Description
FUSE, THERMAL CUT OFF, 2A
Manufacturer
Panasonic
Series
EYPr
Datasheet

Specifications of EYP2MP098AFT

Fuse Current
2A
Terminal Type
Thin
Holding Temperature
65°C
Svhc
No SVHC (18-Jun-2010)
Actuating Temperature Max
98°C
Approval Bodies
CSA, VDE
Approval Category
UL Recognised
Body
RoHS Compliant
Functioning Temperature
98°C
Rohs Compliant
Yes
Body Length
4.2mm
External Depth
0.64mm
Thermal Cutoffs (TCO)/
Thermal-links
EYP
● Small and Insulation Type
● High Reliability
● Solid Structure
● Thin Type
● Halogen-free (Thin type MP and MU series)
● UL, C-UL (U.S.A.)
● CSA
● VDE
● BEAB
● CCC
Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
● RoHS compliant
● Axial lead type (N, F and E series)
● Thin type (MP and MU series)
Features
TCO is compact and insulated, featuring quick temperature response, and mountable in a small space without
insulation or protection.
TCO opens reliably when the equipment becomes abnormal, and is not resettable.
Unique formed lead provides reliable TCO connection and provides easy assembly handling. (Axial lead type only)
Thick is less than 0.8 mm (MP series), available for spot welding (MP and MU series)
The thin type fuses with a part number listed in this catalog contain no halogen other than any that may exist as
an impurity.
Approved Safety Standards
See Ratings in details.
Construction
PS
E
✽ Thin type is not to be soldered.
Sealant (Epoxy resin)
Series:
Series:
Series:
Series:
Series:
Series:
Insulating
case(Ceramic)
(Japan)
(Canada) : 1
(Germany) : 481106-1171-
(U.K.)
(China)
N
F
E
H
MP
MU
Special resin
: Approved by JET
: E60271
: C
: 20020102050042
(Flux)
Fusible alloy (Pb·Cd free)
Insulating film
Special formed
lead wire
(Tin plating copper)
(LR67163)
– 381 –
● Transformers, Solenoids, Ventilation fans, Electric
● Radial lead type (H series)
Recommended Applications
fans, Small electric motors, Driers, Gas home appliances,
Fluorescent lights, Electric shavers, Adaptors, Heating
devices, ICs, Batteries, etc. The TCO can also be used
for overheating protection.
Fusible alloy
(Pb·Cd free)
Insulating
case (Ceramic)
Sealant
(Epoxy resin)
Special resin (Flux)
Terminal (Ni or Ni plating)
Fusible alloy (Pb·Cd free)
Thermal Cutoffs (TCO)
Special resin
(Flux)
Lead wire
(Tin plating copper)
00
Sep. 2010

Related parts for EYP2MP098AFT

EYP2MP098AFT Summary of contents

Page 1

... Thick is less than 0.8 mm (MP series), available for spot welding (MP and MU series) ● Halogen-free (Thin type MP and MU series) The thin type fuses with a part number listed in this catalog contain no halogen other than any that may exist as an impurity. ● RoHS compliant ■ ...

Page 2

Ratings ● N series Type No. of Rated Approved Functioning Part No. ✽1 Standards Temp (°C) N082 86 EYP2BN082 EYP2BN099 N099 102 EYP2BN109 N109 114 EYP2BN110 N110 115 EYP2BN127 N127 134 EYP2BN134 N134 139 EYP2BN143 N143 145 ...

Page 3

E series Type No. of Rated Approved Functioning Part No. ✽1 Standards Temp (°C) EYP05BE101 E101 102 EYP05BE115 E115 115 EYP05BE134 E134 134 EYP05BE138 E138 139 EYP05BE145 E145 145 Note: (1) For long lead types add the ...

Page 4

... MP series Rated Functioning Functioning Temp. Part No. ✽1 Temp (°C) (°C) EYP2MP092AFT 92 88 EYP2MP098AFT 98 94 Note: (1) The information of the Approved Safety Standards is furnished as of Jun. 2010. Approved Safety Standards File No. UL:E60271 ● MU series Rated Functioning Functioning Temp. Part No. ✽1 Temp (°C) (° ...

Page 5

Dimensions in mm (not to scale) ● Axial lead type L Dimensions (mm) φD φ Series 9.0±1.0 2.5±0.2 3 max. +0.20 F Series 6.0±1.0 1.85 2.2 max. –0.15 E Series 5.0±0.5 1.5±0.1 1.8 max. (✽) For long ...

Page 6

Safety Precautions (Handling Precautions) The following are precautions for individual products. Please also refer to the common precautions shown on page 4 of this catalog. ● Design Applications 1. Use the TCO within their specifi ed temperature and electrical ratings. ...

Page 7

Bending > > Soldering, Welding, Calking 1) Lead wires are to be soldered with the standard conditions shown in Table 1. Excessive soldering heat and soldering time may cause damage to a TCO. If higher ...