DPO4034B Tektronix, DPO4034B Datasheet - Page 14

no-image

DPO4034B

Manufacturer Part Number
DPO4034B
Description
OSCILLOSCOPE, 4 CHANNEL, 350MHZ, 2.5GSPS
Manufacturer
Tektronix
Type
Mixed Signalr
Datasheet

Specifications of DPO4034B

Scope Type
Digital Bench
Scope Channels
4 Analog
Bandwidth
350MHz
Meter Display Type
XGA LCD
Sampling Rate
2.5GSPS
Input Impedance
1Mohm
Rise Time
1ns
Input Voltage
250Vrms
Configuration
Benchtop
Number Of Channels
4
Sample Rate
2.5 GS/s
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Data Sheet
Acquisition Modes
Mode
Sample
Peak Detect
Averaging
Envelope
Hi Res
Roll
Waveform Measurements
Measurement
Cursors
Automatic
Measurements
Measurement
Statistics
Reference Levels
Gating
Waveform Histogram
Waveform Histogram
Measurements
14
Mode
I
(Optional)
Parallel (Available on
MSO models only)
2
S/LJ/RJ/TDM
www.tektronix.com
Description
Trigger on Word Select, Frame Sync, or Data. Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a specific data value, or inside or outside of
a range
Maximum data rate for I
Maximum data rate for TDM is 25 Mb/s
Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits in size. Binary and Hex radices are supported
Description
Description
Acquire sampled values
Captures glitches as narrow as 800 ps (1 GHz
models) or 1.6 ns (500 MHz and 350 MHz models)
at all sweep speeds
From 2 to 512 waveforms included in average
Min-Max envelope reflecting Peak Detect data over
multiple acquisitions
Real-time boxcar averaging reduces random noise
and increases vertical resolution
Scrolls waveforms right to left across the screen at
sweep speeds slower than or equal to 40 ms/div
Waveform and Screen
29, of which up to four can be displayed on-screen
at any one time. Measurements include: Period,
Frequency, Delay, Rise Time, Fall Time, Positive
Duty Cycle, Negative Duty Cycle, Positive Pulse
Width, Negative Pulse Width, Burst Width,
Phase, Positive Overshoot, Negative Overshoot,
Peak-to-Peak, Amplitude, High, Low, Max, Min,
Mean, Cycle Mean, RMS, Cycle RMS, Positive
Pulse Count, Negative Pulse Count, Rising Edge
Count, Falling Edge Count, Area and Cycle Area
Mean, Min, Max, Standard Deviation
User-definable reference levels for automatic
measurements can be specified in either percent
or units
Isolate the specific occurrence within an acquisition
to take measurements on, using either the screen
or waveform cursors
A waveform histogram provides an array of data
values representing the total number of hits
inside of a user-defined region of the display. A
waveform histogram is both a visual graph of the
hit distribution as well as a numeric array of values
that can be measured.
Sources – Channel 1, Channel 2, Channel 3,
Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math
Types – Vertical, Horizontal
Waveform Count, Hits in Box, Peak Hits, Median,
Max, Min, Peak-to-Peak, Mean, Standard
Deviation, Sigma 1, Sigma 2, Sigma 3
2
S/LJ/RJ is 12.5 Mb/s
Waveform Math
Characteristic
Arithmetic
Math Functions
FFT
Advanced Math
Power Measurements (Optional)
Measurement
Power Quality
Measurements
Switching Loss
Measurements
Harmonics
Ripple
Measurements
Modulation Analysis
Safe Operating Area
dV/dt and dI/dt
Measurements
Description
Add, subtract, multiply, and divide waveforms
Integrate, Differentiate, FFT
Spectral magnitude
FFT Vertical Scale: Linear RMS or dBV RMS
FFT Window Settings: Rectangular, Hamming,
Hanning, Blackman Harris
Define extensive algebraic expressions including
waveforms, reference waveforms, math functions.
Perform math on math using complex equations
(FFT, Intg, Diff, Log, Exp, Sqrt, Abs, Sine,
Cosine, Tangent, Rad, Deg), scalars, up to two
user-adjustable variables and results of parametric
measurements (Period, Freq, Delay, Rise,
Fall, PosWidth, NegWidth, BurstWidth, Phase,
PosDutyCycle, NegDutyCycle, PosOverShoot,
NegOverShoot, PeakPeak, Amplitude, RMS,
CycleRMS, High, Low, Max, Min, Mean,
CycleMean, Area, CycleArea, and trend plots)
e.g. (Intg(Ch1–Mean(Ch1))×1.414×VAR1)
Description
V
Power, Apparent Power, Reactive Power, Power
Factor, Phase Angle
Power Loss: T
Energy Loss: T
THD-F, THD-R, RMS measurements
Graphical and table displays of harmonics
Test to IEC61000-3-2 Class A and MIL-STD-1399
V
Graphical display of +Pulse Width, –Pulse Width,
Period, Frequency, +Duty Cycle, and –Duty Cycle
modulation types
Graphical display and mask testing of switching
device safe operating area measurements
Cursor measurements of slew rate
RMS
ripple
, V
and I
Crest Factor
ripple
on
, Frequency, I
on
, T
, T
off
off
, Conduction, Total
, Conduction, Total
RMS
, I
Crest Factor
, True