OF-500-M10 FLUKE NETWORKS, OF-500-M10 Datasheet

no-image

OF-500-M10

Manufacturer Part Number
OF-500-M10
Description
FIBER TESTER KIT
Manufacturer
FLUKE NETWORKS
Datasheet

Specifications of OF-500-M10

Kit Contents
62.5µm & 50µm Launch Fibers, 32MB MMC, USB Cable, AC Adapter, Carrying Strap
Rohs Compliant
NA
OptiFiber
Note:
Above specifications are subject to change without notice
General Specifications
Weight
Dimensions
Battery
Battery life
Connections
Memory card
Environmental Specifications
Operating temperature
Non-operating temperature
Relative humidity (%RH operating without
condensation)
Vibration
Shock
Key OTDR
Specs (23°C)
Output/input connector
Wavelengths
Fiber types tested
Event deadzone
Attenuation deadzone
Pulse width
Max distance range
Dynamic range
Testing speed
Output power
Distance accuracy
Loss threshold
Linearity
Sample resolution
Reflectance accuracy
ORL accuracy
Laser classification
Key Power Meter and Loss/Length
Specifications (23°C)
Input/output connectors
Nominal output wavelengths
Measurement range
Power measurment detector type
Calibrated wavelengths for power measurment
Power measurement range
Output power (nominal)
®
Specifications and Ordering Information
Main with module and battery: 4.5 lbs (1.9 kg)
Main with module and battery:
11.4 x 7.5 x 2.5 in (29.0 x 19.1 x 6.4 cm)
Li-Ion
8 hours typical
USB, RS-232, FiberInspector
SD MMC
0°C to 40°C
-20°C to 60°C
95% (10 to 35°C); 75% (35 to 40°C)
Uncontrolled < 10°C
Random, 2 g, 5-500 Hz
1 meter drop test while module is both
inserted inside and outside the instrument enclosure
Multimode:
OFTM-5610B, OFTM-5611B, OFTM-5612B
SC/UPC removeable/cleanable
850 ± 20 nm and 1300 ± 25 nm
50/125 µm or 62.5/125 µm multimode
850 nm: 0.5 m typical
1300 nm: 1.3 m typical
850 nm: 4.5 m typical
1300 nm: 10.5 m typical
850 nm: 4 ns, 20 ns
1300 nm: 8 ns, 40 ns, 100 ns, 200 ns,
400 ns, 650 ns
850 nm: 3 km, 1300 nm: 7 km
850 nm: 15 dB typical
1300 nm: 14 dB typical
<10s for two wavelengths at 2 km with 25 cm resolution
<30s for two wavelengths at 400 m with 3 cm resolution
850 nm: >110 mW-pk
1300 nm: >22 mW-pk
± 1 m ± 0.005% of distance ± 50% of resolution ± IOR error ± event location error
.2 dB
± .07 dB/dB
3 cm to 50 cm
± 4 dB
± 4 dB
Class 1 CDRH, complies to EN 60825-2
OFTM-5612B, OFTM-5732
Removable/interchangeable input connector; SC/PC output connector
OFTM-5612B: LED source: 850 nm and 1300 nm
OFTM-5732: Laser source: 1310 nm and 1550 nm
OFTM-5612B: 5 km of 62.5 µm or 50 µm multimode fiber; 20 km in far-end source mode
OFTM-5732: 10 km of 9 µm singlemode fiber; 60 km in far-end source mode
InGaAs
850 nm, 1310 nm, 1550 nm
0 to -60 dBm (1300/1310 nm and 1550 nm); 0 to -52 dBm (850 nm)
OFTM-5612B: -19.5 dBm; OFTM-5732: -7 dBm
OptiFiber
fiber networks with the most complete fiber optic test solution.
®
Certifying OTDR. Bringing Network SuperVision to premise
TM
camera port, PS-2 keyboard
Singlemode:
OFTM-5730, OFTM-5731, OFTM-5732
SC/UPC removable/cleanable
1310 ± 25 nm and 1550 ± 30 nm
9/125 µm singlemode
1310/1550 nm: 1 m typical
1310/1550 nm: 8 m typical
1310 nm/1550 nm: 5 ns, 20 ns, 40 ns, 100 ns,
300 ns, 1 µs, 3 µs, 10 µs
1310/1550 nm: 60 km
1310 nm: 26 dB typical
1550 nm: 24 dB typical
Auto OTDR 15 seconds typical
Manual OTDR 15 seconds to 3 min
1310 nm: >28 mW-pk
1550 nm: >24 mW-pk
.01 dB to 1.5 dB inclusive
± .05 dB/dB
3 cm to 400 cm
± 4 dB
± 4 dB
OptiFiber Certifying OTDR

OF-500-M10 Summary of contents

Page 1

... IOR error ± event location error .2 dB ± .07 dB/ ± ± ...

Page 2

... Includes contents of OF-500-35 plus: 50 µm launch fiber, 50 µm test reference cords protective carrying case, Smart Remote unit, Smart Remote MM module, Smart Remote carry strap, Smart Remote user guide, Mini-B USB cable, a second AC adapter, ...

Page 3

... Ultimate protection for the mainframe, modules, batteries and accessories Enter information quickly with the plug and play keyboard Record storage Easily keep track of your MMC cards in this handy case that stores MMC cards Upload saved results to the PC for results management, analysis and reporting ...

Page 4

... OptiFiber Options and Accessories Ordering Information Model Description NFA-LC LC connector adapters for OFTM Power Meter and DTX Module inputs, set of two NFA-ST ST connector adapters for OFTM Power Meter and DTX Module inputs, set of two NFA-FC FC connector adapters for OFTM Power Meter ...