Page 1
... Wide input current range: I • CMOS/TTL compatible • Guaranteed switching threshold: I • Internal shield for high Common Mode Rejection (CMR) HCPL-7601: 5,000 V/ s (typical HCPL-7611: 15,000 V/ s (typical • High speed: 10 Mbd typical • Guaranteed ac and dc performance over temperature: - • IEC/EN/DIN EN 60747-5-2 approval: V • ...
Page 2
... The world-wide regulatory approval (UL/CSA/IEC/ EN/DIN EN 60747-5-2) will facilitate the acceptance of the end product in international markets. 2 Regulatory Information The HCPL-7601 and HCPL-7611 have been approved by the following organizations: UL Approved under UL 1577, component recognition FILE E55361). IEC/EN/DIN EN 60747-5-2 ...
Page 3
... To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Combination of Option 020 and Option 060 is not available. Example 1: HCPL-7611-560E to order product of 300 mil DIP Gull Wing Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-2 Safety Approval and RoHS compliant. Example 2: HCPL-7601 to order product of 300 mil DIP package in Tube packaging and non RoHS compliant ...
Page 4
Absolute Maximum Ratings (No Derating Required Storage Temperature ....................................................... - +125 C Operating Temperature ..................................................... - +85 C Lead Solder Temperature ................................................... 260 C for 10 s (1.6 mm below seating plane) ...
Page 5
... MAX. 3.56 ± 0.13 (0.140 ± 0.005) PIN ONE 0.76 (0.030) 1.24 (0.049) *TYPE NUMBER FOR: HCPL-7601 = 7601 HCPL-7611 = 7611 Gull Wing Surface Mount Option 300 REFER TO OPTION 300 DATA SHEET FOR MORE INFORMATION. NOTE: FLOATING LEAD PROTRUSION IS 0.5 mm (20 mils) MAX. ...
Page 6
Solder Reflow Temperature Profile 300 PREHEATING RATE 3°C + 1°C/–0.5°C/SEC. REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC. 200 160°C 150°C 140°C 3°C + 1°C/–0.5°C 100 PREHEATING TIME 150° SEC. ROOM TEMPERATURE Note: Non-halide flux should ...
Page 7
... This part may also be used in Pollution Degree 3 environments where the rated mains voltage is 300 V ** Refer to the front of the optocoupler section of the current Optoelectronics Designers Catalog for a more detailed description of IEC/EN/DIN EN 60747-5-2 and other product safety regulations. Insulation Related Specifications Parameter ...
Page 8
Electrical Specifications Over recommended temperature ( unless otherwise specified. (See note 1.) A Parameter Symbol Input Threshold I TH Current High Level Output I OH Current Low Level Output V OL Voltage High Level ...
Page 9
... Delay Skew Output Rise t rise Time (10% - 90%) Output Fall t fall Time (10% - 90%) Common CM HCPL- H Mode 7601 Transient Immunity at HCPL- High Output 7611 Level Common CM HCPL- L Mode 7601 Transient Immunity at HCPL- Low Output 7611 Level *All typicals Min. Typ.* Max. Unit 100 100 ...
Page 10
... Figure 15 accordance with UL and CSA requirements, each optocoupler is proof tested by applying an insulation test voltage 5000 Vrms for one second (leakage detection current limit A). I-O 10. AC performance approximately equivalent to the HCPL- 2601/ 7.5 mA for comparison F purposes 25° -40° 85° ...
Page 11
PULSE GEN INPUT 3 MONITORING NODE 4 GND APPROXIMATELY 15 pF WHICH INCLUDES L PROBE AND STRAY WIRING ...
Page 12
GND PULSE GENERATOR SWITCH ...
Page 13
DRIVE CIRCUIT (MAX.) 2 2N3906** *74LS04 3 *ANY TTL GATE **ANY PNP TRANSITOR 1N4148 (MAX.) *74HC04 *ANY CMOS HC OR HCT GATE CMOS DRIVE CIRCUIT ...