Transmission from the ASCII Unit to a Peripheral Device
The RTS signal is activated by the OPEN command. (The DTR signal goes HIGH or LOW depending on the
peripheral device which has been opened by the command.)
When the RTS signal goes HIGH, the status of both the CTS and DSR signals is checked, and then data is
transmitted.
Transmission from a Peripheral Device to the ASCII Unit
The DTR signal goes HIGH and the RTS signal goes LOW when the OPEN command is executed. (If the
DTR signal has already gone HIGH and the RTS signal has gone LOW, the state of these signals is main-
tained.)
The RTS signal goes HIGH when the INPUT command is executed and incoming data is received. (This oper-
ation is independent of the DSR and CTS signals.)
If the RTS signal is already HIGH when the OPEN command is executed, it will remain HIGH. The RTS signal
goes LOW when the CLOSE command is executed.
DTR (output)
RTS (output)
DSR (input)
CTS (input)
Data
ON
OFF
ON
OFF
Note 1. If the DSR or CTS signal is disabled, these signals will be ignored. How-
OPEN
2. If the name of the peripheral device in the OPEN command is TERM or
3. If the name of the peripheral device in the OPEN command is LPRT or
For LPRT, SCRN
ever, if the CTS signal to port 2 needs to be disabled, either pull it HIGH
or connect it to the RTS signal. If the RTS signal is selected as the valid
signal by the OPEN command, the RTS signal will remain HIGH. The
RTS signal goes low when the CLOSE command is executed.
COMU, when the OPEN command is executed, the DTR signal will go
HIGH and the RTS signal will go LOW. The RTS signal will go HIGH when
the PRINT command is executed. If both the CTS and DSR signals are
HIGH, data will then be transferred.
SCRN, when the OPEN command is executed, both the DTR and RTS
signals will go LOW. The RTS signal will go HIGH when the PRINT com-
mand is executed. If both the CTS and DSR signals are HIGH, data will
then be transferred.
PRINT
Data transmission
For TERM, COMU
Data transmission
END
For
Port 2
Appendix B
CLOSE
For
Port 1
113
Related parts for C200HBAT09
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
50 WATTS (AC) DC/DC SINGLEI OUTPUT
Manufacturer:
POWERBOX [Powerbox]
Datasheet:
Part Number:
Description:
C200 1.8-inch Nand Flash Ssd
Manufacturer:
Micron Semiconductor Products
Datasheet:
Part Number:
Description:
C200 1.8-inch Nand Flash Ssd
Manufacturer:
Micron Semiconductor Products
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: