EI-162BN Fluke, EI-162BN Datasheet

SPLIT-CORE TRANSFORMER

EI-162BN

Manufacturer Part Number
EI-162BN
Description
SPLIT-CORE TRANSFORMER
Manufacturer
Fluke
Datasheets

Specifications of EI-162BN

External Height
46cm
External Width
36cm
External Depth
16cm
Weight
17.6lb
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
The new Fluke 1623 and 1625
GEO Earth Ground Testers offer
an innovative solution, called
Stakeless testing, to make your
earth ground loop resistance
testing quicker and easier. No
need for a separate earth
ground clamp.
In addition, the Fluke 1625 offers
these advanced features:
Fluke 1623 and 1625
3- and 4-pole Fall of Potential,
earth resistance loop testing
4-pole Soil Resistivity testing
Selective earth ground rod
testing using 1 clamp
Stakeless earth ground rod
testing using 2 clamps
IP56 rated for outdoor use
Rugged carrying case
Automatic Frequency Control
(AFC) - identifies existing
interference and chooses a
measurement frequency to
minimize its effect, providing
more accurate earth ground
value
R* measurement - calculates
earth ground impedance at
55 Hz to more accurately
reflect the earth ground
resistance that a fault-to-
earth ground would see
Adjustable limits - for quicker
testing
GEO Earth Ground Testers
Stakeless testing
The Fluke 1623 and 1625 earth
ground testers are able to measure
earth ground loop resistances using
only clamps. With this test method,
two clamps are placed around the
earth ground rod and each are con-
nected to the tester. No earth ground
stakes are used at all. A known, fixed
voltage is induced by one clamp and
the current is measured using the
second clamp. Then the tester auto-
matically determines the resistance
of the earth ground rod.
bonded earth ground system exists for
This test method only works if a
the building or structure under test, but
most are. If there is only one path to
ground, like at many residential appli-
cations, the Stakeless method will not
provide an acceptable value and the Fall
of Potential test method must be used.
ground rod does not need to be dis-
connected—leaving the bonded earth
ground system intact during test. Gone
are the days of spending time placing
and connecting stakes for each earth
ground rod on your system—a major
time saver. You can also perform earth
ground tests in places you’ve not
considered before: inside buildings,
power pylons, or anywhere you don’t
have access to soil.
With Stakeless testing, the earth
Technical Data

EI-162BN Summary of contents

Page 1

... Adjustable limits - for quicker testing Stakeless testing The Fluke 1623 and 1625 earth ground testers are able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are con- nected to the tester ...

Page 2

... C1 (IEC 654-1), -5 °C to +45 °C (23° to +115° F Protective type IP56 for case, IP40 for battery door according to EN60529 Safety Protection by double and/or reinforced insulation. max earth EMC (Emission Immunity) IEC 61326-1:1997 Class A Quality system Developed, designed and manufactured according to DIN ISO 9001 External voltage V ext, max = 24 V (dc, ac < ...

Page 3

... H Monitoring and R with error indicator S H Automatic range selection Measurement is not performed if the current through the current clamp is too low 3 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Measuring range Intrinsic error 0.001 Ω to 19.99 kΩ ± rdg + > 128 Hz (125 Hz on request) Max 100 kΩ ...

Page 4

... EXT Automatic range selection The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified. 4 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Measuring range Intrinsic error 0.001 Ω to 19.99 kΩ ...

Page 5

... Fluke Corporation 1623 and 1625 GEO Earth Ground Testers -10 ° ...

Page 6

... With IEC LR6/type AA : typ. 6,000 measurements (R 250 mm x 133 mm x 187 mm (9. 5. 7.35 in) Dimensions (WxHxD) ≤ 1.1 kg (2.43 lb) without accessories Weight ≤ 5.5 kg (12.13 lb) incl. accessories and batteries in carrying case Case material NORYL, shock -and scratch proof thermoplast Measurement of interference voltage ...

Page 7

... Automatic check if error is kept within the limits required by IEC61557-5. If after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than assumed because of the influencing conditions (see diagram), the display shows a warning symbol 7 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Designation ...

Page 8

... Additonal error because of probe- and auxiliary earth typ. electrode resistance Measuring error of R and Measuring time Minimal current in single branch to be measured Max. interference current through transformer 8 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Resolution 1 mΩ 10 mΩ 100 mΩ 1 Ω ...

Page 9

... R K Formation of measured value R display = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment. * Value of setpoint entry Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Resolution 0.001 Ω ± rdg + 2 digit) 0.01 Ω 0.1 Ω 1 Ω ...

Page 10

... Stake Set for 4-Pole Measurement Earth Stake Ground/Earth Stake Cable-Reel 25 m Ground/Earth Cable Reel 25 m (81.25 ft) Cable-Reel 50 m Ground/Earth Cable Reel 50 m (162.5 ft) EI-162BN 320 mm (12.6 in) Split Core Transformer 10 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Industrial Power Utilities and Telecom • ...