IEGH111-1-72-30.0-91-V AIRPAX, IEGH111-1-72-30.0-91-V Datasheet - Page 7

no-image

IEGH111-1-72-30.0-91-V

Manufacturer Part Number
IEGH111-1-72-30.0-91-V
Description
IEGH CIRCUIT BREAKER, ONE HANDLE PER POLE, THREE POLES, 30 AMPS
Manufacturer
AIRPAX
Datasheet

Specifications of IEGH111-1-72-30.0-91-V

No. Of Poles
3
Current Rating
30A
Interrupting Capacity
5kA
Dielectric Strength
3.75kV
Trip Time
60s
Rohs Compliant
Yes
115
Relay Trip
This permits the overload sensing coil to be placed in a
circuit which is electrically isolated from the trip
contacts. The coil may be actuated by sensors
monitoring pressure, flow, temperature, speed, etc.
Other typical applications include crowbar, interlock
and emergency /rapid shutdown circuitry. Trip may be
accomplished by voltage or current, which must be
removed after trip.
Dual Coil
By combining two electrically independent coils on a
common magnetic circuit, it is possible to provide
contact opening when either an over-current or trip
voltage is applied to the respective coils. One coil will
be a current trip coil with standard specifications. The
second, or dual coil, can be used to provide a control
function permitting contact opening from a remote
interlock or other transducer functions. Standard coils
are 6, 12, 24, 48, 120 and 240 volts. Tripping is
instantaneous and must be removed (usually self-
interrupting) after trip.
Voltage Trip
Sometimes called “dump circuits” or “panic trip
circuits,” these units make it possible to open main
power contacts with lower power inputs from one or
more sources. This configuration is becoming
increasingly more important for sensitive circuitry and
denser packaging in automation systems. Available in
series, shunt or relay configurations.
IAG/IUG/IEG/CEG/LEG Series - Configurations
[14.50]
.571
[35.05]
1.380
Optional Barriers (IEG Only)
Note: Tolerance ± .015 [.38] unless noted.
[35.05]
1.380
[35.05]
[15.75]
1.380
[5.84]
[5.84]
.620
.230
.230
Dimensions in brackets [ ] are millimeters.
[15.75]
.620
[5.84]
[38.86]
[38.86]
1.530
1.530
.230
[38.86]
1.530
2.52 MAX.
[64.00]
(See Note A)
[50.80]
2.52 MAX.
[64.00]
(See Note A)
2.000
2.52 MAX.
[64.00]
(See Note A)
http://airpax.sensata.com/
Relay
Dual Coil
Dual Coil
http://airpax.sensata.com/
DCR and Impedance based on 100% rated current applied and stabalized for
a minimum of one hour. Tolerance .05-2.5 amperes ± 20%: 2.6 -20 amperes
± 25%, 21-50 amperes ± 50%. Consult factory for special values and for coil
impedance of delays not shown.
*CEG type units are available only with 51, 52, ,53 and 59 delays LEG type units are available only with 61, 62, 63 and 69 delays
**135% minimum trip point for delays 71, 72, 73 and 79
Current Ratings
TYPICAL RESISTANCE / IMPEDANCE
PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)
Delay
71**
72**
73**
79**
51*
52*
53*
59*
61*
62*
63*
69*
(Amps)
41
42
43
49
64
65
66
0.200
1.00
2.00
5.00
10.0
20.0
30.0
50.0
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
No Trip
100%
51, 52, 53, 59
(ohms)
0.0027
0.0019
0.053
0.016
0.006
36.6
1.38
0.31
DC
.700 to 12
.440 to 10
1.8 to 100
May Trip
May Trip
May Trip
May Trip
.500 to 6.5
80 to 700
.120 Max
10 to 120
50 to 700
10 to 120
50 to 700
.120 Max
50 to 600
.120 Max
2 to 60
.7 to 12
125%
61, 62, 63, 69
AC, 50/60Hz
Impedance
(ohms)
0.0026
0.0018
0.051
0.013
0.005
34.2
1.47
0.25
.100 Max
.050 Max
.100 Max
.100 Max
.500 to 8.0
35 to 350
.300 to 3.0
1.8 to 30
40 to 400
.35 to 7.0
30 to 400
30 to 400
30 to 400
.300 to 7
1.7 to 60
.35 to 7
5 to 70
6 to 60
6 to 60
150%
41, 42, 43, 49
AC, 400Hz
(ohms)
0.004
0.100
0.027
0.008
74.2
2.85
0.64
IAG/IUG/IEG/CEG/LEG Series - Operating Characteristics
.130 to 3.0
.100 to 3.0
.150 to 1.9
12 to 120
.050 Max
.100 to 1.2
15 to 150
.050 Max
10 to 150
10 to 150
.050 Max
10 to 150
.050 Max
2.2 to 25
.13 to 3
1 to 10
2 to 20
2 to 20
1 to 20
200%
INRUSH PULSE TOLERANCE
OPERATING CHARACTERISTICS
Inrush Pulse Tolerance
The following table provides a comparison of inrush
pulse tolerance with and without the inertial delay
feature for each of the 50/60Hz delays. Pulse
tolerance is defined as a single pulse of half sine
wave peak current amplitude of 8 milliseconds
duration that will not trip the circuit breaker. The
table at left provides a guide to determine if the
inertia delay feature is required. Consult factory for
further assistance.
.031 to .500
61F, 62F, 63F, 71F, 72F, 73F
.020 Max
.022 Max
.022 Max
.020 to .40
.40 to 5.0
.15 to 2.0
.023 Max
1.5 to 20
.030 to 1
1.5 to 20
.030 to 1
1.5 to 20
1.8 to 20
.2 to 3.0
2 to 20
.03 to 1
.15 to 3
.2 to 3
61, 62, 63, 71, 72, 73
400%
64, 65, 66
Delay
.012 to 2.2
.006 to .25
.020 Max
.011 to .25
.017 Max
.015 to .3
.017 to .3
.017 Max
.012 to .3
.016 Max
.012 to 2
.22 to 10
.04 to 1
.23 to 9
.02 to 2
.4 to 10
.02 to 2
.4 to 10
.04 to 2
600%
10 times rated current (approx)
12 times rated current (approx)
25 times rated current (approx)
.018 to .55
.013 to .85
.017 to .76
.004 to .15
.008 to .79
.018 to .88
.020 Max
.017 Max
.006 to .2
.01 to .22
.008 to .5
.01 to .15
.015 to .8
.01 to .16
.017 Max
.015 Max
.004 to .1
.014 to 5
.004 to .1
800%
Pulse Tolerance
.006 to .15
.006 to .28
.011 to .50
.004 to .05
.020 Max
.004 to .08
.006 to .1
.012 to .2
.017 Max
.008 to .1
.01 to .25
.013 to .5
.017 Max
.015 Max
.008 to .1
.014 to 3
.004 to .1
.01 to .1
.01 to. 6
1000%
116

Related parts for IEGH111-1-72-30.0-91-V