FLUKE-192C/003 Fluke, FLUKE-192C/003 Datasheet - Page 3

no-image

FLUKE-192C/003

Manufacturer Part Number
FLUKE-192C/003
Description
SCOPE METER, 60MHZ, 2 CHANNEL, 500MSPS
Manufacturer
Fluke
Type
Digitalr
Datasheet

Specifications of FLUKE-192C/003

Scope Type
Digital Hand Held
Scope Channels
2
Bandwidth
60MHz
Meter Display Type
LCD Monochrome
Sampling Rate
500MSPS
Input Impedance
1Mohm
Rise Time
5.8ns
Input Voltage
1kV
Brand/series
ScopeMeter®/190 Series
Configuration
Handheld
Display Type
Color
Memory
3 Kpts
Sample Rate
0.5 GS/s
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Zoom
Up to 16x horizontal zoom
Bus health test mode
(Fluke 225C and 215C only)
Bus Health automatically analyzes the electrical signals
on the industrial bus system to measure individual
parameters and to give waveform information.
Automatically compares the measurement results to
preset values and present ‘good’, ‘weak’ or ’false’
indicator with each parameter.
Bus types and reference standards used:
AS-i (EN50295, 166 kb/s);
CAN-bus (ISO-11898, up to 1 Mb/s);
Modbus (EIA-232 up to 115 kb/s and EIA-485
up to 10 Mb/s);
Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s);
Profibus DP (EIA-485 up to 10 Mb/s) and PA (61158
type 1, 31.25 kb/s);
Ethernet [10Base2 (coaxial) and 10BaseT (UTP)],
10 Mb/s;
Ethernet 100BaseT (100 Mb/s);
RS-232 (EIA-232, up to 115 kb/s);
RS-485 (EIA-485, up to 10 Mb/s).
Measured parameters (where applicable):
Bias voltage level, signal amplitude, pulse width or
baud rate, risetime, fall time, jitter, signal distortion,
noise HF, noise LF, in-band noise.
Recorder mode
ScopeRecord—roll mode
Dual input waveform storage mode
Source and display: Input A, input B, dual
Memory depth: 27,500 points per input. Each point
consists of Min-Max pair
Min-Max values: Min-Max values are measured at
high sample rates ensuring capture and display of
glitches
Recording modes: Single sweep, continuous roll,
Start-on-Trigger (through external), Stop-on-Trigger
(through external)
Stop-on-Trigger (through external): ScopeRecord
mode can be stopped by an individual trigger event, or
by an interruption of a repetitive trigger signal
Horizontal scale: Time from start, time of day
Zoom: Up to 100x
Memory: Up to 2 dual input ScopeRecord waveforms
can be saved for later recall and analysis
TrendPlot
Single or dual input electronic paperless chart
recorder. Plots, displays and stores meter and scope
measurements.
Source and display: Input A, input B or DMM input
Memory depth: 18,000 points recording. Per record
point a minimum, a maximum and an average value,
plus a date and timestamp are recorded.
Ranges: 5 s/div to 30 min/div in normal view mode;
5 min/div to 48 hr/div in view all mode, giving
overview of total record
Time base range
Recorded timespan
Glitch capture
Sample rate
Resolution
recording
5 ms/div to 1 min/div
200 μsec to 2 sec
6 sec to 24 hr
20 MS/s
50 ns
2 min/div
4.8 sec
250 ns
4 MS/s
48 hr
Recorded timespan: Up to 22 days with a resolution
of 1 minute
Recording mode: Continuous roll for the duration of
the full recordable timespan
Measurement speed: 5 measurements per second
Horizontal scale: Time from start, time of day
Zoom: Up to 64x zoom
Memory: Up to 2 TrendPlot recordings can be saved
for later recall and analysis
Cursor measurements—all recorder modes
Source: Input A, B or DMM input
Dual vertical lines: Min-Max or Average
voltage. Time between cursors
Single vertical line: Min-Max or Average
voltage. Absolute date and time or time from start
Meter mode
Via 4 mm banana inputs. Fully isolated from scope
inputs and scope ground. The specified accuracy is
valid over the temperature range 18 °C to 28 °C
(65 °F to 82 °F). Add 10 % of specified accuracy for
each degree C below 18 °C or above 28 °C.
Maximum resolution: 5,000 counts
Voltmeter ranges: 500 mV, 5 V, 50 V, 500 V, 1,000 V
Accuracy:
Ohms:
Other meter functions
Continuity: Beeper on < 50 W (± 30 W)
Diode test: Up to 2.8 V
Amps: A dc, A ac, A ac+dc using an optional current
clamp or shunt. Scaling factors: 0.1 mV/A ... 100 V/A
Temperature (°C, °F): With optional accessories. Scale
factors 1 mV/°C or 1 mV/°F
Input impedance: 1 MW ± 1 %/10 pF ± 2 pF
Advanced meter functions: Auto/manual ranging,
relative measurements (zero reference), TrendPlot
recording
General specifications
Input voltage ratings
Maximum probe voltage: CAT II 1,000 V, CAT III
600 V (Maximum voltage between 10:1 probe tip
(VPS210) and reference lead)
Floating voltage: CAT II 1,000V, CAT III 600 V
(Maximum voltage between earth ground and any
terminal (signal input or shielding))
Independently isolated inputs: CAT II 1,000 V,
CAT III 600 V (Maximum voltage between any terminal
of one input or probe (VPS210) and any other terminal
of another input or probe (VPS210))
Maximum voltage on BNC input directly
(input A or B): CAT III 300 V
Maximum voltage on meter input: CAT II 1,000 V,
CAT III 600 V
V dc ± (0.5 % + 5 counts)
V ac true rms
V ac+dc true rms
Ranges: 500 W, 5 kW, 50 kW, 500 kW, 5 MW, 30 MW
Accuracy: ± (0.6 % + 5 counts)
15 Hz to 60 Hz: ± (1 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
dc to 60 Hz: ± (1 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
ScopeMeter 215C, 225C and 190C Series, 120 Series
Fluke Corporation 3