ACPL-C790-500E Avago Technologies US Inc., ACPL-C790-500E Datasheet - Page 7

no-image

ACPL-C790-500E

Manufacturer Part Number
ACPL-C790-500E
Description
Precision Iso-Amp, T/R+IEC+LF
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-C790-500E

Amplifier Type
Isolation
Number Of Circuits
1
Output Type
Differential
-3db Bandwidth
200kHz
Current - Input Bias
100nA
Voltage - Input Offset
600µV
Current - Supply
13mA
Current - Output / Channel
11mA
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.268", 6.807mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Slew Rate
-
Gain Bandwidth Product
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-C790-500E
Manufacturer:
ROHM
Quantity:
36 000
Part Number:
ACPL-C790-500E
Manufacturer:
AVAGO
Quantity:
15 460
Part Number:
ACPL-C790-500E
Manufacturer:
ST
0
Company:
Part Number:
ACPL-C790-500E
Quantity:
998
Company:
Part Number:
ACPL-C790-500E
Quantity:
4 500
Notes:
1. All Typical values are under Typical Operating Conditions at T
2. See Definitions section.
3. Gain temperature drift can be normalized and expressed as Temperature Coefficient of Gain (TCG) of –50 ppm/°C.
4. When FSR is exceeded, outputs saturate.
5. Because of the switched-capacitor nature of the input sigma-delta converter, time-averaged values are shown.
6. Under Typical Operating Conditions, part-to-part variation ±0.04 V.
7. Under Typical Operating Conditions, part-to-part variation ±1 dB.
8. Under Typical Operating Conditions, part-to-part variation ±1 dB.
9. Ripple voltage applied to V
10. The input supply current decreases as the differential input voltage (V
Table 8. Package Characteristics
Notes:
1. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 Vrms for 1 second (leakage detection
2. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
3. This is a two-terminal measurement: pins 1–4 are shorted together and pins 5–8 are shorted together.
7
Parameter
Input-Output Momentary
Withstand Voltage
Resistance (Input-Output)
Capacitance (Input-Output)
section.
current limit, I
5-5 Insulation Characteristic Table.
voltage rating. For the continuous voltage rating, refer to the IEC/EN/DIN EN 60747-5-5 insulation characteristics table and your equipment level
safety specification.
I-O
≤ 5 PA). This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/DIN EN 60747-
DD1
with a 0.1 PF bypass capacitor connected; differential amplitude of the ripple outputs measured. See Definitions
Symbol
V
R
C
I-O
ISO
I-O
Min.
5000
Typ.
>10
0.5
A
= 25°C, V
12
IN
DD1
+ – V
Max.
= 5 V, V
IN
–) decreases.
DD2
Unit
Vrms
:
pF
= 3.3 V.
Test Condition
RH < 50%, t = 1 min., T
V
f = 1 MHz
I-O
= 500 V
DC
A
= 25°C
Note
1, 2
3
3

Related parts for ACPL-C790-500E