ERZVF2M391 Panasonic, ERZVF2M391 Datasheet - Page 5

VARISTOR, SMD, 390V

ERZVF2M391

Manufacturer Part Number
ERZVF2M391
Description
VARISTOR, SMD, 390V
Manufacturer
Panasonic
Datasheet

Specifications of ERZVF2M391

300a
Suppressor Type
Ptc Fuse Case
SMD
Clamping Voltage
710V
Peak Energy (10/1000us)
10J
Voltage Dc
350V
Voltage Rating Vac
275V
Operating Temperature Range
-40°C To
Suppressor Type
Absorber
Rohs Compliant
Yes
Peak Surge Current @ 8/20µs
300A
Varistor Case
SMD
Clamping Voltage Vc Max
650V
Voltage Rating Vdc
320V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ERZVF2M391
Manufacturer:
PANASONIC
Quantity:
240 000
Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Standard Test
Condition
Varistor Voltage
Maximum Allowable
Voltage
Clamping Voltage
Rated Power
Maximum Energy
Maximum
Peak Current
Temperature Co ef fi cient
of Varistor Volt age
Impulse Life (I)
Impulse Life (II)
Performance Characteristics
Characteristics
Electrical measurements (initial/after tests) shall be conducted at
temperature of 5 to 35 °C, relative humidity of maximum 85 %
The voltage between two terminals with the specifi ed measuring
current CmA DC applied is called Vc or V
should be made as fast as possible to avoid heat effects.
The recommended maximum sinusoidal wave voltage (rms) or the
maximum DC voltage that can be applied continuously.
The maximum voltage between two terminals with the specifi ed
impulse current (8/20 µs).
The maximum power that can be applied within the specifi ed
ambient temperature.
Maximum energy of less than ±10 % of the varistor voltage
change when the standard impulse (2 ms) is applied one time.
Maximum current of less than ±10 % of the varistor voltage change
when impulse current (8/20 µs) is applied twice continuously with
an interval of 5 minutes.
The change of Vc shall be measured after the specifi ed impulse
is applied 10000 times continuously with an interval of 10 seconds
at room temperature.
The change of Vc shall be measured after the specifi ed impulse
is applied 100000 times continuously with an interval of 10
seconds at room temperature.
V
ERZVF M220 to ERZVF M680
ERZVF M820 to ERZVF M271
ERZVF M331 to ERZVF M471
ERZVF M220 to ERZVF M680
ERZVF M820 to ERZVF M271
ERZVF M331 to ERZVF M471
CmA
at 85 °C – V
V
CmA
Part Number
Part Number
at 25 °C
CmA
at 25 °C
Test Methods
60
1
Waveform
Waveform
8/20 µs
8/20 µs
8/20 µs
8/20 µs
8/20 µs
8/20 µs
CmA
“ZNR” Surge Absorbers, SMD Type
100(%/°C)
. The measurement
Current
Current
50 A
30 A
35 A
20 A
18 A
12 A
To meet the
specifi ed value.
0 to –0.05 %/°C
∆V
∆V
CmA
CmA
Specifi cations
/V
/V
CmA
CmA
———
< ±10 %
< ±10 %
00 Sep. 2008

Related parts for ERZVF2M391