LINEAR/470/OS/LM01A/B OSRAM SYLVANIA, LINEAR/470/OS/LM01A/B Datasheet - Page 4

LED MODULE, 32 LED, BLUE, 10LM

LINEAR/470/OS/LM01A/B

Manufacturer Part Number
LINEAR/470/OS/LM01A/B
Description
LED MODULE, 32 LED, BLUE, 10LM
Manufacturer
OSRAM SYLVANIA
Datasheet

Specifications of LINEAR/470/OS/LM01A/B

Led Module Type
Board + LED + Connector
Led Color
Blue
Wavelength Typ
469nm
Luminous Flux @ Test
10lm
Supply Voltage
10.5V
Forward Current @ Test
400mA
Power Rating
4.2W
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Safety Information
Assembly Information
SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc.
OSRAM and OPTOTRONIC are registered trademarks of OSRAM GmbH.
Specifications subject to change without notice.
10. For application involving exposure to humidity and dust the module must be protected by a fixture or housing with a
1. The LED module itself and all its components must not be mechanically stressed.
2. Assembly must not damage or destroy conducting paths on the circuit board.
3. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and
4. Correct electrical polarity needs to be observed. Wrong polarity will result in no light emission and may destroy the
5. A maximum of 3 Modules can be installed consecutively from any power feed. Operation with more than 3
6. The LINEARlight can typically survive transient current levels of up to 2 Amps. As a general design precaution, if the
7. Pay attention to standard ESD precautions when installing the module.
8. The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corro-
9. Damage by corrosion will not be honored as a materials defect claim. It is the user’s responsibility to provide suit-
1. Solder connections should only be performed on designated solder pads (marked “10V +/-”). During soldering, do
2. Each module can be separated into submodules of 4 LEDs each by carefully sawing or cutting at the marked lines.
3. For connector information contact SYLVANIA.
4. The mounting of the module is carried out by attaching it at the mounting holes. Mounting screws should be treated
suitable protective covering. The module can be protected against condensation water by treatment with an appro-
priate circuit board grade conformal coating. The conformal coating should have the following features:
module.
LINEARlight modules will reduce photometric performance and exceed the current carrying capacity of the module.
maximum output current of the power supply is more than 2 Amps, fast-blow fuses should be incorporated into the
wiring plan.
sion. The ability to customize the length of the module by cutting at specifically marked points is a key feature of
the product and hence the reason for no factory installed conformal coating. For these reasons, it is recommended
that the user complete all module modifications first (cutting, wiring) and then apply a conformal coating in the final
stages of installation.
able protection against corrosive agents such as moisture and condensation and other harmful elements.
not exceed the maximum soldering time of 10 seconds and the maximum soldering temperature of 260°C.
with synthetic washers to prevent circuit board damage and possible short circuiting.
safety standards. Only qualified personnel should be allowed to perform installations.
The lacquer APL of the company Electrolube http://www.electrolube.com has met the conditions for LINEARlight in
our tests.
The LED module incorporates no protection against short circuits, overload or overheating.
Therefore it is necessary to operate the modules with an electronically stabilized power supply
offering protection against the above mentioned safety risks. OSRAM OPTOTRONIC power sup-
plies are specifically designed with protection features for safe operation. When using power
supplies other than OPTOTRONIC the following basic safety features should be verified in addi-
tion to any other application-specific concerns and local safety codes:
– Optical transparency
– UV-resistance
– thermal expansion matching the thermal expansion of the module 15-30 x 10
– low permeability of steam for all climatic conditions
– resistance against corrosive environment
– Short circuit protection
– Overload protection
– Overheat protection
– Correct output voltage, including consideration for ripple and spikes
^
-6 cm/cm/K
OSRAM SYLVANIA
National Customer
Service and Sales Center
18725 N. Union Street
Westfield, IN 46074 USA
Industrial Commercial
Phone:
Fax:
National Accounts
Phone:
Fax:
OEM/Special Markets
Phone:
Fax:
Display/Optic
Phone:
Fax:
In Canada
OSRAM SYLVANIA LTD
Headquarters
2001 Drew Road
Mississauga, ON L5S 1S4
Industrial Commercial
Phone:
Fax:
Special Markets
Phone:
Fax:
Visit our website: www.sylvania.com
1-800-255-5042
1-800-255-5043
1-800-562-4671
1-800-562-4674
1-800-762-7191
1-800-762-7192
1-888-677-2627
1-800-762-7192
1-800-263-2852
1-800-667-6772
1-800-265-2852
1-800-667-6772

Related parts for LINEAR/470/OS/LM01A/B