C-Series General Specifications Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors, Supplementary (Guide CCN/QVNU2, File E75596) UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel ...
Page 2
Electrical Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Notes for Table A: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and ...
Page 3
C-Series General Specifications Electrical Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller. Notes for Table B: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated ...
Page 4
Electrical Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. Notes from Table D: 1 Special catalog number required. Consult factory. Table E: Lists UL Recognized, CSA Accepted ...
Page 5
C-Series – General Specifications Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) UL489: AC,240 VAC. (See Table D), 50/60 Hz, 125 VDC Current Rating Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, ...
Page 6
Series Poles Aux/Alarm Actuator Circuit Switch 1 SERIES C 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole ...
Page 7
C-Series Handle Parallel Pole UL489A Listed – Ordering — Series Poles Aux/Alarm Actuator Circuit Switch 1 SERIES C 2 ACTUATOR 1 A Handle, one per pole S Mid-Trip Handle, one ...
Page 8
Series Poles Aux/Alarm Actuator Circuit Switch 1 SERIES C 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole ...
Page 9
C-Series Sealed Toggle UL Recognized – Ordering Scheme — Poles Series Actuator Circuit 1 SERIES C 2 ACTUATOR 1 M Sealed Toggle, one per pole 3 POLES 1 One 2 Two ...
Page 10
Series Poles Actuator Circuit 1 SERIES C 2 ACTUATOR 1 Two Color Visi-Rocker Single color C Indicate ON, vertical legend J Vertical legend D Indicate ON, horizontal legend K Horizontal ...
Page 11
C-Series Rocker UL Listed – Ordering Scheme — Series Poles Aux/Alarm Actuator Circuit Switch 1 SERIES C 2 ACTUATOR 1 Two Color Visi-Rocker Single color C Indicate ON, vertical legend ...
Page 12
C — Series Actuator Poles Circuit 1 SERIES C 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal ...
Page 13
C-Series Flat Rocker UL Listed – Ordering Scheme — Series Poles Aux/Alarm Actuator Circuit Switch 1 SERIES C 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 ...
Page 14
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one aux. switch is normally supplied, as viewed in ...
Page 15
C-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuits. 4 Available only as special catalog number. 88 www.carlingtech.com ...
Page 16
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com C-Series Handle – Form & Fit Drawings 89 ...
Page 17
C-Series Handleguard – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 90 www.carlingtech.com ...
Page 18
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Line and Load terminals must be paralleled with copper bus with a minimum cross sec- tion of .078 square inches [50.32 sq. mm.]. www.carlingtech.com ...
Page 19
C-Series Sealed Toggle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 92 www.carlingtech.com ...
Page 20
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. www.carlingtech.com C-Series Rocker – Circuit & Terminal Diagrams 93 ...
Page 21
C-Series Rocker – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate ...
Page 22
Notes: 1 For pole orientation with horizontal legend, rotate front view clockwise 90°. 2 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com C-Series Flat Rocker – Form & Fit Drawings 95 ...