S6006DRP Littelfuse Inc, S6006DRP Datasheet - Page 12

SCR THYRISTOR, 3.8A, 600V, TO-252AA

S6006DRP

Manufacturer Part Number
S6006DRP
Description
SCR THYRISTOR, 3.8A, 600V, TO-252AA
Manufacturer
Littelfuse Inc
Type
SCRr
Datasheet

Specifications of S6006DRP

Peak Repetitive Off-state Voltage, Vdrm
600V
Gate Trigger Current Max, Igt
15mA
Current It Av
3.8A
On State Rms Current It(rms)
6A
Peak Non Rep Surge Current Itsm 50hz
83A
Repetitive Peak Off-state Volt
600V
Off-state Voltage
600V
Average On-state Current
3.8A
Hold Current
30mA
Gate Trigger Current (max)
15mA
Gate Trigger Voltage (max)
1.5V
Package Type
DPAK
Peak Repeat Off Current
10uA
Peak Surge On-state Current (max)
100A
On State Voltage(max)
1.6V
Mounting
Surface Mount
Pin Count
2 +Tab
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Breakover Current Ibo Max
100 A
Rated Repetitive Off-state Voltage Vdrm
600 V
Off-state Leakage Current @ Vdrm Idrm
0.01 mA
On-state Rms Current (it Rms)
6 A
Forward Voltage Drop
1.6 V
Gate Trigger Voltage (vgt)
1.5 V
Gate Trigger Current (igt)
15 mA
Holding Current (ih Max)
30 mA
Mounting Style
SMD/SMT
Package / Case
TO-252
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SCRs
Figure E6.26 Power Dissipation (Typical) versus RMS On-state Current
http://www.littelfuse.com
+1 972-580-7777
(25 A and 35 A)
32
28
24
20
16
12
8
4
0
0
CURRENT WAVEFORM: Half Sine Wave
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 180˚
4
RMS On-state Current [I
8
12
16
20
T(RMS)
24
] – Amps
28
32
36
E6 - 12
Figure E6.27 Power Dissipation (Typical) versus RMS On-state Current
(40 A through 70 A)
60
50
40
30
20
10
0
0
CURRENT WAVEFORM: Half Sine Wave
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 180˚
10
RMS On-state Current [I
20
30
40
T(RMS)
Thyristor Product Catalog
50
] – Amps
©2004 Littelfuse, Inc.
60
Data Sheets
70

Related parts for S6006DRP