BTHQ21608VSS-SRE BATRON, BTHQ21608VSS-SRE Datasheet

LCD MODULE, ALPHANUMERIC, 16X2

BTHQ21608VSS-SRE

Manufacturer Part Number
BTHQ21608VSS-SRE
Description
LCD MODULE, ALPHANUMERIC, 16X2
Manufacturer
BATRON
Datasheet

Specifications of BTHQ21608VSS-SRE

No. Of Digits / Alpha
32
Character Count X Line
16 X 2
Character Size
9.22mm
Supply Voltage
5V
Display Area Width
99mm
Display Area Height
23mm
Operating Temperature
RoHS Compliant
Display Mode
Reflective
Backlighting Colour
Yellow
Rohs Compliant
Yes
Operating Temperature Range
0°C To +50°C
Feb/2002
BATRON
BTHQ 21608VSS-SRE
1/12
DOCUMENT NUMBER AND REVISION
VL-FS-BTHQ 21608VSS-01 REV.A
(BTHQ 21608VSS-SRE)
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de

Related parts for BTHQ21608VSS-SRE

BTHQ21608VSS-SRE Summary of contents

Page 1

... BATRON DOCUMENT NUMBER AND REVISION DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 VL-FS-BTHQ 21608VSS-01 REV.A (BTHQ 21608VSS-SRE) Feb/2002 BTHQ 21608VSS-SRE 1/12 www.data-modul.de ...

Page 2

... BATRON REVISION HISTORY REVISION DATE FROM TO A 2002.01.04 First Release DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 BTHQ 21608VSS-SRE CHANGED CHECKED BY BY PHILIP CHENG TOM LEE www.data-modul.de 2/12 ...

Page 3

... BATRON 1. GENERAL DESCRIPTION 2. MECHANICAL SPECIFICATIONS 3. ABSOLUTE MAXIMUM RATINGS 3.1 ELECTRICAL MAXIMUM RATINGS (Ta=25°C) 3.2 ENVIRONMENTAL CONDITION 4. ELECTRICAL SPECIFICATIONS 4.1 INTERFACE SIGNALS 4.2 TYPICAL ELECTRICAL CHARACTERISTICS 4.3 TIMING SPECIFICATIONS 4.4 TIMING DIAGRAM OF VDD AGAINST V0 DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 ...

Page 4

... BATRON 1. General Description • 16 characters ( dots lines STN Positive Yellow Reflective LCD Character Module. • Viewing Angle: 6 o’clock direction. • Driving scheme: 1/16 duty, 1/5 bias. • ‘SAMSUNG’ KS0070BP-00CC (Die form) LCD Controller & Driver or equivalent. 2. Mechanical Specifications The mechanical detail is shown in Fig. 1 and summarized in Table 1 below. ...

Page 5

... BATRON DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 BTHQ 21608VSS-SRE 5/12 www.data-modul.de ...

Page 6

... BATRON 3. Absolute Maximum Ratings 3.1 Electrical Maximum Ratings( ° ° ° ° C) Parameter Power Supply voltage (Logic) Power Supply voltage (LCD drive) Input voltage Note: The modules may be destroyed if they are used beyond the absolute maximum ratings. All voltage values are referenced to VSS = 0V. ...

Page 7

... BATRON 4. Electrical Specifications 4.1 Interface signals Pin No. Symbol 1 VSS Ground (0V). 2 VDD Power supply for logic (+5.0V Power supply for LCD driver 4 RS Register Select Input: ”High’ for Data register (for read and write) ”Low” for Instruction register (for write), ...

Page 8

... BATRON 4.2 Typical Electrical Characteristics +25 ° ° ° ° C, VDD = +5V± ± ± ± 5%, VSS = 0V. Parameter Supply voltage (Logic) Supply voltage (LCD) Input signal voltage 1 for E,DB0-DB7,R/W,RS Input signal voltage 2 for OSC1 Supply Current (Logic & LCD) Supply Current (LCD) Note (1): There is tolerance in optimum LCD driving voltage during production and it will be within the specified range ...

Page 9

... BATRON 4.3 Timing Specifications °C to +50 °C , VDD = 5V±5%, VSS=0V. Refer to Fig. 2, the bus timing diagram for write mode. Parameter E cycle time E rise time E fall time E pulse width (High, Low) R/W and RS set-up time R/W and RS hold time Data set-up time Data hold time Refer to Fig ...

Page 10

... BATRON Figure 2: The bus timing diagram for write mode . DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 BTHQ 21608VSS-SRE 10/12 www.data-modul.de ...

Page 11

... BATRON Figure 3: The bus timing diagram for read mode . DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 BTHQ 21608VSS-SRE 11/12 www.data-modul.de ...

Page 12

... BATRON 4.4 Timing Diagram of VDD against V0. Power on sequence shall meet the requirement of Figure 4, the timing diagram of VDD against V0. LOGIC SUPPLY VOLTAGE 0V OV LCD SUPPLY VOLTAGE DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 95% 50ms(typical) Figure 4: Timing diagram of VDD against V0. ...