AF36