PGR-7200-00-00 Littelfuse Inc, PGR-7200-00-00 Datasheet

no-image

PGR-7200-00-00

Manufacturer Part Number
PGR-7200-00-00
Description
BULK / KIT - FPR WITH TIA-232 AND CIM
Manufacturer
Littelfuse Inc
Datasheet

Specifications of PGR-7200-00-00

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
© 2010 Littelfuse
POWR-GARD
POWR-GARD
Feeder Protection (PGR 7000 Family)
PGR-7200 SeRieS
Feeder Protection Relay
NOTE: The PGR-7200 consists of the Feeder Protection Relay (pictured above)
and the PGA-OCIM Current Input Module (not pictured).
NOTE: The PGR-7200 consists of the Feeder Protection Relay and the PGA-0CIM Current Input
Module (not pictured). To order the relay only, add (-FPU) to the part number listed above.
Wiring Diagram
Ordering Information
CataloG/ SyStem NUmBeR
PGR-7200-00-00
PGR-7200-01-00
PGR-7200-02-00
PGR-7200-04-00
aCCeSSoRieS
PGC 2000 Series
PGC Family
POWR-GARD
PHASE CURRENT
TRANSFORMER
PGC 2000 SERIES
POWR-GARD
CURRENT INPUT MODULE
PGA-0CIM
13
12
Included (See Ordering Info)
POWR-GARD
MOTOR PROTECTION RELAY
PGR-7200 SERIES
(required)
RELAY 2
POWR-GARD
11
14
CIM
15
10
A
®
®
16
9
POWR-GARD
GROUND-FAULT
CURRENT TRANSFORMER
PGC FAMIL Y
TEMPERATURE
17
8
®
®
®
Protection Relay Catalog
(required)
INPUT
®
18
7
Protection Relays, Monitors & Systems
Protection Relays, Monitors & Systems
RELAY 1
19
®
6
RELAY 3
26
B
DIG IN
21
ReqUiRemeNt
Required
Required
5
CommUNiCatioNS
TIA-232
TIA-232 & RS-485
TIA-232 & DeviceNet™
TIA-232 & Ethernet
25
22
CONTROL POWER
4
23
+
ANALOG
OUTPUT
3
4-20 mA
24
2
1
I/0 MODULE
27
......
31
PaGe
38
38
25
Description
The PGR-7200 Feeder Protection Relay provides integrated
protection, metering, and data-logging functions. It is an excellent
choice for retrofitting and upgrading older relays, because of its
compact size and ability to use existing CTs. The PGR-7200 is
used to protect distribution feeders in processing, manufacturing,
petroleum, chemical, and wastewater treatment facilities.
Features & Benefits
Specifications
Protective Functions
(IEEE Device Numbers)
Input Voltage
Power-Up Time
Ride-Through Time
24-Vdc Source
AC Measurements
Frequency
Output Contacts
Approvals
Communications
Analog Output
Conformally Coated
Warranty
Mounting
(Control Unit)
(Current Input Module) DIN, Surface
Accessories
FeatUReS
IEC & IEEE Overcurrent
Protection Curves
Two Setpoint Groups
Reduced Overcurrent
Mode
Data Logging
Overload
Phase Loss/Phase
Reverse (Current)
Unbalance (Current)
Communications
A
B
PGC-2000 Series Phase Current Transformers
Required CT detects phase current or ground-
fault current (200-A primary). Other current
ratios available.
PGC Family Ground-Fault Transformers
Required zero-sequence current transformers
detect ground-fault current. Available with 5-A
and 30-A primary ratings for low-level pickup.
65–265 Vac, 30 VA; 80–275 Vdc, 25 W
800 ms at 120 vac
100 ms minimum
400 mA maximum
True RMS and DFT, Peak 32 samples/cycle and
positive and negative sequence of fundamental
50, 60 Hz
Three Form C
CSA certified to US and Canadian standards
TIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)
4–20 mA, programmable
Standard feature
10 years
Overload (49, 51)
Phase sequence (46)
Unbalance (46)
Phase loss (46)
Panel (standard)
Surface (with PGK-0SMK converter kit)
BeNeFitS
Definite and inverse time settings for system
coordination; prevents catastrophic failures
Create distinctive settings for maintenance or for
two different loads
Maintenance mode setting to reduce the risk of
Arc-Flash Hazards
On-board 100-event recorder and remote data
logging helps with system diagnostics
Prevents insulation failures and fires; extends
motor life
Detects unhealthy supply conditions
Prevents overheating due to unbalanced phases
Remotely view measured values, event records
& reset trips
Definite-Time Overcurrent (50, 51)
Inverse-Time Overcurrent (50, 51)
Ground fault (50G/N, 51G/N)
RTD/PTC temperature (49)
www.littelfuse.com/pgr-6210
www.littelfuse.com/pgr-7200