200E2C2.75 Littelfuse Inc, 200E2C2.75 Datasheet - Page 2

BULK / FUS 2.75KV MV E-RATED 200E

200E2C2.75

Manufacturer Part Number
200E2C2.75
Description
BULK / FUS 2.75KV MV E-RATED 200E
Manufacturer
Littelfuse Inc
Datasheet

Specifications of 200E2C2.75

Current Rating
200 Amps
Voltage Rating
2.75 KVolts
Fuse Size / Group
200E
Termination Style
Clip
Fuse Type
Time Delay / Slow Blow
Product
Medium Voltage Fuse
Interrupt Rating
80 KAmps
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
E Rated Medium Voltage Fuses
Current-Limiting
“E” Rated fuses have time current characteristics designed to
provide current-limiting protection for power transformers, potential
transformers, power centers, feeder centers, and unit sub stations.
When properly applied, they can protect against high and low fault
currents.
NEMA Standards for “E” rated medium voltage fuses require that
fuses rated 100E or less open within 300 seconds (5 minutes) when
subjected to an RMS value of 200-240% of the fuse continuous current
rating; and fuses with an “E” rating larger than 100E must open within
600 seconds (10 minutes) when subjected to an RMS current of 220-
240% of the fuse’s continuous current rating. These values establish
one point on the time-current curve.
Application Note:
Since these fuses are used for the protection of general purpose
circuits which may contain transformers, motors, and other equipment
producing in-rush and/or overload currents, fuses should generally be
rated at 140% of the normal full load current, and circuits should be
analyzed to ensure that system load currents will not exceed the current
rating of the fuse.
© 2005 Littelfuse
Rated
E
Catalog Number
200E-2C-2.75
300E-2C-2.75
350E-2C-2.75
400E-2C-2.75
450E-2C-2.75
100E-1C-2.75
125E-1C-2.75
150E-1C-2.75
200E-1C-2.75
125E-2C-2.75
150E-2C-2.75
175E-2C-2.75
225E-2C-2.75
250E-2C-2.75
10E-1C-2.75
15E-1C-2.75
20E-1C-2.75
25E-1C-2.75
30E-1C-2.75
40E-1C-2.75
50E-1C-2.75
65E-1C-2.75
80E-1C-2.75
POWR-GARD
Products Catalog
Old Catalog Number
LCX 30E
LCX 40E
LCX 50E
LCX 65E
LCX 80E
LCX 300E
LCX 10E
LCX 100E
LCX 125E
LCX 150E
LCX 175E
LCX 200E
LCX 250E
LCX 400E
Size
100E
150E
200E
150E
200E
225E
250E
300E
350E
400E
450E
125E
125E
175E
10E
15E
20E
25E
30E
40E
50E
65E
80E
w w w . l i t t e l f u s e . c o m
Medium Voltage Fuses
Dim. A (inches)
Center)
Dim.A
(Clip
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
7"
Characteristics
Voltage Rating: 2,400 volts – 38,000 volts
Current Range: 10E – 600E
Options
• Hermetically sealed for use in hazardous locations
• Clip-lock (CL) and bolt-in styles available.
(add “S” suffix to part number)
Figure 14
3"DIA
D
Dim.B
Dim. B (inches)
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
10.875"
Figure 15
6.38"
DD
Rating RMS (Asym)
Max Interrupting
AA
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
Figure Number
Figure 16
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
DDD
9.75"
69