XBO R 300 W/60C OFR OSRAM SYLVANIA, XBO R 300 W/60C OFR Datasheet

no-image

XBO R 300 W/60C OFR

Manufacturer Part Number
XBO R 300 W/60C OFR
Description
LAMP, XENON, 17V
Manufacturer
OSRAM SYLVANIA
Datasheet

Specifications of XBO R 300 W/60C OFR

Supply Voltage
17V
Power Rating
300W
Current Rating
19A
Length
80mm
Horizontal Bulb Life
1000h
Product Information Bulletin
XBO
Xenon Short Arc Lamp
FO140 R2
Lamp / order reference
(Product ordering number)
Electrical data:
Rated lamp wattage
Power Operation range
Rated lamp current (DC)
Current control range
Photometric data:
Color temperature
Color rendering index
Geometrical data:
Beam-to-axis angle α
Length l
Length p
Length r
Reflector diameter D
Diameter d
Diameter d
Electrical connection
Working distance
Technical Data
d
Max. T
250° C
1
d
2
®
1
2
R 300 W/60 C
reference
A
l
r
focal plane
Max. T
350°C
P
B
XBO R 300 W/60 C
(69167)
300
200…310
16 (proper polarity to be observed)
14…19
approx. 6,200
CRI
max. 30
max. 80
max. 30
max. 62
max. Ø 82.5
Ø 31
Ø 23
approx. 120 mm long cables terminated with AMP-plug no.
350809-1, with AMP-pins no. 926868-3
60
W
beam
light
d
D
W
W
A
A
K
>95
deg
mm
mm
mm
mm
mm
mm
mm
XBO R 300 W/60 C
(NAED 69167)
Xenon Short Arc Lamp
Focusing elliptical reflector
Dichroic coating for IR reduction
Ozone-free quartz glass
Hot restrikeable

Related parts for XBO R 300 W/60C OFR

XBO R 300 W/60C OFR Summary of contents

Page 1

Product Information Bulletin ® XBO R 300 W/60 C Xenon Short Arc Lamp Max 250° C reference Technical Data Lamp / order reference (Product ordering number) Electrical data: Rated lamp wattage Power ...

Page 2

... Reference wattage Maximum allowed wattage Minimum allowed wattage Requirements for power supplies Minimum open circuit voltage for power supplies without booster circuit For ignition of cold lamps For ignition of cold or hot lamps 10/2004 1,000 Forced cooling min. 1,450 Ø • min. 2,500 Ø • ...

Page 3

... Zmin T s Zmin Disposal When disposing of spent lamps, always consult federal, state, local and provincial hazardous waste disposal rules and regulations to ensure proper disposal. °C max. 250 allowed; 175 - 200 optimum °C max. 350 allowed; 200 - 250 optimum Forced cooling required, air flow velocity and ...

Page 4

... The above suggested scheme represents just one possible solution. Any other cooling scheme can be applied as long as the temperature limits are not exceeded. Actual temperatures can be measured with a lamp fitted with thermocouples. Lamps with thermocouples are available on request. 380 ...

Page 5

FO140 R2 BEAM PROFILE AT WORKING DISTANCE -1.5 -1 -0.5 0 0.5 mm TYPICAL MAINTENANCE THROUGH 3 mm ROUND APERTURE AT WORKING DISTANCE 300 400 500 600 Operation time (h) ...

Page 6

... A suitable fixture is one that will prevent the arc from being viewed directly while operating ventilated to the outside for those lamps that produce ozone and, in the event of a rupture, will prevent hot (up to 800°C), flying fragments of quartz and/or glass or metal from escaping into the surrounding area. ...

Page 7

... See special handling instructions for using OSHA-approved safety equipment with high-pressure lamps. 2. Lamp should be placed in the original OSRAM SYLVANIA packaging for temporary storage until disposal and/or transportation to a disposal location. See “Lamp Disposal” section below for transportation and spent lamp disposal information ...

Page 8

... Lamp users may obtain information concerning relevant agencies and disposal regulations from the Federal Superfund Hotline (Resource Conservation & Recovery Act) at 800-424-9346. Information may be available as to the appropriate state agencies to contact regarding disposal issues. 4. OSRAM SYLVANIA INC. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities. OSRAM SYLVANIA National Customer Support Center 18725 N ...

Related keywords